This section includes the following topic:

Updating the Oracle version

When you upgrade your Oracle version, You must uninstall the monitored instance(s) from Precise, and then reinstall the monitored instance(s) using the same instance ID.

  1. Make sure the Warehouse Maintenance (Weekly) does not run soon.
  2. To uninstall:
    1. Navigate to the AdminPoint installation.
    2. Select Instances and Clusters.
    3. Select the instance(s) to be uninstalled, and then click Delete.
  3. To reinstall:
    1. Navigate to the AdminPoint installation.
    2. Select Instances and Clusters.
    3. Click Add Instance.
    4. Complete the appropriate fields, and then click Advanced.
    5. Click the option to install using the same instance ID (Associate the instance with the data of the deleted instance).

If the Warehouse Maintenance (Weekly) Warehouse Process is scheduled to run in between uninstalling/ reinstalling, in Parameters, make sure the box to Purge data of deleted instance is not checked.