Page History
...
How to display the NetFlow dashboard using IE /var/adm/messages kernel: cdrom: open failed
Suppress Connection Warnings from the Agent in /var/adm/messages Monitor Disk Mounting in Active / Passive Cluster Nodes Anchor
Edit the uptimeagent or uptmagnt file under /etc/xinetd.d and add the following lines between the {} characters: log_on_success -= PID
log_on_success -= EXIT log_on_success -= HOST DURATION log_on_failure -= HOST
Restart the xinetd process.
To test if the agent is still logging messages, run a tail -f on messages and then poll the Agent from the Uptime Infrastructure Monitor user interface to see if this action logs a new message.
This scenario would potentially produce a report of the same data that shows different values depending on the report timeframe. For example: Configuration Changes
Change Detected Change Description
2010-01-27 15:04:43 Memory size changed from 18874368kB to 4194304kB 2010-01-27 11:18:54 Memory size changed from 4194304kB to 18874368kB 2010-01-27 09:15:01 Memory size changed from 18874368kB to 4194304kB 2010-01-27 06:47:17 Memory size changed from 4194304kB to 18874368kB
If we were to run a report on Jan 27 for the system with the above configuration changes, we would see that some reports show memory at 18 Gb, some at 4 Gb and the average as n/a.