This section includes the following topics:
- Installing the Precise Framework
- Installing Precise FocalPoints
- Installing Servers
- Installing secured servers with the Precise CLI utility
- Updating services Authentication using the Precise CLI Utility
- Installing a Tier with the Precise CLI utility
- Extricate command
- Edit & uninstall
- Installing a new instance while keeping historical data from an old instance
Installing the Precise Framework
The Precise Framework can be installed directly from the Precise v9.6 download onto the Precise FocalPoint server. You can use the Precise CLI utility to install the following Framework components:
- Precise FocalPoint
- PMDB FocalPoint
- Alerts FocalPoint
- Report Manager FocalPoint
- Insight FocalPoint
- TPM FocalPoint
For information on manually installing the PMDB schemas, see the Precise Installation Guide.
How to install the Precise Framework
Install the Precise Framework by performing the following steps:
- Prepare XML parameters file to specify the Framework installation parameters and log in to the server on which you have planned to install the Precise FocalPoint.
- On this server, run the following command from the
<precise_root>
folder to install the CLI utility installation script:
Windows <installation_DVD>
\CLI\psin_framework_install.bat
<full_path_to_XML_parameters_file>
UNIX <installation_DVD>
/CLI/psin_framework_install.sh
<full_path_to_XML_parameters_file>
After running the script, you may be required to perform manual post-installation tasks to complete the installation. - If an error occurs, fix the problem and rerun the installation scripts. (In the case of an error, there is no need to delete the installation files.) If a critical error occurs before the Precise FocalPoint is installed, an error message is displayed. At the end of CLI utility installation, a message appears "Installation complete - check logs for details". The relevant logs for installation are as follows:
- <precise_root>/logs/psin_framework_install.out
- <precise_root>/logs/infra.CLI.log
If installation is successful, a message appears "Framework install setup process done".
For Windows Server which has the User Account Control enabled, you must run this command using Administrator permissions: Click Start Menu, right-click Command Prompt, click "Run as administrator", click Continue button, to approve the operation. Run the command specified above.
About the Precise Framework parameter file
You need to prepare the Framework parameter file by creating an XML file with tags that represent the installation parameters and inserting the appropriate values.
The following is an example of a server parameters file:
<parameters>
<parameter name="setup-process" value="framework"/>
<parameter name="setup-mode" value="install"/>
<parameter name="installation-cd-path" value="d:\"/>
<parameter name="i3fp-server-machine-name" value="server1"/>
<parameter name="dbms-type" value="mssql"/>
<parameter name="dbms-instance" value="DATABASE1"/>
<parameter name="dbms-database" value="PWV8"/>
<parameter name="dbms-dba-user" value="pwv8"/>
<parameter name="dbms-dba-clear-password" value="mypass"/>
<parameter name="gui-port" value="20820"/>
<parameter name="gui-shutdown-port" value="20821"/>
<parameter name="server-machine-installation-folder-server1" value="d:\precise"/>
<parameter name="server-machine-port-server1" value="20802"/>
</parameters>
The parameters file is an XML file containing a list of parameters for a Precise framework installation.
