Installation with Precise CLI

This section includes the following topics:

•    Installing the Precise Framework

•    Installing Precise FocalPoints

•    Installing Servers

•    Installing secured servers with the Precise CLI utility

•    Updating services Authentication using the Precise CLI Utility

•    Installing a Tier with the Precise CLI utility

•    Extricate command

•    Edit & uninstall

•    Installing a new instance while keeping historical data from an old instance

Installing the Precise Framework

The Precise Framework can be installed directly from the Precise v9.6 download onto the Precise FocalPoint server. You can use the Precise CLI utility to install the following Framework components:

•    Precise FocalPoint

•    PMDB FocalPoint

•    Alerts FocalPoint

•    Report Manager FocalPoint

•    Insight FocalPoint

•    TPM FocalPoint

For information on manually installing the PMDB schemas, see the Precise Installation Guide.

How to install the Precise Framework

Install the Precise Framework by performing the following steps:

1.    Prepare XML parameters file to specify the Framework installation parameters and log in to the server on which you have planned to install the Precise FocalPoint.

2.    On this server, run the following command from the  <precise_root> folder to install the CLI utility installation script:

Windows    <installation_DVD>

\CLI\psin_framework_install.bat

<full_path_to_XML_parameters_file>

UNIX    <installation_DVD>

/CLI/psin_framework_install.sh

<full_path_to_XML_parameters_file>

After running the script, you may be required to perform manual post-installation tasks to complete the installation.

 

3.    If an error occurs, fix the problem and rerun the installation scripts. (In the case of an error, there is no need to delete the installation files.) If a critical error occurs before the Precise FocalPoint is installed, an error message is displayed. At the end of CLI utility installation, a message appears "Installation complete - check logs for details". The relevant logs for installation are as follows:

o    <precise_root>/logs/psin_framework_install.out

o    <precise_root>/logs/infra.CLI.log

If installation is successful, a message appears "Framework install setup process done".

NOTE    For Windows Server which has the User Account Control enabled, you must run this command using Administrator permissions: Click Start Menu, right-click Command Prompt, click "Run as administrator", click Continue button, to approve the operation. Run the command specified above.

About the Precise Framework parameter file

You need to prepare the Framework parameter file by creating an XML file with tags that represent the installation parameters and inserting the appropriate values.

The following is an example of a server parameters file:

<parameters>

<parameter name="setup-process" value="framework"/>

<parameter name="setup-mode" value="install"/>

<parameter name="installation-cd-path" value="d:\"/>

<parameter name="i3fp-server-machine-name" value="server1"/>

<parameter name="dbms-type" value="mssql"/>

<parameter name="dbms-instance" value="DATABASE1"/>

<parameter name="dbms-database" value="PWV8"/>

<parameter name="dbms-dba-user" value="pwv8"/>

<parameter name="dbms-dba-clear-password" value="mypass"/>

<parameter name="gui-port" value="20820"/>

<parameter name="gui-shutdown-port" value="20821"/>

<parameter name="server-machine-installation-folder-server1" value="d:\precise"/>

<parameter name="server-machine-port-server1" value="20802"/>

</parameters>

The parameters file is an XML file containing a list of parameters for a Precise framework installation.

Table 2-1    Elements of the Precise framework parameter file

Element    Description

server-machine-installation-folder-server-name    Indicates the folder in which Precise installation files are stored.

Values: String

Mandatory for Precise FocalPoint Server: Yes

Mandatory for other servers: Yes, unless you prefer to perform a manual installation.

server-machine-port-server-name    Port of the Precise Listener on the local server.

Values: Numeric 1025–65535

Mandatory: Yes

setup-process    Marked always as framework.

Mandatory: Yes

setup-mode    Must be in one of the following modes:

■    install (used to install Precise Framework)

■    edit (used to update Precise Framework)

■    uninstall (used to uninstall Precise Framework)

Mandatory: Yes

installation-cd-path    Indicates the absolute path to the folder where the Precise v9.6 download was downloaded to.

Values: String

Mandatory: Yes

i3fp-server-machine-name    Name of the Precise FocalPoint server. The name must be written in lowercase letters only. Can be a fully qualified name or IP address.

Values: String

Mandatory: Yes

gui-port    Port of the Graphics User Interface (GUI) server.

Values: Numeric 1025–65535 (must not be identical to other ports specified)

Mandatory: Yes

gui-shutdown-port    Local port for controlling the GUI.

Values: Numeric 1025 -65535 (must not be identical to other ports specified)

Mandatory: Yes

server-machine-service-unique-id-server-name    A unique name used in the installation of all Precise agents. This is used if you want to support more than one Precise installation system on the server (for example, in cluster applications).

Relevant only for Windows servers.

Values: Alphanumeric

Mandatory: No

pw-server-machine-name    Name of the PMDB FocalPoint server. The name must be written in lowercase letters only.

Values: String

Mandatory: No, defaults to the Precise FocalPoint.

alerts-server-machine-name    Name of the Alerts FocalPoint server. The name must be written in lowercase letters only.

Values: String

Mandatory: No, defaults to the Precise PMDB FocalPoint.

foresight-server-machine-name    Name of the Report Manager FocalPoint server. The name must be written in lowercase letters only.

 

Values: String

Mandatory: No, defaults to the Precise PMDB FocalPoint.

insight-server-machine-name    Name of the Insight FocalPoint server. The name must be written in lowercase letters only.

Values: String

Mandatory: No, defaults to the Precise PMDB FocalPoint.

 

NOTE    The Framework CLI supports installing the framework FocalPoint on different servers. If the servers are UNIX servers, the framework's servers will be automatically installed by the framework CLI (you need to supply user and password parameters for each UNIX server). If the servers are Windows servers and different servers are required for the framework FocalPoints, perform the steps described in the following procedure.

To install the framework FocalPoint on different Windows servers

1.    Only install the Precise FocalPoint using the framework CLI command.

2.    Install the other FocalPoints with the Add Server CLI command. See Installing Servers on page 20.

3.    Install all required framework FocalPoints with the framework CLI command.

 

Installing the PMDB FocalPoint using an Oracle database

Additional parameters are needed for installing the PMDB FocalPoint on an Oracle database.

The following table lists the additional parameters needed for a PMDB installation using an Oracle database.

Table 2-2    Additional parameter file elements for the PMDB on an Oracle database

Element    Description

dbms-type    Marked always as oracle.

Values: String

Mandatory: Yes

dbms-server    Name of the Oracle database server.

Values: String

Mandatory: Yes

dbms-instance    Oracle instance name (SID).

Values: String

Mandatory: Yes

dbms-port    Oracle instance Listener port.

Values: Integer

Mandatory: Yes

dbms-dba-user    User name for the Oracle user with DBA privileges. Will only be used during installation.

Values: String

Mandatory: Yes, if manual-schema is set to false.

dbms-tablespace-large-name    Name of the large tablespace that will be used by PMDB.

Values: String

Mandatory: No

Default value: PRECISE_PW_TAB_LARGE

dbms-tablespace-medium-name    Name of the medium tablespace that will be used by PMDB.

Values: String

Mandatory: No

Default value: PRECISE_PW_TAB_MEDIUM

dbms-tablespace-small-name    Name of the small tablespace that will be used by PMDB.

Values: String

Mandatory: No

Default value: PRECISE_PW_TAB_SMALL

dbms-tablespace-infral-name    Name of the infra tablespace that will be used by PMDB.

Values: String

Mandatory: No

Default value: PRECISE_PW_TAB_INFRA

dbms-tablespace-sts-name    Name of the sts tablespace that will be used by PMDB.

Values: String

Mandatory: No

Default value: PRECISE_PW_TAB_STS

dbms-tablespace-large-initial-size    Initial size for the large tablespace.

Values: Integer

Mandatory: No

Default value: 64

dbms-tablespace-medium-initial-size    Initial size for the medium tablespace.

Values: Integer

Mandatory: No

Default value: 64

dbms-tablespace-small-initial-size    Initial size for the small tablespace.

Values: Integer

Mandatory: No

Default value: 64

dbms-tablespace-infra-initial-size    Initial size for the infra tablespace.

Values: Integer

Mandatory: No

Default value: 64

dbms-tablespace-sts-initial-size    Initial size for the STS tablespace.

Values: Integer

Mandatory: No

Default value 32

dbms-tablespace-large-uniform-size    Uniform size for the large tablespace.

Values: Integer

Mandatory: No

Default value: 2048

dbms-tablespace-medium-uniform-size    Uniform size for the medium tablespace.

Values: Integer

Mandatory: No

Default value: 512

dbms-tablespace-small-uniform-size    Uniform size for the small tablespace.

Values: Integer

Mandatory: No

Default value: 80

dbms-tablespace-infra-uniform-size    Uniform size for the infra tablespace.

Values: Integer

Mandatory: No

Default value: 80

dbms-tablespace-sts-uniform-size    Uniform size for the STS tablespace.

