Page History
To display the Work with Display and Print Controls screen, select Administration from the Main System Menu (Advanced), choose Review system settings from the Administration Menu and then select Display and print controls from the Review of System Settings menu.
DC@P8118 Work with Display and Print Controls
|
Popup window to trim second function key line . : Y
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
The Work with Display and Print Controls settings are retrieved from the data areas.
Setting | DC@A01 | DC@A07 | DC@OSVEROP |
|---|---|---|---|
Prompt key | 477 | ||
Decimal format | 494 | ||
Leading zero | *LEADZERO=1 | ||
Popup window | *V2WINDOWS | ||
Popup trim | *WINDOWTRIM | ||
Printer width | 149-151 | ||
Printer length | 412-414 | ||
Printer overflow | 415-417 | ||
Default STD_HEAD | 421 | ||
Vertical bar character | 484 | ||
Horizontal bar character | 485 | ||
Field label fill | 463 | ||
Field column underline | 464 | ||
Hex for 132 widthworkstation | 441-460 | ||
Hex for color workstation | 465-474 |
Default for enable prompt key on screen commands
Position 477 in data area DC@A01.
If this value is set to "Y", the PROMPT_KEY parameter on DISPLAY, REQUEST and POP_UP RDML commands will be enabled by default. If set to "N" the prompt key is disabled by default. The default may be specifically changed for individual commands in your RDML code.
LANSA decimal point format
Position 494 in data area DC@A01.
...
| Warning |
|---|
| Warning: If the value of this field does not relate to the value of QDECFMT then unpredictable results could occur with the use of numeric values. |
Show a leading zero
Setting *LEADZERO=1 in data area DC@OSVEROP.
Setting this value to "Y" indicates that Visual LANSA code will display numeric values containing decimals with a leading zero. For example 0.12 or 0,12 depending on the LANSA decimal point format. This option would be suitable when QDECFMT="J".
Popup window to use IBM i window facility
Setting *V2WINDOWS in data area DC@OSVEROP.
Setting this value to "Y" indicates that pop-up windows created by LANSA should use the operating system windowing facilities. The use of the option is recommended on all IBM i systems.
Popup window to trim second function key line
Setting *WINDOWTRIM in data area DC@OSVEROP.
...
Only use this option in conjunction with the *V2WINDOWS option to enable existing functions that have been specifically sized onto line 24 of the display device to recompile without change.
Use default STD_HEAD parameters
Position 421 in data area DC@A01.
...
STD_HEAD parameter on screen commands specifies whether or not the standard LANSA design for the screen heading lines (lines 1 and 2) should be used.
Printer form width default
Positions 149 - 151 in data area DC@A01.
This value specifies the default printer form width. Typically 132.
Printer form length default
Positions 412 - 414 in data area DC@A01.
This value specifies the default printer form length (RPG limit). Typically 66.
Printer overflow line default
Positions 415 - 417 in data area DC@A01.
This value specifies the default printer form overflow line (RPG limit). Typically 60.
Vertical bar character
Position 484 in data area DC@A01.
This value specifies the vertical bar character to be used on reports such as RDML listings. If this value is left as blank (X'40') it defaults to ":" (X'6A'). This option may not be suitable for some national language sets and should be changed.
Horizontal bar character
Position 485 in data area DC@A01.
Horizontal bar character to be used on reports such as RDML listings. If this value is left as blank (X'40') it defaults to "-" (X'60'). This option may not be suitable for some national language sets and should be changed.
Field label fill character
Position 463 in data area DC@A01.
...
| Note |
|---|
| Note: Recompilation is necessary for changes to this setting to take effect. |
Field column heading underline character
Position 464 in data area DC@A01.
...
| Note |
|---|
| Note: Recompilation is necessary for changes to this setting to take effect. |
Hex code for 132 width workstations
Positions 441 - 460 in data area DC@A01.
...
This is only used by the report painter to aid the user design report layouts. Refer to the appropriate IBM manual for list of codes.
Hex code for color workstations
Positions 465 - 474 in data area DC@A01.
...