Table 2-1 Elements of the Precise framework parameter file
Element | Description |
---|---|
server-machine-installation-folder-server-name | Indicates the folder in which Precise installation files are stored. Values: String Mandatory for Precise FocalPoint Server: Yes Mandatory for other servers: Yes, unless you prefer to perform a manual installation. |
server-machine-port-server-name | Port of the Precise Listener on the local server. Values: Numeric 1025–65535 Mandatory: Yes |
setup-process | Marked always as framework. Mandatory: Yes |
setup-mode | Must be in one of the following modes:
Mandatory: Yes |
installation-cd-path | Indicates the absolute path to the folder where the Precise v9.6 download was downloaded to. Values: String Mandatory: Yes |
i3fp-server-machine-name | Name of the Precise FocalPoint server. The name must be written in lowercase letters only. Can be a fully qualified name or IP address. Values: String Mandatory: Yes |
gui-port | Port of the Graphics User Interface (GUI) server. Values: Numeric 1025–65535 (must not be identical to other ports specified) Mandatory: Yes |
gui-shutdown-port | Local port for controlling the GUI. Values: Numeric 1025 -65535 (must not be identical to other ports specified) Mandatory: Yes |
server-machine-service-unique-id-server-name | A unique name used in the installation of all Precise agents. This is used if you want to support more than one Precise installation system on the server (for example, in cluster applications). Relevant only for Windows servers. Values: Alphanumeric Mandatory: No |
pw-server-machine-name | Name of the PMDB FocalPoint server. The name must be written in lowercase letters only. Values: String Mandatory: No, defaults to the Precise FocalPoint. |
alerts-server-machine-name | Name of the Alerts FocalPoint server. The name must be written in lowercase letters only. Values: String Mandatory: No, defaults to the Precise PMDB FocalPoint. |
foresight-server-machine-name | Name of the Report Manager FocalPoint server. The name must be written in lowercase letters only. Values: String Mandatory: No, defaults to the Precise PMDB FocalPoint. |
insight-server-machine-name | Name of the Insight FocalPoint server. The name must be written in lowercase letters only. Values: String Mandatory: No, defaults to the Precise PMDB FocalPoint. |
The Framework CLI supports installing the framework FocalPoint on different servers. If the servers are UNIX servers, the framework's servers will be automatically installed by the framework CLI (you need to supply user and password parameters for each UNIX server). If the servers are Windows servers and different servers are required for the framework FocalPoints, perform the steps described in the following procedure.
To install the framework FocalPoint on different Windows servers
- Only install the Precise FocalPoint using the framework CLI command.
- Install the other FocalPoints with the Add Server CLI command. See Installing Servers.
- Install all required framework FocalPoints with the framework CLI command.
Installing the PMDB FocalPoint using an Oracle database
Additional parameters are needed for installing the PMDB FocalPoint on an Oracle database.
The following table lists the additional parameters needed for a PMDB installation using an Oracle database.
Table 2-2 Additional parameter file elements for the PMDB on an Oracle database
Element | Description |
---|---|
dbms-type | Marked always as oracle. Values: String Mandatory: Yes |
dbms-server | Name of the Oracle database server. Values: String Mandatory: Yes |
dbms-instance | Oracle instance name (SID). Values: String Mandatory: Yes |
dbms-port | Oracle instance Listener port. Values: Integer Mandatory: Yes |
dbms-dba-user | User name for the Oracle user with DBA privileges. Will only be used during installation. Values: String Mandatory: Yes, if manual-schema is set to false. |
dbms-tablespace-large-name | Name of the large tablespace that will be used by PMDB. Values: String Mandatory: No Default value: PRECISE_PW_TAB_LARGE |
dbms-tablespace-medium-name | Name of the medium tablespace that will be used by PMDB. Values: String Mandatory: No Default value: PRECISE_PW_TAB_MEDIUM |
dbms-tablespace-small-name | Name of the small tablespace that will be used by PMDB. Values: String Mandatory: No Default value: PRECISE_PW_TAB_SMALL |
dbms-tablespace-infral-name | Name of the infra tablespace that will be used by PMDB. Values: String Mandatory: No Default value: PRECISE_PW_TAB_INFRA |
dbms-tablespace-sts-name | Name of the sts tablespace that will be used by PMDB. Values: String Mandatory: No Default value: PRECISE_PW_TAB_STS |
dbms-tablespace-large-initial-size | Initial size for the large tablespace. Values: Integer Mandatory: No Default value: 64 |
dbms-tablespace-medium-initial-size | Initial size for the medium tablespace. Values: Integer Mandatory: No Default value: 64 |
dbms-tablespace-small-initial-size | Initial size for the small tablespace. Values: Integer Mandatory: No Default value: 64 |
dbms-tablespace-infra-initial-size | Initial size for the infra tablespace. Values: Integer Mandatory: No Default value: 64 |
