You can manually configure these parameters according to the requirements of your environment. You can edit the default values or override them by defining instance-specific values. If a process does not include any configurable parameters, the Parameters button is disabled. See “About About configurable process parameters” on page 87parameters.

The following table lists all the processes that you can configure per monitored instance.

...

  1. In the Main area table, select the process whose parameters you want to configure.
  2. Click Parameters.
  3. In the Parameters dialog box, perform one of the following actions:

    To edit the default values for the selected technology

    Click Edit Default Values.

    In the Default Values dialog box, specify the values and click OK.

    Unless instance-specific values override these values, they apply to all monitored instances.

    To edit the values for a specific instance

    Select an instance in the table. Click Edit.

    In the Edit Instance dialog box, clear the Use Defaults check box. Specify the values to be used for this instance.

    Click OK.

  4. In the Parameters dialog box, click OK.

    Info

    After you change the default of the Minimum In Oracle time to load parameter in the Load Data process, you must stop and then restart the Precise for Oracle FocalPoint. The next step is to restart the Collector agents.

    Info

    Changing the “Load Data” value from “300” to “30” for Precise for J2EE can take up to ten minutes to take effect.

    Info

    You can also configure the Precise for Web URL mapping rule for a domain in a system: “Treat "Treat pages with different titles as different pages”pages." Select to view the URL along with the various titles that belong to it. The collected data includes page URLs and page titles. When cleared, you can only differentiate between different URLs, not between page titles. In this case, the collected data includes the page URL and the first page title for any URL in the system.

...

Most process are specific to one technology. The “Load Data” Load Data process that does not have a Technology value is shared by SmartLink and J2EE. All changes to this value affect the slice size not only in SmartLink tabs, but also in all J2EE instances in that environment.

...

  1. Go to AdminPoint>Warehouse>Processes.
  2. From the table, select the “Load Data” Load Data process with an empty Technology value. Click Parameters.
  3. Select the relevant environment and click Edit.
  4. Mark the “Use Defaults” Use Defaults check box to enable editing.
  5. From the drop-down menu, select the desired slice size.
  6. Click OK>OK.

    Info

    Changing the “Load Data” Load Data value from “300” to “30” may take up to ten 10 minutes to take affect in Precise for J2EE.

...

  1. Select an instance in the Main area table and click Processes.
  2. In the PMDB Processes dialog box, the top table lists all processes involved in loading information for this instance. Select the process you want to focus on, such as a process that failed during its last run (indicated by the status icon).
    The last run of this process affects the bottom table populated with detailed information on the PMDB tables. If an error occurred, focus on the details in the Error Message column.
  3. Investigate all relevant data. Then click Close.

...