Values: Integer

Mandatory: No

Default value: 256

dbms-tablespace-large-extent-size    Extent size for the large tablespace

Value: Integer Mandatory: No

Default value: 512

dbms-tablespace-medium-extent-size    Extent size for the medium tablespace

Value: Integer Mandatory: No

Default value: 512

dbms-tablespace-small-extent-size    Extent size for the small tablespace

Value: Integer Mandatory: No

Default value: 512

dbms-tablespace-infra-extent-size    Extent size for the infra tablespace

Value: Integer Mandatory: No

Default value: 512

dbms-tablespace-sts-extent-size    Extent size for the sts tablespace

Value: Integer Mandatory: No

Default value: 1024

dbms-ind-large-name    Name of the large index tablespace that will be used by PMDB.

Values: String

Mandatory: No

Default value: PRECISE_PW_IND_LARGE

dbms-ind-medium-name    Name of the medium index tablespace that will be used by PMDB.

Values: String

Mandatory: No

Default value: PRECISE_PW_IND_MEDIUM

dbms-ind-small-name    Name of the small index tablespace that will be used by PMDB.

Values: String

Mandatory: No

Default value: PRECISE_PW_IND_SMALL

dbms-ind-large-initial-size    Initial size for the large index tablespace.

Values: Integer

Mandatory: No

Default value: 64

dbms-ind-medium-initial-size    Initial size for the medium index tablespace.

Values: Integer

Mandatory: No

Default value: 64

dbms-ind-small-initial-size    Initial size for the small index tablespace.

Values: Integer

Mandatory: No

Default value: 64

dbms-ind-large-uniform-size    Uniform size for the large index tablespace.

Values: Integer

Mandatory: No

Default value: 1024

dbms-ind-medium-uniform-size    Uniform size for the medium index tablespace.

Values: Integer

Mandatory: No

Default value: 256

dbms-ind-small-uniform-size    Uniform size for the small index tablespace.

Values: Integer

Mandatory: No

Default value: 80

dbms-ind-large-extent-size    Extent size for the large index tablespace

Value: Integer

Mandatory: No

Default value: 512

dbms-ind-medium-extent-size    Extent size for the medium tablespace

Value: Integer Mandatory: No

Default value: 512

dbms-ind-small-extent-size    Extent size for the small tablespace

Value: Integer Mandatory: No

Default value: 512

manual-schema    Indicates if the schema should be manually installed.

Values: true, false

Mandatory: No.

Default value: false

is-partitioned    Indicates if the database contains partitioning.

Values: true, false

Mandatory: Yes, if manual-schema is true

dbms-version    Database version. Values: 9i, 10g, 11g

Mandatory: Yes, if manual-schema is true

dbms-dba-encrypted-password    Password for the Oracle user with DBA privileges. Will only be used during installation.

Values: Encrypted String

Mandatory: Yes, if manual-schema is set to false.

Alternatively the dbms-dba-clear-password can be used, allowing you to specify a clear password instead of an encrypted string. For more information, see Encrypt command on page 148.

 

dbms-i3-user    User name for the Precise user who owns the PMDB schema.

Values: String

Mandatory: Yes

dbms-i3-encrypted-password    Password for the Precise user with PMDB privileges.

 

Values: Encrypted String

Mandatory: Yes

Alternatively the dbms-i3-clear-password can be used, allowing you to specify a clear password instead of an encrypted string. For more information, see Encrypt command on page 148.

 

dbms-tablespace-temp-name    Storage parameter name for the Precise for Oracle schema. Indicates Temporary tablespace name.

Values: String

Mandatory: No

Default value: PRECISE_PMBD_TMP

dbms-tablespace-temp-file    Storage parameter for the Precise for Oracle schema. Indicates Temporary tablespace file.

Values: String

Mandatory: No

Default value: PRECISE_PMBD_TMP

dbms-tablespaces-folder    Storage parameter for the Precise for Oracle schema. Indicates the folder in which Tablespace datafiles are stored.

Values: String

Mandatory: Yes

dbms-use-bigfile-for-tablespaces    Specify whether the tablespaces will be created as bigfiles.

Values: true, false

Mandatory: No

Default value: true

dbms-service    Specify the name of oracle service in case you want to use oracle cluster

Value: String

Mandatory: No

Installing the PMDB FocalPoint using an MS-SQL Server database

Additional parameters are needed for installing the PMDB FocalPoint on an MS-SQL Server database.

The following table lists the additional parameters needed for a PMDB installation using an MS-SQL Server database.

Table 2-3    Additional parameter file elements for the PMDB on an MS-SQL Server database

Element    Description

manual-schema    Indicates if the schema should be manually installed.

Values: true, false

Mandatory: No.

Default value: false

is-partitioned    Indicates if the database contains partitioning.

Values: true, false

Mandatory: Yes, if manual-schema is true

dbms-version    Database version.

Values: 2005, 2008

Mandatory: Yes, if manual-schema is true

dbms-type    Marked always as SQL Server (mssql).

Mandatory: Yes

dbms-instance    MS-SQL Server instance name. (Must always be uppercase).

Values: String

Mandatory: Yes

dbms-use-win-authentication    Indicates whether the PMBD will be connected using OS authentication.

Values: Boolean

Mandatory: No

Default value: false

NOTE: All focals must be on the Windows server and the service must be configured to run with the user that has privileges on the PMDB.

When using windows authentication, the CLI must be run by a user with permissions to connect to the SQL Server database.

dbms-database    Name of the MS-SQL Server database.

Values: String

Mandatory: Yes

dbms-dba-user    User name for the MS-SQL Server user with DBA privileges to install the schema.

Values: String

Mandatory: Not mandatory if dbms-use-win-authentication is true.

dbms-dba-encrypted-password    Password for the MS-SQL Server user with DBA privileges.

Values: Encrypted String

Mandatory: Not mandatory if dbms-use-win-authentication is true.

Editable: No

Alternatively the dbms-dba-clear-password can be used, allowing you to specify a clear password instead of an encrypted string. For more information, see Encrypt command on page 148.

 

dbms-file-groups    All tables will be created under this file group.

Values: String

Mandatory: No

dbms-collation    New database will be created using this collation.

Values: String

Mandatory: No

Default value: SQL_Latin1_General_CP1_CS_AS

dbms-data-growth    New database data file auto growth size in MB.

Values: Integer

Mandatory: No

Default value: 512

dbms-data-size    New database data file size in MB.

Values: Integer

Mandatory: No

Default value: 1024

dbms-data-path    Folder under the database server where the data file will be created.

Values: String

Mandatory: Yes, if the dbms-database parameter value is a database which does not exist.

dbms-log-path    Folder under the database server where the database log file will be created.

Values: String

Mandatory: Yes, if the dbms-database parameter value is a database which does not exist

dbms-log-size    New database log file size in MB.

Values: Integer

Mandatory: No

Default value: 512

dbms-log-growth    New database log file auto growth size in percent.

Values: Integer

Mandatory: No

Default value: 10

Installing additional parameters to servers where FocalPoints are installed

The following table lists the additional parameters needed for server installation, wherever FocalPoints are installed. These are required only if when installing the Framework FocalPoint on servers other than the Precise FocalPoint. In such cases specify the parameters below for each server and replace server-name (italic) with the real server name.

Table 2-4    Additional parameter file elements for server installation

Element    Description

server-machine-port-server-name    Port of the Precise Listener on the server.

Values: Numeric 1025 -65535

Mandatory: Yes

server-machine-installation-folder-serv er-name    Indicates the folder in which Precise installation files are stored.

Values: String

Mandatory: Yes, unless you prefer to perform a manual server installation.

server-machine-use-communication-re lay-server-name    Indicates whether this server should use relay communication. Select this option if the server resides behind a firewall.

Values: (true/false)

Mandatory for other servers: No

server-machine-flavor-server-name    Type of server. Must be in one of the following servers:

Windows, Unix

Mandatory: Yes, unless you prefer to perform a manual server installation.

server-machine-install-user-server-na me    User name required to install the Precise Listener on the server. Will only be used during installation.

Values: String

Mandatory for other servers: Yes, unless you prefer to perform a manual server installation.

server-machine-install-encrypted-pass word-server-name    Password for the user, required for using Precise Listener services on the server.

Values: Encrypted String

Mandatory: Yes, unless you prefer to perform a manual server installation.

Alternatively the server-machine-install-clear-password-server-name can be used, allowing you to specify a clear password instead of an encrypted string. For more information, see Encrypt command on page 148.

 

server-machine-service-authentication- mode-server-name    Server authentication mode. Precise services are using LocalSystem account. to specify other user account specify "user", and use:

server-machine-service-authentication-user-server-name and

server-machine-service-authentication-encrypted-password-server-name to specify the authentication details:

Values: String

Mandatory: No

server-machine-service-authentication- user-server-name    User account name for Precise services on the server.

Mandatory: Only if server-machine-service-authentication-mode-server-name is set to "user".