dbms-tablespace-sts-initial-size | Initial size for the STS tablespace. Values: Integer Mandatory: No Default value: 32 |
dbms-tablespace-large-uniform-size | Uniform size for the large tablespace. Values: Integer Mandatory: No Default value: 2048 |
dbms-tablespace-medium-uniform-size | Uniform size for the medium tablespace. Values: Integer Mandatory: No Default value: 512 |
dbms-tablespace-small-uniform-size | Uniform size for the small tablespace. Values: Integer Mandatory: No Default value: 80 |
dbms-tablespace-infra-uniform-size | Uniform size for the infra tablespace. Values: Integer Mandatory: No Default value: 80 |
dbms-tablespace-sts-uniform-size | Uniform size for the STS tablespace. Values: Integer Mandatory: No Default value: 256 |
dbms-tablespace-large-extent-size | Extent size for the large tablespace. Value: Integer Mandatory: No Default value: 512 |
dbms-tablespace-medium-extent-size | Extent size for the medium tablespace. Value: Integer Mandatory: No Default value: 512 |
dbms-tablespace-small-extent-size | Extent size for the small tablespace. Value: Integer Mandatory: No Default value: 512 |
dbms-tablespace-infra-extent-size | Extent size for the infra tablespace. Value: Integer Mandatory: No Default value: 512 |
dbms-tablespace-sts-extent-size | Extent size for the sts tablespace. Value: Integer Mandatory: No Default value: 1024 |
dbms-ind-large-name | Name of the large index tablespace that will be used by PMDB. Values: String Mandatory: No Default value: PRECISE_PW_IND_LARGE |
dbms-ind-medium-name | Name of the medium index tablespace that will be used by PMDB. Values: String Mandatory: No Default value: PRECISE_PW_IND_MEDIUM |
dbms-ind-small-name | Name of the small index tablespace that will be used by PMDB. Values: String Mandatory: No Default value: PRECISE_PW_IND_SMALL |
dbms-ind-large-initial-size | Initial size for the large index tablespace. Values: Integer Mandatory: No Default value: 64 |
dbms-ind-medium-initial-size | Initial size for the medium index tablespace. Values: Integer Mandatory: No Default value: 64 |
dbms-ind-small-initial-size | Initial size for the small index tablespace. Values: Integer Mandatory: No Default value: 64 |
dbms-ind-large-uniform-size | Uniform size for the large index tablespace. Values: Integer Mandatory: No Default value: 1024 |
dbms-ind-medium-uniform-size | Uniform size for the medium index tablespace. Values: Integer Mandatory: No Default value: 256 |
dbms-ind-small-uniform-size | Uniform size for the small index tablespace. Values: Integer Mandatory: No Default value: 80 |
dbms-ind-large-extent-size | Extent size for the large index tablespace. Value: Integer Mandatory: No Default value: 512 |
dbms-ind-medium-extent-size | Extent size for the medium tablespace. Value: Integer Mandatory: No Default value: 512 |
dbms-ind-small-extent-size | Extent size for the small tablespace. Value: Integer Mandatory: No Default value: 512 |
manual-schema | Indicates if the schema should be manually installed. Values: true, false Mandatory: No. Default value: false |
is-partitioned | Indicates if the database contains partitioning. Values: true, false Mandatory: Yes, if manual-schema is true |
dbms-version | Database version. Values: 9i, 10g, 11g Mandatory: Yes, if manual-schema is true |
dbms-dba-encrypted-password | Password for the Oracle user with DBA privileges. Will only be used during installation. Values: Encrypted String Mandatory: Yes, if manual-schema is set to false. Alternatively the dbms-dba-clear-password can be used, allowing you to specify a clear password instead of an encrypted string. For more information, see Encrypt command on page 148. |
dbms-i3-user | User name for the Precise user who owns the PMDB schema. Values: String Mandatory: Yes |
dbms-i3-encrypted-password | Password for the Precise user with PMDB privileges. Values: Encrypted String Mandatory: Yes Alternatively the dbms-i3-clear-password can be used, allowing you to specify a clear password instead of an encrypted string. For more information, see Encrypt command on page 148. |
dbms-tablespace-temp-name | Storage parameter name for the Precise for Oracle schema. Indicates Temporary tablespace name. Values: String Mandatory: No Default value: PRECISE_PMBD_TMP |
dbms-tablespace-temp-file | Storage parameter for the Precise for Oracle schema. Indicates Temporary tablespace file. Values: String Mandatory: No Default value: PRECISE_PMBD_TMP |
dbms-tablespaces-folder | Storage parameter for the Precise for Oracle schema. Indicates the folder in which Tablespace datafiles are stored. Values: String Mandatory: Yes |
dbms-use-bigfile-for-tablespaces | Specify whether the tablespaces will be created as bigfiles. Values: true, false Mandatory: No Default value: true |
dbms-service | Specify the name of oracle service in case you want to use oracle cluster. Value: String Mandatory: No |
Installing the PMDB FocalPoint using an MS-SQL Server database
Additional parameters are needed for installing the PMDB FocalPoint on an MS-SQL Server database.
