| Note: Built-In Function Rules Usage Options |
Stores the RDML code associated with a function from a working list.
This Built-In Function can only be used against a function that has been previously placed into an edit session using the START_FUNCTION_EDIT Built-In Function.
Special Note: This Built-In Function provides access to very advanced facilities that basically allow RDML functions to construct new RDML functions. This is a very specialized area that requires very good knowledge of the LANSA product. Use of this Built-In Function in a "commercial" application (e.g. Order Entry) is not normal and should not be attempted. |
This is a Specialized Built-In Function for use in a Development Environment only.
No | Type | Req/ Opt | Description | Min Len | Max Len | Min Dec | Max Dec |
|---|---|---|---|---|---|---|---|
1 | L | Req | Working list Name If the edit session is Include RDML audit stamps N, then the working list must have an aggregate entry length of 72 bytes where each entry is composed of: From - To Description 1 - 4 Command sequence number Signed(4, 0) 5 - 7 Command Label A(3) 8 - 17 Command A(10). 19 - 72 Command Parameters A(55). If the edit session is Include RDML audit stamps Y, then the working list must have an aggregate entry length of 99 bytes, where, in addition to the positions described for Include RDML audit stamps N, each entry is composed of: From - To Description 73 - 73 Command Changed Flag, to be set to Y if the RDML command was added or changed in this edit session, N otherwise.A(1) 74 - 81 Command Changed Date S(8, 0). (CCYYMMDD). Must never be changed or set. 82 - 91 Command Changed User. Must never be changed or set. A(10). 92 - 99 Command Changed Task. Must never be changed or set. A(8). | ||||
2 | A | Req | Nominated Editing Source Must not be blank or LAN. Used to "tag" edited RDML with last editor identifier. *S=Signed | 3 | 3 |
No | Type | Req/ Opt | Description | Min Len | Max Len | Min Dec | Max Dec |
|---|---|---|---|---|---|---|---|
1 | A | Req | Return code OK = operation completed ER = fatal error detected | 2 | 2 |
If the function is being created by this edit session and the edit session is Include RDML audit stamps Y, the value of the Command Changed Flag is ignored.
Commands that have more than 55 bytes of parameters must be formatted across multiple entries as shown in this example:
Seq Lab Command Parameters
0001 ********** This is a comment line
0002 SET_MODE TO(*CHANGE)
0003 L32 GROUP_BY NAME(#GROUP) FIELDS(#FIELD001 #FIELD002
0003 #FIELD003 #FIELD004 #FIELD005 #FIELD006)
0004 DISPLAY FIELDS(#GROUP)
0005 MENU
0006 ********** This is a comment line