Values: String

server-machine-service-authentication- encrypted-password-server-name    Password for the user specified in server-machine-service-authentication-user-server-name.

Values: Encrypted String

Mandatory: Only if server-machine-service-authentication-mode-server-name is set to "user".

Alternatively the server-machine-service-authentication-clear-password-server-name can be used, allowing you to specify a clear password instead of an encrypted string. For more information, see Encrypt command on page 148.

 

server-machine-service-authentication- domain-server-name    Domain of user specified in server-machine-service-authentication-user-server-name

Values: String

Mandatory: Only if server-machine-service-authentication-mode-server-name is set to "user".

server-machine-bind-listener-address-server-name    Indicates whether the Precise Listener on this server should bind the specified server name or all the addresses on the given port.

Values: true/false

Mandatory: No

Installing Precise FocalPoints

Installing a Precise FocalPoint on a server

When using the CLI for installation, you must explicitly install the FocalPoint. This is unlike the GUI-based installation, in which FocalPoints are automatically installed with the first instance relevant. To install a Precise FocalPoint, the you should create an installation parameters file and run the Precise CLI utility installation script on the main Precise FocalPoint.

To install a Precise FocalPoint on a server

1.    Build a parameter XML file to be used as input for the installation scripts.

2.    Run the following command from the <precise_root> folder on the main Precise FocalPoint.

Windows    infra\bin\psin_cli.bat

-i3-user <user_name>

{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}

-action setup

-parametersfile <path_to_parameters_file>

UNIX    ./infra/bin/psin_cli.sh

-i3-user <user_name>

{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}

-action setup

-parametersfile <path_to_parameters_file>

 

About the Precise FocalPoint parameter file

You need to prepare the Precise FocalPoint parameter file by creating an XML file with tags that represent the installation parameters and inserting the appropriate values.

The following is an example of a Precise FocalPoint parameters file that installs the Oracle FocalPoint on server1:

<parameters>

<parameter name="setup-process" value="focal-OR"/>

<parameter name="setup-mode" value="install"/>

<parameter name="focal-server-machine-name" value="server1"/>

<parameter name="installation-cd-path" value="\\filesvr\Precise i3\ installation"/>

</parameters>

The following table lists the needed parameters for a Precise FocalPoint installation. The parameter format is:

<parameters>

<parameter name="..." value="..."/> ...

</parameters>

Table 2-5    Parameter file elements for a Precise FocalPoint installation

Element    Description

setup-process    Indicates the name of the setup process

Values: String; focal-<PRODUCT CODE>, for example: focal-JE, focal-OR. For more information, see Product Codes on page 175.

Mandatory: Yes

Editable: No

setup-mode    Must be in one of the following modes:

■    install (to install)

■    edit (to update)

■    uninstall (to uninstall)

Mandatory: Yes

 

Editable: Yes

focal-server-machine-name    Name of the server where the Precise FocalPoint will be installed. The name must be written in lowercase letters only. Can be a fully qualified name or IP address.

Values: String

Mandatory: Yes

Editable: No

installation-cd-path    Indicates the absolute path to the folder where the Precise v9.6 download was downloaded to.

Values: String

Mandatory: Yes

Editable: Yes

Installing Servers

The first stage in a server installation using the CLI utility requires installing and registering the server in Precise. The server is registered in the Precise database, a Precise Listener is started on the server, and communication between the Precise FocalPoint and the Precise Listener is enabled.

NOTE    To promote efficiency, servers can also be installed automatically. For more information, see Auto Deployment on page 108.

 

Before installing a server using the CLI utility, verify the following issues:

•    The Precise communication port is open in both directions (between the Precise FocalPoint server and the target server).

•    CLI can handle installation packages. For more information, see Installation packages on page 8. To install the servers with the CLI utility

 

1.    Run the following command on the main Precise FocalPoint server:

Windows    infra\bin\psin_cli.bat

-i3-user <user_name>

{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}

-action list-required-files-for-new-server

-bits <new server bits (32/64)>

-os <os _type>

UNIX    ./infra/bin/psin_cli.sh

-i3-user <user_name>

{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}

-action list-required-files-for-new-server

-bits <new server bits (32/64)>

-os <os_type>

The CLI creates an XML file containing the list of required installation packages for the server.

Table 2-6    Server Installation

Element    Description

i3-user    See Authenticate to CLI Utility on page 8.

 

i3-encrypted-password    See Authenticate to CLI Utility on page 8.

 

action    Always list-required-files-for-new-server

Mandatory: Yes

bits    The OS bits in the new added server

Values: 32 or 64

Mandatory: Yes

os    The added server OS

Values: See Operating System Type and Flavor on page 176.

Mandatory: Yes

2.    On the new server create the installation folder and create new sub folder under it: distribution.

3.    Copy the files specified the XML file created in Step 1 to the new server in the

<precise_root>/distribution

4.    Login to the server using the Precise user

5.    CD <precise_root>

Run the following command:

Windows    distribution\psin_ba_WIN.exe -s

UNIX    ./distribution/psin_ba_<os_type> -s

For more information, see Operating System Type and Flavor on page 176.

Note the -s argument

6.    For each of the other files you've copied, run the following command:

Windows    infra\bin\psin_file_new.exe -manual -extract distribution\<the_file_name> -event install

UNIX    ./infra/bin/psin_file_new -manual -extract distribution/<the_file_name> -event install

7.    Create an XML file containing the relevant installation parameters. Place the file in <precise_root> folder on the target server. You can also set up this file in advance.

By default, installing an non-secured local server using the CLI is not enabled. To enable a non-secured CLI server installation, set the Precise registry parameter:

registry\products\infrastructure\setup\settings\enable-local-server-cli to true, and restart Precise FocalPoint.

 

8.    Run the following command to execute the CLI utility installation script from the <precise_root> folder on the target server:

Windows    infra\bin\psin_cli.bat

-i3-user <user_name>

{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}

-action setup-server -parametersfile <server_installation_parameters_file_name>

UNIX    ./infra/bin/psin_cli.sh

-i3-user <user_name>

{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}

-action setup-server

-parametersfile <server_installation_parameters_file_name>

 

NOTE    For Windows Server 2008 (Windows Longhorn) you must run this command using Administrator permissions: Click Start Menu, right-click Command Prompt, click Run as administrator, click Continue, to approve the operation. Run the command specified above.

Table 2-7    CLI utility installation script

Element    Description

i3-user    See Authenticate to CLI Utility on page 8.

 

i3-encrypted-password    See Authenticate to CLI Utility on page 8.

 

action    always setup-server

Mandatory: Yes

parametersfile    path to parameters file

Mandatory: Yes

About the server parameter file

You need to prepare the Server parameter file by creating an XML file with tags that represent the installation parameters and inserting the appropriate values.

The following is an example of a server parameter file:

<parameters>

<parameter name="setup-mode" value="install"/>

<parameter name="setup-process" value="server" />

<parameter name="installation-cd-path" value="d:\" />

<parameter name="handle-server-machine-name" value="poolserver5" />

<parameter name="server-machine-port-poolserver5" value="3002" />

<parameter name="server-machine-flavor-poolserver5" value="Windows" />

<parameter name="i3fp-server-machine-name" value="focalmachine" />

<parameter name="focalmachine-server-machine-port" value="20702" />

</parameters>

The following table describes the elements of the parameter file.

Table 2-8    Elements of the servers parameter file for product Collectors

Element    Description

setup-mode    Setup mode that is used.

Values: install, edit, uninstall

Mandatory: Yes

setup-process    Setup process.

Value: always server.

Mandatory: Yes

handle-server-machine-name    Name of the local server. Can be a fully qualified name or IP address.

The server name must be recognized by the Precise FocalPoint server, for example, it should be registered in DNS.

Values: String

Mandatory: Yes

server-machine-port-server-name    Port of the Precise Listener on the local server.

Values: Numeric 1025–65535

Mandatory: Yes

i3fp-server-machine-name    Name of the Precise FocalPoint server. Can be fully qualified name or IP address.

The Precise FocalPoint server name must be recognized by the newly added server, for example, it should be registered in DNS.

Values: String

Mandatory: Yes

server-machine-port-i3fp-server-name    Port of the Precise FocalPoint Listener. Replace i3fp-server-name with the name of Precise FocalPoint as shown in Precise GUI.

Values: Numeric 1025–65535

Mandatory: Yes

server-machine-use-communication-relay

-server-name    The Communication Relay provides a solution to a firewall restrictions problem. For more details see the Precise Installation Guide.

Value: (true/false)

Mandatory: No.

environment-name    Related application name

Values: String

Mandatory: Yes, in case of federation installation.

server-machine-service-authentication-us er-server-name    User account name for Precise services on the server.

Values: String

Mandatory: Only if server-machine-service-authentication-mode-server-name is set to "user".

server-machine-service-authentication-en crypted-password-server-name    Password for the user specified in server-machine-service-authentication-user-server-name.