The following table lists the additional parameters needed for a PMDB installation using an MS-SQL Server database.
Table 2-3 Additional parameter file elements for the PMDB on an MS-SQL Server database
Element | Description |
---|---|
manual-schema | Indicates if the schema should be manually installed. Values: true, false Mandatory: No. Default value: false |
is-partitioned | Indicates if the database contains partitioning. Values: true, false Mandatory: Yes, if manual-schema is true |
dbms-version | Database version. Values: 2005, 2008 Mandatory: Yes, if manual-schema is true |
dbms-type | Marked always as SQL Server (mssql). Mandatory: Yes |
dbms-instance | MS-SQL Server instance name. (Must always be uppercase). Values: String Mandatory: Yes |
dbms-use-win-authentication | Indicates whether the PMBD will be connected using OS authentication. Values: Boolean Mandatory: No Default value: false All focals must be on the Windows server and the service must be configured to run with the user that has privileges on the PMDB. When using windows authentication, the CLI must be run by a user with permissions to connect to the SQL Server database. |
dbms-database | Name of the MS-SQL Server database. Values: String Mandatory: Yes |
dbms-dba-user | User name for the MS-SQL Server user with DBA privileges to install the schema. Values: String Mandatory: Not mandatory if dbms-use-win-authentication is true. |
dbms-dba-encrypted-password | Password for the MS-SQL Server user with DBA privileges. Values: Encrypted String Mandatory: Not mandatory if dbms-use-win-authentication is true. Editable: No Alternatively the dbms-dba-clear-password can be used, allowing you to specify a clear password instead of an encrypted string. For more information, see Encrypt command on page 148. |
dbms-file-groups | All tables will be created under this file group. Values: String Mandatory: No |
dbms-collation | New database will be created using this collation. Values: String Mandatory: No Default value: SQL_Latin1_General_CP1_CS_AS |
dbms-data-growth | New database data file auto growth size in MB. Values: Integer Mandatory: No Default value: 512 |
dbms-data-size | New database data file size in MB. Values: Integer Mandatory: No Default value: 1024 |
dbms-data-path | Folder under the database server where the data file will be created. Values: String Mandatory: Yes, if the dbms-database parameter value is a database which does not exist. |
dbms-log-path | Folder under the database server where the database log file will be created. Values: String Mandatory: Yes, if the dbms-database parameter value is a database which does not exist. |
dbms-log-size | New database log file size in MB. Values: Integer Mandatory: No Default value: 512 |
dbms-log-growth | New database log file auto growth size in percent. Values: Integer Mandatory: No Default value: 10 |
Installing additional parameters to servers where FocalPoints are installed
The following table lists the additional parameters needed for server installation, wherever FocalPoints are installed. These are required only if when installing the Framework FocalPoint on servers other than the Precise FocalPoint. In such cases specify the parameters below for each server and replace server-name (italic) with the real server name.
