Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Problem

:I am using Internet Explorer to access Uptime, and have enabled up.time NetFlow integration. However, the NetFlow dashboard only partially displays my Scrutinizer UI.

Solution

:Enable third-party cookies in Internet Explorer.

As of version 11, Scrutinizer uses cookies as part of its login process. When accessing Scrutinizer through Uptime's NetFlow dashboard, these cookies will be treated as third-party. Internet Explorer, by default, rejects third-party cookies.

To enable third-party cookies in supported versions of Internet Explorer, do the following:

  1. Click Tools, and then click Internet Options.
  2. Click the Privacy tab.
  3. Click Advanced.
  4. Select the Override automatic cookie handling check box.
  5. For Third-party Cookies, select the Accept option.
  6. Click Done.

Related Documentation:

For more information, see Integrating Scrutinizer with Uptime Infrastructure Monitor and Platform Support and Integration Changes in 7.3Take the following steps for each agent system that you would like to exclude file systems from:  Browse to the element using My Infrastructure.
 Under the element's Info sub-tab, click Info & Rescan and then Edit Performance Monitor in the main panel.
 Use the Worst Disk Usage Exclusion and Inclusion fields to eliminate (or specifically add) file systems to be included in the Worst Disk Used column of the GlobalScan page for this element.
 Click Save.
After completing this process, review the GlobalScan page to verify the changes. Note that the values will not be updated until the next time the agent is polled for performance data.