Values: Encrypted String

Mandatory: Only if server-machine-service-authentication-mode-server-name is set to "user".

Alternatively the server-machine-service-authentication-clear-password-server-name can be used, allowing you to specify a clear password instead of an encrypted string. For more information, see Encrypt command on page 148.

 

server-machine-service-authentication-do main-server-name    Domain of user specified in server-machine-service-authentication-user-server-name

Values: String

Mandatory: Only if server-machine-service-authentication-mode-server-name is set to "user".

server-machine-service-unique-id-server- name    A unique services suffix used in the installation of all Precise agents allows installation of several Precise installations folders on the same server.

Relevant only for Windows servers.

Values: String

Mandatory: No

server-machine-service-authentication-mo de-server-name    Server authentication mode. Precise services are using LocalSystem account. to specify other user account specify "user", and use:

server-machine-service-authentication-user-server-name and

server-machine-service-authentication-encrypted-password-server-name to specify the authentication details:

Values: user or localsystem

Mandatory: No

server-machine-secured-protocol-server-n ame    The secured installation is using an existing security protocols and methods such as blowfish and SSH to ensure that the communication encryption keys are safely copied to the target server

Value: true, false

Mandatory: No

server-machine-security-clear-password-server-name    Security password.

Value: String

Mandatory: Only on secured remote Manual installation.

server-machine-install-user-server-name    User name required to install the Precise Listener on the server. Will only be used during installation.

Value: String

Mandatory: Only on secured remote automatic installation.

server-machine-install-encrypted-passwor d-server-name    Password for the user, required for using Precise Listener services on the server.

Values: Encrypted String

Mandatory: Yes, unless you prefer to perform a manual server installation.

Alternatively the server-machine-install-clear-password-server-name can be used, allowing you to specify a clear password instead of an encrypted string. For more information, see Encrypt command on page 148.

 

server-machine-installation-folder-server- name    Indicates the folder in which Precise installation files are stored.

Values: String

Mandatory: Yes, unless you prefer to perform a manual server installation.

server-machine-flavor-server-name    Type of server. Must be in one of the following servers:

Windows, UNIX

Values: String

Mandatory: Yes

server-machine-use-jre-server-name    Indicates whether a Java-based Listener will be installed on the server or not.

NOTE: A Java-based Listener is required for ShortTimeSlice support.

Values: true, false.

Default: true for servers whose OS supports JRE 1.6. You should use false if the server’s OS does not support JRE 1.6 or to reduce the memory footprint of the Precise Listener.

Mandatory: No

server-machine-bind-listener-address-ser ver-name    Indicates whether the Precise Listener on this server should bind the specific server name or bind all the addresses on the given port.

Values: true, false

 

Mandatory: No

server-machine-ssl-server-name    Indicates whether this Listener will function as an SSL Listener.

NOTE: An SSL Listener is necessary to communicate with remote monitored instances. Values: true, false

Default: false

Mandatory: No

For more information, see J2EE Remote Instance Monitoring on page 112.

 

server-machine-ssl-port-server-name    Indicates the SSL port this Listener will listen too.

Values: Integer

Default: 443

Mandatory: No

For more information, see J2EE Remote Instance Monitoring on page 112.

 

server-machine-consumer-server-name    Indicates whether this Listener will function as a consumer that will pull data from SSL Listeners.

Values: true, false

Default: false

Mandatory: No

For more information, see J2EE Remote Instance Monitoring on page 112.

 

server-machine-consume-target-server-n ame    Indicates a target server that contains an SSL Listener.

By setting this parameter, the installed server will consume remote data only from the specified target server. If this parameter is not specified and the server-machine-consumer-server-name is set to true, the installed server will consume data from all servers that contain SSL Listeners.

This parameter should only be set if the server-machine-consumer-server-name is set to true and you want to pull data from a specific SSL Listener.

NOTE: The target server specified in this parameter must be defined as an SSL Listener. Values: String (server name)

Mandatory: No

For more information, see J2EE Remote Instance Monitoring on page 112.

 

Installing secured servers with the Precise CLI utility

The server installation CLI described above, assumes it can use non-secured protocols such as telnet, and can transfer the communication encryption key as clear text over the network. If this is a problem, you can install the server using a secure CLI. The secured installation uses existing security protocols and methods such as blowfish and SSH to ensure that the communication encryption keys are safely copied to the target server. It’s possible that the secured server installation might require more manual action items than non-secure server CLI installation. You can use one of the following methods to perform secured server installation:

•    Remote Automatic mode

•    Local mode

 

Remote Automatic mode

This mode may be used only if the target server is a UNIX server that runs SSH (secured shell).

1.    Prepare the server parameters file and save it to the <precise_root> folder on the main Precise FocalPoint.

For more information, see Table 2-8 on page 22. Mandatory parameters for this installation method are:

server-machine-secured-protocol-server-name true server-machine-install-encrypted-password-server-name server-machine-installation-folder-server-name

server-machine-flavor-server-name

server-machine-install-user-server-name

You must not supply:

server-machine-security-clear-password-server-name

2.    On the main Precise FocalPoint, run the following command from <precise_root> folder:

Windows    infra\bin\psin_cli.bat

-i3-user <user_name>

{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}

-action setup

-parametersfile <server_parameters_file_path>

UNIX    ./infra/bin/psin_cli.sh

-i3-user <user_name>

{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}

-action setup

-parametersfile <server_parameters_file_path>

 

NOTE    Precise supports most of the common SSH for UNIX. If you are unable to install using the automatic mode, try the Local mode below.

 

Local mode

Use this mode for Windows server or when your server does not have SSH installed.

1.    Prepare server parameters file. For more information, see Table 2-8 on page 22.

Mandatory parameters for this installation are:

server-machine-secured-protocol-server-name true

2.    On the main Precise FocalPoint server, run the following command from the <precise_root> folder:

Windows    infra\bin\psin_cli.bat

-i3-user <user_name>

{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}

-action secure-crypt-keys

-ba-secure-clear-password <security_password>

UNIX    ./infra/bin/psin_cli.sh

-i3-user <user_name>

{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}

-action secure-crypt-keys

-ba-secure-clear-password <security_password>

The command will generate a key file on the Precise FocalPoint server, under the products/i3fp/security/keys/ folder.

Table 2-9    Local mode

Element    Descriptions

i3-user    See Authenticate to CLI Utility on page 8.

 

i3-encrypted-password    See Authenticate to CLI Utility on page 8.

 

action    always secure-crypt-keys

Mandatory: Yes

ba-secure-encrypted-password    Password used to encrypt the communication key, up to 8 characters.

Mandatory: Yes

Alternatively the -i3-clear-password can be used, allowing you to specify a clear password instead of an encrypted string.

3.    Copy and extract the server packages on the target server as specified in Installing Servers on page 20.

4.    Copy key file from: products/i3fp/security/keys/keys.xml on the main Precise FocalPoint to the target server, to the ./infra folder.

5.    On the target server, run the following command from the <precise_root> folder:

Windows    infra\bin\psin_infra.exe

-manual-extricate-crypt <security_password>

UNIX    ../infra/bin/psin_infra

-manual-extricate-crypt <security_password>

The command will extricate the security keys on the target server.

6.    On the target server, run the following command from the <precise_root> folder. For more information, see Installing Servers on page 20.

Windows    infra\bin\psin_cli.bat

-i3-user <user_name>

{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}

-action setup-server

-parametersfile <server_parameters_file_path>

UNIX    ./infra/bin/psin_cli.sh

-i3-user <user_name>

{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}

-action setup-server

-parametersfile <server_parameters_file_path>

Updating services Authentication using the Precise CLI Utility

To update the user authentication of your Precise Windows services, fill in the following authentication parameters and then run the server setup installation in edit mode.

server-machine-service-authentication-mode-server-name server-machine-service-authentication-domain-server-name server-machine-service-authentication-user-server-name

server-machine-service-authentication-encrypted-password-server-name

For parameter details, see Table 2-10 on page 28.

Installing a Tier with the Precise CLI utility

Once you installed the Precise framework, you can install the Tiers that comprise your Precise suite. Click on the relevant section below, for how to install your Tier using CLI:

•    Installing Precise for Oracle with the Precise CLI utility

•    Installing Precise for Storage with the Precise CLI utility

•    Installing Precise for J2EE with the Precise CLI utility

•    Installing Precise for Web with the Precise CLI utility

•    Installing Precise for Microsoft .NET with the Precise CLI utility

•    Installing Precise for SQL Server with the Precise CLI utility

•    Installing Precise for SAP with the Precise CLI utility

•    Installing Precise for Sybase with the Precise CLI utility

•    Installing Precise for Sybase Replication Server with the Precise CLI utility

•    Installing Precise for DB2 with the Precise CLI utility

•    Installing a Tuxedo instance with the Precise CLI utility

•    Installing a WebSphere MQ instance with the Precise CLI utility

•    Installing an Oracle Applications instance with the Precise CLI utility

•    Installing Other Tier Collectors with the Precise CLI utility

•    Installing an OS instance with the Precise CLI utility

•    Installing an extension for Siebel with the Precise CLI utility

•    Installing Precise for vCenter Server with the Precise CLI utility

Installing Precise for Oracle with the Precise CLI utility

Before installing an Oracle instance with the Precise CLI utility, verify the following issues:

•    The Precise for Oracle FocalPoint was installed.

