Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

1.   Look for an X_ERR.LOG. This will be written to the path defined by the X_RUN parameter TPTH. The default value for this path is the user's temporary folder which can be found using the shortcut %TEMP% for the path. You should refer to the Technical Reference guide for more information on how this path is evaluated. One or more of the following log files may be found:
      MSIxxx.log
      DPinstal.log
      LANSAInstallLog.txt
      LANSAInstallPermissions.txt
      X_err.log
      Import.log
      InstallTrace.txt (requires x_run parameter ITRO=Y. This may be set globally in a Windows environment variable)

...

3.   Turn on tracing in the LANSA application. Application level tracing is enabled by the X_RUN parameter ITRO=Y.

Turn on Tracing for the LANSA Listener.

The Communications Administration program (lcoadm32.exe) is installed to the Windows server application's \connect folder.

1a.   For Windows 7, look in the Windows Start menu under your company name and application name.  Double click on the Communications Administrator program.

Image Modified

1b.   For Windows 8, use Search to find Communications Administrator, use the context menu to Run as Administrator.

2.   Select Listener from the Advanced menu

WorF6Image Modified

a.   Click the Log and Trace button.

Wor385EImage Modified

b.   Use the Select All button to show all trace options selected, as shown in the screen capture above. You should refer to the LANSA Communications Setup Guide for detailed recommendations.

c.   Click OK to close the Log and Trace Information dialog.

d.   Use the Stop Listener button to stop and the start the listener.

Wor369BImage Modified

3.   Run your client application to connect to the Windows Server application. Then examine the trace file which is produced. The listener trace file (lroute.trc) is written to the \connect folder in the Windows server application folder. For example:
C:\Program Files (x86)\<company name>\<application name>\Connect

Turn on Application Level Tracing

The X_RUN parameter can most easily be set by defining an environment variable or by adding the parameter to the LANSA profile file (x_lansa.pro).

...

2.   Open the x_lansa.pro file with Notepad.

Wor705DImage Modified

3.   Add an ITRO=Y parameter.

4.   Optionally add a TPTH=c:\temp parameter, using any suitable folder name. The default path is the user's Windows temporary folder path (%TEMP%).

...