Configuration OIDs Troubleshooting with snmpwalk

Below is the list of the OIDs used to collect configuration data and performance metrics related to Network Device elements in Uptime Infrastructure Monitor.

Configuration OIDs

These configuration information OIDs are collected when the Network Device is added to Uptime Infrastructure Monitor and updated regularly by the Configuration Update Gatherer which rescans every 24 hours.

OID

MIB

Name

Mandatory

1.3.6.1.2.1.1.5.0

RFC1213-MIB

System Name

Yes

1.3.6.1.2.1.1.1.0

RFC1213-MIB

System Description

Yes

1.3.6.1.2.1.1.4.0

RFC1213-MIB

System Contact

No

1.3.6.1.2.1.1.6.0

RFC1213-MIB

System Location

No

1.3.6.1.2.1.31.1.1

IF-MIB

Interface Table

Yes

1.3.6.1.2.1.2.2.1.1

RFC1213-MIB

Port Index

Yes

1.3.6.1.2.1.31.1.1.1.1

IF-MIB

Port Name

Yes - If unavailable, 1.3.6.1.2.1.2.2.1.1 (RFC1213-MIB) will be used instead

1.3.6.1.2.1.2.2.1.2

RFC1213-MIB

Port Description

No

1.3.6.1.2.1.2.2.1.3

RFC1213-MIB

Port Type

Yes

1.3.6.1.2.1.2.2.1.7

RFC1213-MIB

Port Admin Status

Yes

1.3.6.1.2.1.2.2.1.8

RFC1213-MIB

Port Operational Status

Yes

1.3.6.1.2.1.2.2.1.5

RFC1213-MIB

Port Speed

Yes

1.3.6.1.2.1.2.2.1.6

RFC1213-MIB

Port MAC

Yes




Performance Metric OIDs

Performance metrics are only collected for Network Devices that are switches or routers added in Uptime Infrastructure Monitor. Metrics will be gathered for ports that have "Port Admin Status" as up and have a valid speed value available.

OID

MIB

Name

Units

Notes

1.3.6.1.2.1.31.1.1.1.6

IF-MIB

In Rate

Kbps

If unavailable, 1.3.6.1.2.1.2.2.1.10 (RFC1213-MIB)
will be used instead

 

 

In Usage

Percent

Calculated by dividing In Rate by interface speed.

1.3.6.1.2.1.31.1.1.1.10

IF-MIB

Out Rate

Kbps

If unavailable, 1.3.6.1.2.1.2.2.1.16 (RFC1213-MIB)
will be used instead

 

 

Out Usage

Percent

Calculated by dividing Out Rate by interface speed.

 

 

Usage

Percent

Calculated by adding In Usage and Out Usage together.

1.3.6.1.2.1.2.2.1.14

RFC1213-MIB

In Errors

#/sec

 

1.3.6.1.2.1.2.2.1.20

RFC1213-MIB

Out Errors

#/sec

 

 

 

Errors

#/sec

Calculated by adding In Errors and Out Errors together.

1.3.6.1.2.1.2.2.1.13

RFC1213-MIB

In Discards

#/sec

 

1.3.6.1.2.1.2.2.1.19

RFC1213-MIB

Out Discards

#/sec

 


 

 

Discards

#/sec

Calculated by adding In Discards and Out Discards together.

Troubleshooting with snmpwalk

Although most SNMP enabled network devices provide the OID's listed above, not all do. If there are issues adding a network device to Uptime Infrastructure Monitor, it is helpful to use snmpwalk to review the OIDs available on the device. The article "Troubleshooting Network Device Issues with snmpwalk" explains how to do this.