•    The Precise Listener on the target server on which the Precise for Oracle agent is to be installed was installed.

To install Precise for Oracle with the Precise CLI utility

1.    Create the Precise for Oracle parameter file and save it to the <precise_root> folder on the main Precise FocalPoint. For more information, see About the Precise for Oracle parameter file on page 28.

2.    Run the following command from the <precise_root> folder on the main Precise FocalPoint to execute the Precise CLI installation script.

Windows    infra\bin\psin_cli.bat

-i3-user <user_name>

{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}

-action setup

-parametersfile <precise_for_oracle_installation_parameters_file_name>

 

UNIX    ./infra/bin/psin_cli.sh

-i3-user <user_name>

{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}

-action setup

-parametersfile <precise_for_oracle_installation_parameters_file_name>

About the Precise for Oracle parameter file

You need to prepare the Precise for Oracle parameter file by creating an XML file with elements that represent the installation parameters and inserting the appropriate values.

The following is an example of a Precise for Oracle parameters file:

<parameters>

<parameter name="setup-process" value="apptier-OR"/>

<parameter name="setup-mode" value="install"/>

<parameter name="collector-server-machine-name" value="server5"/>

<parameter name="instance-name" value="ORCL"/>

<parameter name="oracle-home" value="C:\oracle\product\10.1.0\Db_1"/>

<parameter name="oracle-version" value="100"/>

<parameter name="oracle-port" value="1521"/>

<parameter name="oracle-dba-user" value="system"/>

<parameter name="oracle-dba-clear-password" value="dba"/>

<parameter name="oracle-connect-as" value="SYSDBA"/>

<parameter name="oracle-create-new-user" value="true"/>

<parameter name="oracle-i3-user" value="I3_OR_1234"/>

<parameter name="oracle-i3-clear-password" value="mypassword"/>

<parameter name="installation-cd-path" value="d:\"/>

</parameters>

 

The following table describes the updated elements of the parameter file. Element names marked with an asterisk (*) can be updated after installation.

Table 2-10    Elements of the Precise for Oracle parameter file

Element    Description

installation-cd-path    Indicates the absolute path to the folder where the Precise v9.6 download was downloaded to.

Values: String

Mandatory: Yes

setup-process    Setup process. always apptier-OR Mandatory: Yes

setup-mode*    Setup mode.

Values: install, edit, uninstall

Mandatory: Yes

collector-server-machine-name    Name of the server on which the Precise for Oracle Collector will be installed.

Values: String

Mandatory: Yes

environment-name    Name of the application.

Values: String

Mandatory: Yes, for a federation installation

instance-name    Oracle instance name (SID).

Values: String

Mandatory: Yes

oracle-home*    Full path of Oracle home.

Values: String

Mandatory: Yes

oracle-version    Oracle instance version

Values: 81, 90, 100, 110

The values represent the following versions:

81 = Version 8.1

90 = Version 9.0

100 = Version 10

110 = Version 11

Mandatory: Yes

oracle-port*    Oracle instance Listener port.

Values: Numeric

Mandatory: Yes

oracle-dba-user    User name for Oracle user with DBA privileges. Will only be used during installation.

Values: String

Mandatory: Yes

oracle-dba-encrypted-password    Password for Oracle user with DBA privileges. Will only be used during installation.

Values: Encrypted String

Mandatory: Yes

Alternatively the oracle-dba-clear-password can be used, allowing you to specify a clear password instead of an encrypted string.

See Encrypt command on page 148.

 

oracle-connect-as    Connection option for Oracle user with DBA privileges.

When using a manual schema (see the "How to manually install Precise for Oracle database schemas" section in the Precise Installation Guide), this must be specified as Normal.

Values: SYSDBA, Normal

Mandatory: Yes

network-ports    Oracle listener ports.

Specify all the ports you want the Insight Savvy for Network to sample. At least one port must be specified.

Values: port=x||port=y (for example: port=1111||port=2222)

Mandatory: Yes if Install-network is ‘true’.

oracle-create-new-user    Indicates whether the oracle-i3-user is an existing user or the installation should create a new user.

Values: (true/false)

Mandatory: Yes

NOTE: If an Oracle DB schema has been installed manually before the current collector installation, then this parameter should appear explicitly in the parameters file and its value must be "false".

oracle-i3-user    User name of the Oracle user who owns the Precise for Oracle schema.

Values: String

Mandatory: Yes

oracle-i3-encrypted-password    Password of the Oracle user who owns the Precise for Oracle schema.

Values: Encrypted String

See Encrypt command on page 148.

Mandatory: Yes

Alternatively the oracle-i3-clear-password can be used, allowing you to specify a clear password instead of an encrypted string.

oracle-sap-system-name    The SAP system name.

Values: String

Mandatory: Yes, if install-sap-inter-point is true.

oracle-sap-default-application-server    The Application server name used to create the first connection with the SAP system.

Values: String

Mandatory: Yes, if install-sap-inter-point is true.

oracle-sap-system-number    The SAP system number.

Values: String

Mandatory: Yes, if install-sap-inter-point is true.

oracle-sap-user    The SAP system user name.

Values: String

Mandatory: Yes, if install-sap-inter-point is true.

oracle-sap-encrypted-password    The SAP system encrypted password.

Values: Encrypted String

Mandatory: Yes, if install-sap-inter-point is true.

See Encrypt command on page 148.

Alternatively the sap-clear-password can be used, allowing you to specify a clear password instead of an encrypted string.

oracle-sap-client-id    The client ID used to create the first connection with the SAP system.

Values: String

Mandatory: Yes, if install-sap-inter-point is true.

apptier-name    Name of the Tier.

Values: String

Mandatory: No

install-alert-customized    Value: (true/false)

Mandatory: No

Set to true to in case you want to have customized alerts metrics for this instance.

oracle-tablespace-name    Storage parameter for the Precise for Oracle schema. Indicates Tablespace name.

Values: String

Mandatory: No

oracle-tablespace-file    Storage parameter for the Precise for Oracle schema. Indicates Tablespace datafile.

Values: String

Mandatory: No

oracle-tablespace-temp-name    Storage parameter for the Precise for Oracle schema. Indicates Temporary tablespace name.

Values: String

Mandatory: No

oracle-tablespace-temp-file    Storage parameter for the Precise for Oracle schema. Indicates Temporary tablespace file.

Values: String

Mandatory: No

install-psoft-extension*    Installs the PeopleSoft extension

Values: true, false

Mandatory: No

install-sap-inter-point    Indicates whether you want to install a SAP Interpoint.

Values: true, false

Mandatory: No

oracle-history-size*    Oracle session information period (in hours).

Values: 1, 2, 4, 8, 12, 24, 28

Mandatory: No

oracle-collapse-statements*    Collapses statements with different constants in their text into single statements with bind variables.

Values: true, false

Mandatory: No

install-storage-type*    Install Precise for Storage.

Values: empty - for no Precise for Storage ORXP - for HP crosspoint storage

Mandatory: No

oracle-tablespaces-folder    Storage parameter for the Precise for Oracle schema. Indicates the folder in which datafiles are stored.

Values: String

Mandatory: No

install-network*    Associates Oracle activity with network statistics.

Values: true, false

Mandatory: No

oracle-cluster-name    Oracle instance cluster name

Values: string

Mandatory: No

oracle-connection-pool-server    Server name used in the connection pool for the Oracle instance. In case this parameter is not supplied, the collector-server-machine-name is used.

The Precise Oracle FocalPoint creates JDBC connections to the Oracle instance. Use this parameter in case you want the Oracle FocalPoint to connect to the instance using a server name different than the server name specified in collector-server-machine-name parameter.

Value: String

Mandatory: No

Installing Precise for Storage with the Precise CLI utility

Installing Storage Tier Collectors on a server enables you to sample Storage instances on the server. Before installing Storage Tier Collector with the CLI utility, verify the following

•    The Precise for Oracle FocalPoint or Precise for SQL Server FocalPoint is installed.

•    The Precise Listener has been installed on the server where Precise for Storage agent is to be installed.

To install Precise for Storage with the Precise CLI utility

1.    Create the Precise for Storage parameter file and save it to the <precise_root> folder on the main Precise FocalPoint. You can also set up this file in advance. For more information, see About the Precise for Storage parameter file on page 32.

2.    Run the following command from the <precise_root> folder on the main Precise FocalPoint to execute the Precise CLI utility installation script.

