Page History
Changing the port using the Agent Console
- Locate and run the UIM Agent Console under the Start menu on the target server.
- In the application window, update the Port field to the new desired port.
- Click Save.
- Click Restart to restart the agent and apply the settings.
Info If you already added the server to UIM for monitoring, you must also update the agent port in the UIM web interface.
Changing the port manually
- Start the Windows Registry Editor by selecting Run from the Start Menu, typing regedit in the Open field of the Run dialog box, and then clicking OK.
- Find the following registry key:
HKEY_LOCAL_MACHINE/SOFTWARE/UptimeSoftware/up.time agent
For older agents, this key may be named:HKEY_LOCAL_MACHINE/SOFTWARE/UptimeSoftware/up.time NT agent
- Change the value in the Port field to the desired port.
- Stop and start the Windows agent by selecting Run from the Start Menu, typing regedit in the Open field of the Run dialog box:
net stop "up.time agent"
net start "up.time agent"
For older agents, the agent service name is up.time NT agent.