Updating from v9.0.1 to v9.6.1 using the CLI utility
This section includes the following topic:
Applying the v9.0.1 to v9.6.1 update using the CLI utility
NOTE | Before starting the update using the CLI utility, you must download the latest infra hotfix for version 9.0.1 and install it on the Precise FocalPoint. Verify that you completed all action items before starting the update. |
To apply the upgrade update
- Run the CLI i3-update-load command to load the upgrade.zip file:
Windows infra\bin\psin_cli.bat
-action i3-update-load
-i3-user admin
-i3-clear-password admin
-zip-file Pr ecise DVD\Upg rade to v9.6.0\U pgrade.zip
UNIX ./infra/bin/psin_cli.sh
-action i3-update-load
-i3-user admin
-i3-clear-password admin
-zip-file Pr ecise DVD\Upg rade to v9.6.0\U pgrade.zip - Run the CLI i3-update-prepare command to prepare the update:
Windows infra\bin\psin_cli.bat
-action i3-update-prepare
-i3-user admin
-i3-clear-password admin
-{-servers “<ser ver s>” | -all-servers true}
-updates-ids V960_UPGRADE
UNIX ./infra/bin/psin_cli.sh
-action i3-update-prepare
-i3-user admin
-i3-clear-password admin
-{-servers “<ser ver s>” | -all-servers true}
-updates-ids V960_UPGRADE - Run the CLI i3-update-install command to apply the update:
Windows infra\bin\psin_cli.bat
-action i3-update-install
-i3-user admin
-i3-clear-password admin
{-servers "<servers>" | -all-servers true}
-updates-ids V960_UPGRADE
UNIX ./infra/bin/psin_cli.sh
-action i3-update-install
-i3-user admin
-i3-clear-password admin
{-servers "<servers>" | -all-servers true}
-updates-ids V960_UPGRADE - Perform the post-update action items that appear.