Windows    infra\bin\psin_cli.bat

-i3-user <user_name>

{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}

-action setup

-parametersfile <precise_for_storage_installation_parameters_file_name>

UNIX    ./infra/bin/psin_cli.sh

-i3-user <user_name>

{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}

-action setup

-parametersfile <precise_for_storage_installation_parameters_file_name>

About the Precise for Storage parameter file

You need to prepare the Precise for Storage parameter file by creating an XML file with elements that represent the installation parameters and inserting the appropriate values.

The following is an example of a Precise for Storage parameters file:

<parameters>

<parameter name="setup-process" value="apptier-SM"/>

<parameter name="setup-mode" value="install"/>

<parameter name="collector-server-machine-name" value="sun3"/>

<parameter name="storage-type" value="EMC"/>

<parameter name="installation-cd-path" value="d:\"/>

</parameters>

 

The following table describes the updated elements of the parameter file.

Table 2-11    Elements of the Precise for Storage parameter file

Element    Description

installation-cd-path    Indicates the absolute path to the folder where the Precise v9.6 download was downloaded to.

Values: String

Mandatory: Yes

setup-process    Setup process. always apptier-SM Mandatory: Yes

setup-mode    Setup mode

Values: install, edit, uninstall

Mandatory: Yes

collector-server-machine-name    Name of the server on which the Precise for Storage Collector will be installed.

Values: String

Mandatory: Yes

environment-name    Name of the application.

Values: String

Mandatory: Yes, for a federation installation

apptier-name    Name of the Tier.

Values: String

Mandatory: No

emc-database-file    EMC Solution Enabler Database file location.

Values: String

Mandatory: No

emc-gatekeeper-enabled    Enable remote gatekeeper.

Values: true or false

Mandatory: No

emc-gatekeeper-ip    Remote gatekeeper server IP.

Values: String

Mandatory: Yes, if emc-gatekeeper-enabled is true.

emc-gatekeeper-port    Remote gatekeeper server port.

Values: Numeric

Mandatory: Yes, if emc-gatekeeper-enabled is true.

emc-asm-enabled    Enable Oracle ASM support for the EMC Storage agent.

Values: true or false

Mandatory: No

emc-asm-instance    ASM instance name.

Values: String

Mandatory: Yes, if emc-asm-enabled is true.

emc-asm-port    ASM instance port.

Values: String

Mandatory: Yes, if emc-asm-enabled is true.

emc-asm-home    ASM instance home.

Values: String

Mandatory: No

emc-asm-user    User name of an Oracle ASM user with DBA privileges.

Values: String

 

Mandatory: Yes, if emc-asm-enabled is true.

emc-asm-encrypted-password    Password of an Oracle ASM user with DBA privileges.

Values: Encrypted string

Mandatory: Yes, if emc-asm-enabled is true. See Encrypt command on page 148.

Alternatively the emc-clear-password can be used, allowing you to specify a clear password instead of an encrypted string.

Installing Precise for J2EE with the Precise CLI utility

Installing J2EE Tier Collectors on a server enables you to sample a J2EE instance on the server. Before installing a J2EE Tier Collector with the Precise CLI utility, verify the following issues:

•    The Precise Listener has been installed on the server where Precise for J2EE agent is to be installed. To install Precise for J2EE with the Precise CLI utility

1.    Create the Precise for J2EE parameter file and save it to the <precise_root> folder on the main Precise FocalPoint. You can also set up this file in advance. See About the Precise for J2EE parameter file on page 34.

2.    Run the following command from the <precise_root> folder on the main Precise FocalPoint to execute the Precise CLI utility installation script.

Windows    infra\bin\psin_cli.bat

-i3-user <user_name>

{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}

-action setup

-parametersfile <precise_for_j2ee_installation_parameters_file_name>

UNIX    ./infra/bin/psin_cli.sh

-i3-user <user_name>

{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}

-action setup

-parametersfile <precise_for_j2ee_installation_parameters_file_name>

About the Precise for J2EE parameter file

You need to prepare the Precise for J2EE parameter file by creating an XML file with elements that represent the installation parameters and inserting the appropriate values.

The following is an example of a Precise for J2EE parameters file:

<parameters>

<parameter name="setup-process" value="apptier-JE"/>

<parameter name="setup-mode" value="install"/>

<parameter name="instance-identifier" value="J2EE-Application"/>

<parameter name="collector-server-machine-name" value="sun3"/>

<parameter name="j2ee-type" value="JES"/>

<parameter name="j2ee-version" value="3"/>

<parameter name="j2ee-java-home" value="" />

<parameter name="is-cluster" value="false"/>

<parameter name="installation-cd-path" value="d:\"/>

</parameters>

The following table describes the updated elements of the parameter file.

Table 2-12    Elements of the Precise for J2EE parameter file

Element    Description

installation-cd-path    Indicates the absolute path to the folder where the Precise v9.6 download was downloaded to.

Values: String

Mandatory: Yes

setup-process    Setup process. always apptier-JE

Mandatory: Yes

setup-mode    Setup mode

Values: install, edit, uninstall

Mandatory: Yes

collector-server-machine-name    Name of the server on which the Precise for J2EE Collector will be installed.

Values: String

Mandatory: Yes

instance-name    J2EE instance name.

Values: String

Mandatory: No. This parameter is only relevant when the setup-mode is uninstall.

instance-identifier    Used to create the instance name.

Values: String

Mandatory: Yes

is-cluster    Indicates that this instance is part of a cluster.

Values: (true/false).

Mandatory: Yes

show-historical-data    Indicates if historical data from the deleted instance is shown (true) or deleted (false)

Values: true/false

Mandatory: No. This parameter is only relevant when the setup-mode is uninstall.

j2ee-type    J2EE application server type.

Values: WebLogic, WebSphere, JBoss, JEUS, JES, JRun, Tomcat, Resin, Oracle, SAP, Other

Mandatory: Yes

j2ee-version    J2EE application server version.

Values:

For WebLogic: 7.0, 8.1, 8.1 (Portal), 9.0, 9.1, 9.2, 9.2 (Portal), 10.0, 10.0 (Portal), 10.3, 10.3(Portal)

For WebSphere: 5.0, 5.1, 5.1 (Portal), 6.0, 6.1

For JBoss: 3.2, 4.0

For JEUS: 4.2, 5.0

For JES: 2, 3

For JRun: 4.x

For Tomcat: 4.x, 5.0, 5.5

For Resin: 2.1, 3.x

For Oracle 9i AS:

1.0.2.2.2 (Release 1)

9.0.2.x (OC4Jstandalone)

9.0.2.x (Enterprise Edition)

9.0.3.0.0 (OC4J standalone)

9.0.3.0.0 (Enterprise Edition)

9.0.4

11.5.8 (Oracle Applications-Forms Listener Servlet Mode)

10.1.2

10.1.3

For Other: Other

For SAP: 6.4

Mandatory: Yes

j2ee-java-home    J2EE application server java home.

Value: String

Mandatory: Yes (can be empty)

apptier-name    Name of the Tier.

Values: String

Mandatory: No

install-alert-customized    Values: true/false

Mandatory: No

Set to true in case you want to have customized alerts metrics for this instance.

environment-name    Name of the application.

Values: String

Mandatory: Yes, for a federation installation

install-network*    Associates J2EE activity with network statistics.

Values: true, false

Mandatory: No

network-ports    Network ports used by the J2EE instance, specify at least one port.

Values: port=x||port=y (for example: port=1111||port=2222)

Mandatory: Yes if install-network is set to true.

j2ee-weblogic-started-by-node-man ager    Indicates whether this is a managed WebLogic.

Values: true/false

Mandatory: Yes, if j2ee-type is WebLogic.

Installing Precise for Web with the Precise CLI utility

Installing Web Tier Collectors on a server enables you to sample a Web instance on the server. Before installing a Web Tier Collector with the Precise CLI utility, verify the following issues:

•    The Precise for Web FocalPoint is installed and running.

•    The Precise Listener on the target server on which the Precise for Web agent is to be installed, was installed. To install Precise for Web with the Precise CLI utility

1.    Create the Precise for Web parameter file and save it to the <precise_root> folder on the main Precise FocalPoint. You can also set up this file in advance. See About the Precise for Web parameter file (Precise CLI utility) on page 37.

2.    Run the following command from the <precise_root> folder on the main Precise FocalPoint to execute the Precise CLI utility installation script. Use the Precise user that was created when the Precise server was defined.

Windows    infra\bin\psin_cli.bat

-i3-user <user_name>

{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}

-action setup

-parametersfile <precise_for_web_installation_parameters_file_name>

UNIX    ./infra/bin/psin_cli.sh

-i3-user <user_name>

{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}

-action setup

-parametersfile <precise_for_web_installation_parameters_file_name>

About the Precise for Web parameter file (Precise CLI utility)

You need to prepare the Precise for Web parameter file by creating an XML file with elements that represent the installation parameters and inserting the appropriate values.

