Page History
...
Info |
---|
This document describes the procedure when upgrading to Precise 9.7.0. You must first upgrade to version 9.6.0, 9.6.1, 9.6.2, 9.6.3, or 9.6.4 before attempting to upgrade to version 9.7.0. Therefore, if you are upgrading from an earlier Precise installation, see the relevant Upgrade Guide, or if you are installing Precise 9.7.0 on a clean system, see instead the Precise Installation Guide. |
About the upgrade to Precise 9.7.0
Updating to Precise 9.7.0 both updates the existing Precise Framework and agents and replaces the previously existing Precise system, while preserving the previously captured monitored data. As a result, the upgrade process involves downtime of the Precise product.
...
Once all preparations have been completed, perform the update, as detailed in Performing the upgrade.
Changes in the Precise for Web logic
In version 9.6.1, we made changes in Precise for Web logic with regard to the Collector settings. They were changed from Domain related to Instance and Cluster related.
...
The maximum amount of entries in the Exceptions table is 15.
Changes in the Precise for Web configuration
In version 9.6.1, the User-defined configuration changed. We no longer support User Defined 1 and User Defined 2. If you defined them in a previous version and you want to keep using them, you may need to redefine the User Defined 1 and 2 as User Defined Transaction Name. It is also possible that the definition can no longer be used.
Changes in supported platforms
In version 9.6.1, Precise for Tuxedo is no longer supported. If you start the update process and Precise for Tuxedo is detected, you get the following error message:
...
Uninstall Precise for Tuxedo in the indicated environments and restart the update or refrain from upgrading to Precise 9.6.1 or later.
Discovering any integrity issues when upgrading
Info |
---|
The upgrade to version 9.7.0 can be done only from version 9.6.0, 9.6.1, 9.6.2, 9.6.3, or 9.6.4. |
...
Trying to upgrade prior to successful completion of this utility will fail.
Using the Precise Upgrade Verifier Utility
- Download the utility.
- Place UpgradeTo9xxVerifier-<latest date>.zip in the Precise root directory on the MAIN Precise FocalPoint server
- Extract/unzip the UpgradeTo9xxVerifier-<latest date>.zip file into the Precise root directory or extract the files, then move them to the Precise root directory
Execute the verifier:
On Windows:
(Rename UpgradeTo9xxVerifier.bat.txt to UpgradeTo9xxVerifier.bat)
UpgradeTo9xxVerifier.bat
On UNIX:
(Make sure the UpgradeTo9xxVerifier.sh has 'execute' permissions)
./UpgradeTo9xxVerifier.shInfo Log file with the output of the utility will be written to: <Precise root>\logs\infra.pre_upgrade_sanity.out.