You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Current »

The 'Generic SNMP' Plugin Monitor allows monitoring/testing of OID values against any elements within Uptime Infrastructure Monitor (not just netSNMP or Network Devices).

The following fields in the plug-in handle the details around the SNMP version, and appropriate credentials for the different SNMP versions. The correct choices for these fields can typically be found in the device's web admin panel or the vendor's documentation.
SNMP Version

SNMP Port

Community String(v1/v2)

Agent Username (v3)

Authentication Type (v3)

Authentication Passphrase (v3)

Privacy Type (v3)

Privacy Passphrase (v3)

After supplying the SNMP version/credentials, we need to decide what 'SNMP action' the Monitor will attempt to make against the Element. This choice depends on whether we are trying to GET a single value or OID on the device (ie. SysDescr ), or looking to WALK an entire column in an SNMP Table Array ( ifSpeed column in the ifTable) and retrieve all the values. See the below Get/Walk sections for further explanation of what choice to make here, and examples for how to setup the plug-in.

The 'SNMP Data Type' field depends on what syntax or value that the OID is expected to return, and is used by the plug-in to handle whether we perform String or Integer type comparisons against the SNMP output. 

Get

Using the 'Generic SNMP' Plug-in Monitor for a 'snmp get' action will allow you to pull a single OID value into Uptime Infrastructure Monitor. Unlike the 'SNMP Poller' Monitor, this OID value does not have to be explicitly defined within a MIB file. This allows you to monitor for 'Dynamic OIDs' that typically represent a single interface or drive on a device that isn't fully defined within the associated MIB files.

SNMP Action: GET

SNMP Data Type: String or Integer, set this based on what your OID is excepted to return.

SNMP OID: The OID you are looking to monitor

Here's an example of how to get the SysDescr OID and return that value to Uptime Infrastructure Monitor as a string.

SNMP Action: GET

SNMP Data Type: String

SNMP OID: .1.3.6.1.2.1.1.1.0 

Walk

The 'SNMP Walk' action allows you to pull an entire column from an SNMP array Table, and perform a threshold comparison on each result in that column.

SNMP Action: Walk

SNMP Data Type: String or Integer, set this based on what your OID is excepted to return.

SNMP OID: The OID for the column you need to do the threshold comparison against

SNMP Table Index OID (Walk): The OID for a column within the same Table array that can act as an index or name for the results returned.

SNMP Table Index Filter: This field allows you to apply an optional regex filter against the SNMP Table Index, and only returns the results that match. Leave blank if you don't want to filter based on the 'SNMP Table Index OID'

Here's an example of how to walk the ifInErrors column of the ifTable and return the results matched to their ifDescr: 

SNMP Action: Walk

SNMP Data Type: Integer

SNMP OID: .1.3.6.1.2.1.2.2.1.14

SNMP Table Index OID (Walk): .1.3.6.1.2.1.2.2.1.2
Here's an example of how to check the ifOperStatus column in the same ifTable but only return results for those that have a ifDescr of 'vlan': 

SNMP Action: Walk

SNMP Data Type: String

SNMP OID: .1.3.6.1.2.1.2.2.1.8

SNMP Table Index OID (Walk): .1.3.6.1.2.1.2.2.1.2

SNMP Table Index Filter: vlan

  • No labels