Example:

<parameters>

<parameter name="setup-process" value="apptier-WW"/>

<parameter name="collector-server-machine-name" value="server1"/>

<parameter name="web-type" value="IIS"/>

<parameter name="instance-identifier" value="WEB1" />

<parameter name="is-cluster" value="false" />

<parameter name="web-real-name" value="Default Web Site" />

<parameter name="web-server-version" value="6.x" />

<parameter name="web-application-used" value="Web" />

<parameter name="install-filters" value="true" />

<parameter name="install-instrumentation" value="true" />

<parameter name="install-dynamic-instrumentation" value="true" />

<parameter name="web-collect-extended-information" value="false" />

<parameter name="web-ports" value="port=80;ip=server1;ssl=true"/>

<parameter name="web-iis-instance-number" value="1"/>

<parameter name="installation-cd-path" value="d:\"/>

</parameters>

 

Table 2-13    Elements of the Precise for Web parameter file

Element    Description

installation-cd-path    Indicates the absolute path to the folder where the Precise v9.6 download was downloaded to.

Values: String

Mandatory: Yes

setup-process    Setup process. always apptier-WW

Mandatory: Yes

setup-mode    Setup Mode

Values: install, edit, uninstall

Mandatory: Yes

collector-server-machine-name    Name of the server of the Collector.

Values: String

Mandatory: Yes

instance-name    The unique name of the Web server instance as identified on the Web server. This unique name helps to distinguish between several instances.

Values: String

Mandatory: No. This parameter is only relevant when the setup-mode is uninstall

instance-identifier    Used to create the instance name.

Values: String

Mandatory: Yes

is-cluster    Indicates that this instance is part of a cluster.

Values: (true/false). Can only be set to true for WebLogic and WebSphere.

Mandatory: Yes

show-historical-data    Indicates if historical data from the deleted instance is shown (true) or deleted (false)

Values: true/false

Mandatory: No. This parameter is only relevant when the setup-mode is uninstall.

web-type    Indicates type of server where the Web server instance is running.

Values: IIS, Apache, iPlanet, WebLogic, WebSphere, Tomcat, Sun ONE, SAP WAS J2EE, Oracle AS, Other J2EE, Other.

Mandatory: Yes

web-configuration-file    The full path for a Web server configuration file.

Values: String

Mandatory: Yes for Web Servers - Apache, iPlanet, WebLogic, Sun ONE, WebSphere, Tomcat, Oracle AS.

Mandatory: Web Servers - IIS, Other, Other J2EE, SAP WAS J2EE should all be specified as empty parameter.

web-apache-configuration-file    The full path for an Apache HTTP Web server configuration file.

Values: String

Mandatory: Yes, only for Oracle AS servers.

web-server-version    The Web server version.

Values: String

For IIS: Mandatory: Yes Versions: 5.x, 6.x

For Other, Other J2EE, SAP WAS J2EE. Mandatory: No

For Apache: Mandatory: Yes. Versions: 1.3.x, 2.0.x, 2.2.x

For WebLogic: Mandatory: Yes. Versions: 8.x, 9.x, 10.x

For WebSphere: Mandatory: Yes. Versions: 6.0, 6.1-6.x, 7.x

For Tomcat: Mandatory: Yes. Versions: 5.x, 6.x

For iPlanet: Mandatory: Yes Version: 6.x

For Sun ONE: Mandatory: Yes Version: 6.1

For Oracle AS: Mandatory: Yes. Version: "9.0.4.0.1 - 10.1.3" (Notice the additional spaces)

web-real-name    The IIS Web site name.

Values: String

Mandatory: Yes, only for IIS servers.

web-iis-instance-number    The IIS Web site number.

Values: String

Mandatory: Yes, only for IIS servers.

web-application-used    The application served by this Web server site.

Values: Web Siebel PeopleSoft

Mandatory: Yes

web-application-used-version    The application version served by this Web server site.

Values: String

For PeopleSoft:

Mandatory: Yes

Values:

■    If the monitored web server is WebSphere: "8.1 - 8.49"

■    If the monitored web server is WebLogic 8.x, 9.x or 10.x: "8.44 - 8.49"

■    If the monitored web server is Oracle Application Server: "8.44 - 8.49"

■    If the monitored web server is "Other J2EE": "8.1 - 8.49" For Web:

Values: Do not enter a value.

For Siebel:

Mandatory: Yes

Values: "7.5 - 7.7"

install-filters*    Indicates whether to install a filter on the Web server to collect server-side performance information.

Values: true, false

Mandatory: Yes

NOTE: Note: Dependent on Web server type (some types do not support this, some force this installation).

install-dynamic-instrumentation*    Indicates whether to perform dynamic instrumentation.

Values: true, false

Mandatory: Yes, only if "install-instrumentation" is true.

NOTE: Dependent on Web server type (some types do not support this, some force this installation).

web-ports*    The ports to be used by the Web Tier Collectors. Use two pipelines "||" as a separator between the ports. Specify at least one port.

Values: port=port number;ip=[ip value|ALL];host-header=host headers;ssl=[true|false] (for example: port=3333;ip=ALL;host-header=srv2;ssl=true||port=4444;ip=ALL;host-header=srv1;ssl=true).

Mandatory: Yes, if install-network is true and is-cluster is false.

web-server-bits    Web server bits.

Values: 32, 64

Mandatory: Yes for Web Servers - Apache, iPlanet.

web-server-root    The root of the Web site root.

Mandatory: Yes, only for an Other Web server type.

web-ssl-client-certification-path    full path to the client certificate file

Values: String

Mandatory: Yes if "web-ssl-use-client-certification" is true

web-server-i3-user-name    Web sever client name.

Values: String

Mandatory: Yes if "web-server-uses-authentication" is true

web-server-i3-password(encrypted)    Web server encrypted password.

Values: String

Mandatory: Yes if "web-server-uses-authentication" is true

Alternatively the web-server-i3-clear-password can be used, allowing you to specify a clear password instead of an encrypted string. For more information, see Encrypt command on page 148.

 

web-server-domain    Web server domain. Values: String

Mandatory: Yes if "web-server-uses-authentication" is true

web-server-method    Web server method.

Values: Basic, Digest, NTLM

Mandatory: Yes if "web-server-uses-authentication" is true

web-ssl-client-certification-password

(encrypted)    Encrypted password for the client certificate

Values: String

Mandatory: No

Alternatively the web-ssl-client-certification-clear-password can be used, allowing you to specify a clear password instead of an encrypted string. For more information, see Encrypt command on page 148.

 

web-ssl-client-certification-key-path    Full path to the client certificate private key file

Values: String

Mandatory: No

 

web-server-uses-authentication    Is the web server requires client authentication to establish a connection

Values: true\false

Mandatory: No

apptier-name    Name of the Tier for the added instance.

Values: String

Mandatory: No

environment-name    Name of the application for the added instance.

Values: String

Mandatory: Yes, for a federation installation

install-alert-customized    Value: true/false

Mandatory: No

Set to true to in case you want to have customized alerts metrics for this instance.

web-site-name    Site name, sometimes called context root.

Values: String

Mandatory: No

web-use-special-ssl-configuration    The only way to connect to the web server is using a secured connection (SSL).

Values: true\false

Mandatory: No

web-special-ssl-ciphers    Cipher list.

Values: Specify the ciphers to be used Comma separated.

Mandatory: No

web-ssl-use-client-certification    Specifies whether the web server requires the client certificate to have a certificate to establish a connection.

Values: true\false

Mandatory: No

install-network    Indicates whether to correlate the data collected by the Web server filter with the data collected by the Insight Savvy for Network.

Values: true, false

Mandatory: No

Installing Precise for Microsoft .NET with the Precise CLI utility

Installing Microsoft .NET Collectors on a server enables you to sample Microsoft .NET instances on the server. A Microsoft .NET Tier Collector can be installed only on servers running Microsoft .NET instances.

Before installing a Microsoft .NET Tier Collector with the Precise CLI utility, verify the following issues:

•    The Precise Listener on the target server on which the Precise for Microsoft .NET agent is to be installed, was installed.

 

To install Precise for Microsoft .NET with the Precise CLI utility

1.    Create the Precise for Microsoft .NET parameter file and save it to the <precise_root> folder on the main Precise FocalPoint. For more information, see About the Precise for Microsoft .NET parameter file on page 42.

2.    Run the following command from the <precise_root> folder on the main Precise FocalPoint to execute the Precise CLI utility installation script. Use the Precise user that was created when the Precise server was defined.

Windows    infra\bin\psin_cli.bat

i3-user <user_name>

{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}

-action setup

-parametersfile <precise_for_microsoft _.net_installation_parameters_file_name>

UNIX    ./infra/bin/psin_cli.sh

-i3-user <user_name>

{-i3-encrypted-password <encrypted_password>| -i3-clear-password <clear_password>}

-action setup

-parametersfile <precise_for_microsoft_.net_installation_parameters_file_name>

About the Precise for Microsoft .NET parameter file

You need to prepare the Precise for Microsoft .NET parameter file by creating an XML file with elements that represent the installation parameters and inserting the appropriate values.

The following table describes the updated elements of the Microsoft .NET parameter file. Parameters file example:

<root>

<parameter name="setup-process" value="apptier-DN"/>

<parameter name="collector-server-machine-name" value="serverwin1004"/>

<parameter name="instance-name" value="MyInstance"/>

<parameter name="type" value="web" />

<parameter name="application-name" value="IIS5" />

<parameter name="process-name" value="aspnet_wp.exe" />

<parameter name="installation-cd-path" value="d:\"/>

</root>

Table 2-14    Elements of the Precise for Microsoft .NET parameter file

Element    Description

installation-cd-path    Indicates the absolute path to the folder where the Precise v9.6 download was downloaded to.

Values: String

Mandatory: Yes

setup-process    Setup process. always apptier-DN

Mandatory: Yes

setup-mode    Setup mode.

Values: install, edit, uninstall

Mandatory: Yes

collector-server-machine-name    Name of the server on which the Precise for Microsoft .NET Collector will be installed.

Values: String

Mandatory: Yes

instance-name    The unique alphanumeric string used by Precise for Microsoft .NET and Insight to identify the monitored application instance.

Values: String using English characters.

Mandatory: Yes

type    Indicates the type of the Microsoft .NET instance.

Available types are as follows:

■    web. Select this option when monitoring an ASP.NET application.

■    general. Select this option when monitoring other Microsoft .NET processes.

Mandatory: Yes

application-name    If this instance is an ASP Microsoft .NET instance, the value for this field depends on the Internet Information Server (IIS) type: IIS5, or IIS6.

For a regular Microsoft .NET instance the field should be left empty.

Values: IIS5, IIS6, or empty

Mandatory: Yes, for ASP Microsoft .NET instances. For all other instances, this must remain empty.

process-name*    Indicates the name of the .NET process executable file.

For a regular Microsoft .NET instance, the field should include the path and name of the Microsoft .NET executable file.

For an ASP Microsoft .NET instance, the value for this field depends on the type of Internet Information Server (IIS) as follows:

■    For IIS 5:  aspnet_wp.exe

■    For IIS 6:  w3wp.exe

process-name can only be updated after installation if the instance type is general.

Values: String

Mandatory: Yes

apptier-name    Name of the Tier.

Values: String

Mandatory: No

environment-name    Name of the application.

Values: String

Mandatory: Yes, for a federation installation

install-alert-customized    Values: true/false

Mandatory: No

Set to true to in case you want to have customized alerts metrics for this instance.

application-pool    Specifies the application pool(s) to be monitored by this instance. Use "*" to specify multiple application pools for monitoring.

Values: String

Mandatory: No

Installing Precise for SQL Server with the Precise CLI utility

Installing SQL Server Tier Collectors on a server enables you to sample SQL Server instances on the server. An SQL Server Tier Collector can be installed on Windows servers running SQL Server instances, or it can be installed on any Windows server and the SQL Server instances can be sampled remotely.

Before installing a SQL Server Tier Collector with the Precise CLI utility, verify the following issues:

•    The Precise for SQL Server FocalPoint was installed.

•    The Precise Listener on the target server on which the SQL Server Tier Collector is to be installed, was installed.

 

To install Precise for SQL Server with the Precise CLI utility

1.    Create the Precise for SQL Server parameter file and save it to the <precise_root> folder on the main Precise FocalPoint. You can also set up this file in advance. See About the Precise for SQL Server parameter file on page 44.

2.    Run the following command from the <precise_root> folder on the main Precise FocalPoint to execute the Precise CLI utility installation script. Use the Precise user that was created when the Precise server was defined.

Windows    infra\bin\psin_cli.bat

-i3-user <user_name>

{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}

-action setup

-parametersfile <precise_for_sql_server_installation_parameters_file_name>

UNIX    ./infra/bin/psin_cli.sh

-i3-user <user_name>

{-i3-encrypted-password <encrypted_password>| -i3-clear-password <clear_password>}

-action setup

-parametersfile <precise_for_sql_server_installation_parameters_file_name>

About the Precise for SQL Server parameter file

You need to prepare the Precise for SQL Server parameter file by creating an XML file with elements that represent the installation parameters and inserting the appropriate values in them.

The following is an example of a Sql Server instance parameters file:

<parameters>

<parameter name="installation-cd-path" value="d:\"/>

<parameter name="setup-process" value="apptier-SQ" />

<parameter name="setup-mode" value="install" />

<parameter name="collector-server-machine-name" value="server1" />

<parameter name="instance-name" value="SERVER1" />

<parameter name="sqlserver-authentication" value="sql" />

<parameter name="sqlserver-i3-user" value="sa" />

<parameter name="sqlserver-i3-clear-password" value="" />

</parameters>

The following table describes the updated elements of the parameter file. Field names marked with an asterisk (*) can be updated after installation.

Table 2-15    Elements of the Precise for SQL Server parameter file

Element    Description

installation-cd-path    Indicates the absolute path to the folder where the Precise v9.6 download was downloaded to.

Values: String

Mandatory: Yes

setup-process    Setup process. always apptier-SQ Mandatory: Yes

setup-mode    Setup mode.

Values: install, edit, uninstall

Mandatory: Yes

instance-name    SQL Server instance name. (Must always be uppercase).

Values: String

Mandatory: Yes

collector-server-machine-name    Name of the server on which the Precise for SQL Server Collector will be installed.

Values: String

Mandatory: Yes

os-user    Specifies the Windows user that the SQL Server Collector should use.

Values: String

Mandatory: Only if the instance does not reside on the same server as the collector, or when the PMDB uses Windows authentication.

os-domain    Specifies the Windows user’s domain that the SQL Server Collector should use.

Values: String

Mandatory: Only if the instance does not reside on the same server as the collector, or when the PMDB uses Windows authentication.

os-encrypted-password    Specifies the Windows password that the SQL Server Collector should use.

Values: Encrypted String. For more information, see Encrypt command on page 148.

Mandatory: Only if the instance does not reside on the same server as the collector, or when the PMDB uses Windows authentication. Alternatively the os-clear-password parameter can be used, allowing you to specify a clear password instead of an encrypted string.

sqlserver-authentication*    Specifies how the Collector will connect to the SQL Server instance. (Windows authentication/SQL authentication).

Values: sql, nt

Mandatory: Yes

sqlserver-i3-user*    User name.

Values: String

Mandatory: Only mandatory if authentication is ‘sql’.

sqlserver-i3-encrypted-password*    Password for SQL Server.

Values: Encrypted String.

Mandatory: Only mandatory if authentication is ‘sql’. For more information, see Encrypt command on page 148.

Alternatively the sqlserver-i3-clear-password can be used, allowing you to specify a clear password instead of an encrypted string.

install-storage-type*    Install Precise for Storage.

Values: empty - for no Precise for Storage SQWIN - for Windows storage

Mandatory: No

install-psoft-extension*    Installs the PeopleSoft extension.

Values: true, false

Mandatory: No

sqlserver-sap-system-name    The SAP system name.

Values: String

Mandatory: Yes, if install-sap-inter-point is true.

sqlserver-sap-default-application-se rver    The Application server name used to create the first connection with the SAP system.

Values: String

Mandatory: Yes, if install-sap-inter-point is true.

You can only specify one default-app-server and app-rout-string.

sqlserver-sap-system-number    The SAP system number.

Values: String

Mandatory: Yes, if install-sap-inter-point is true.

sqlserver-sap-user    The SAP system user name.

Values: String

Mandatory: Yes, if install-sap-inter-point is true.

sqlserver-sap-encrypted-password    The SAP system encrypted password.

Values: Encrypted String

Mandatory: Yes, if install-sap-inter-point is true. For more information, see Encrypt command on page 148.

Alternatively the sqlserver-sap-clear-password can be used, allowing you to specify a clear password instead of an encrypted string.

sqlserver-sap-client-id    The client ID used to create the first connection with the SAP system.

Values: String

Mandatory: Yes, if install-sap-inter-point is true.

install-sap-inter-point    Indicates whether you want to install SAP Interpoint

Values: true, false

Mandatory: No

apptier-name    Name of the Tier.

Values: String

Mandatory: No

environment-name    Name of the application.

Values: String

Mandatory: Yes, for a federation installation

os-user    Specifies the Windows user that the collector should use.

Values: String

Mandatory: Must be specified if the PMBD uses Windows authentication.

os-domain    Specifies the Windows user’s domain that the collector should use.

Values: String

Mandatory: Must be specified if the PMBD uses the Windows authentication.

os-encrypted-password    Specifies the Windows password that the Collector should use.

Values: Encrypted String. For more information, see Encrypt command on page 148. Alternatively the os-clear-password parameter can be used, allowing you to specify a clear password instead of an encrypted string.

Mandatory: Must be specified if the PMBD uses Windows authentication.

install-alert-customized    Values: true/false

Mandatory: No

 

Precise. Performance intelligence from click to storage. Learn more > >
  • No labels