Table 2-4 Additional parameter file elements for server installation
Element | Description |
---|---|
server-machine-port-server-name | Port of the Precise Listener on the server. Values: Numeric 1025 -65535 Mandatory: Yes |
server-machine-installation-folder-server-name | Indicates the folder in which Precise installation files are stored. Values: String Mandatory: Yes, unless you prefer to perform a manual server installation. |
server-machine-use-communication-relay-server-name | Indicates whether this server should use relay communication. Select this option if the server resides behind a firewall. Values: (true/false) Mandatory for other servers: No |
server-machine-flavor-server-name | Type of server. Must be in one of the following servers:
Mandatory: Yes, unless you prefer to perform a manual server installation. |
server-machine-install-user-server-name | User name required to install the Precise Listener on the server. Will only be used during installation. Values: String Mandatory for other servers: Yes, unless you prefer to perform a manual server installation. |
server-machine-install-encrypted-pass word-server-name | Password for the user, required for using Precise Listener services on the server. Values: Encrypted String Mandatory: Yes, unless you prefer to perform a manual server installation. Alternatively the server-machine-install-clear-password-server-name can be used, allowing you to specify a clear password instead of an encrypted string. For more information, see Encrypt command on page 148. |
server-machine-service-authentication- mode-server-name | Server authentication mode. Precise services are using LocalSystem account. to specify other user account specify "user", and use:
Values: String Mandatory: No |
server-machine-service-authentication- user-server-name | User account name for Precise services on the server. Mandatory: Only if server-machine-service-authentication-mode-server-name is set to "user". Values: String |
server-machine-service-authentication- encrypted-password-server-name | Password for the user specified in server-machine-service-authentication-user-server-name. Values: Encrypted String Mandatory: Only if server-machine-service-authentication-mode-server-name is set to "user". Alternatively the server-machine-service-authentication-clear-password-server-name can be used, allowing you to specify a clear password instead of an encrypted string. For more information, see Encrypt command on page 148. |
server-machine-service-authentication- domain-server-name | Domain of user specified in server-machine-service-authentication-user-server-name. Values: String Mandatory: Only if server-machine-service-authentication-mode-server-name is set to "user". |
server-machine-bind-listener-address-server-name | Indicates whether the Precise Listener on this server should bind the specified server name or all the addresses on the given port. Values: true/false Mandatory: No |
Installing Precise FocalPoints
Installing a Precise FocalPoint on a server
When using the CLI for installation, you must explicitly install the FocalPoint. This is unlike the GUI-based installation, in which FocalPoints are automatically installed with the first instance relevant. To install a Precise FocalPoint, the you should create an installation parameters file and run the Precise CLI utility installation script on the main Precise FocalPoint.
To install a Precise FocalPoint on a server
- Build a parameter XML file to be used as input for the installation scripts.
- Run the following command from the <
precise_root
> folder on the main Precise FocalPoint.
Windows infra\bin\psin_cli.bat
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <path_to_parameters_file>
UNIX ./infra/bin/psin_cli.sh
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <path_to_parameters_file>
About the Precise FocalPoint parameter file
You need to prepare the Precise FocalPoint parameter file by creating an XML file with tags that represent the installation parameters and inserting the appropriate values.
The following is an example of a Precise FocalPoint parameters file that installs the Oracle FocalPoint on server1:
<parameters>
<parameter name="setup-process" value="focal-OR"/>
<parameter name="setup-mode" value="install"/>
<parameter name="focal-server-machine-name" value="server1"/>
<parameter name="installation-cd-path" value="\\filesvr\Precise i3\ installation"/>
</parameters>
The following table lists the needed parameters for a Precise FocalPoint installation. The parameter format is:
<parameters>
<parameter name="..." value="..."/> ...
</parameters>
Table 2-5 Parameter file elements for a Precise FocalPoint installation
Element | Description |
---|---|
setup-process | Indicates the name of the setup process Values: String; focal-<PRODUCT CODE>, for example: focal-JE, focal-OR. For more information, see Product Codes on page 175. Mandatory: Yes Editable: No |
setup-mode | Must be in one of the following modes:
Mandatory: Yes Editable: Yes |
focal-server-machine-name | Name of the server where the Precise FocalPoint will be installed. The name must be written in lowercase letters only. Can be a fully qualified name or IP address. Values: String Mandatory: Yes Editable: No |
installation-cd-path | Indicates the absolute path to the folder where the Precise v9.6 download was downloaded to. Values: String Mandatory: Yes Editable: Yes |
Installing Servers
The first stage in a server installation using the CLI utility requires installing and registering the server in Precise. The server is registered in the Precise database, a Precise Listener is started on the server, and communication between the Precise FocalPoint and the Precise Listener is enabled.
To promote efficiency, servers can also be installed automatically. For more information, see Auto Deployment on page 108.
Before installing a server using the CLI utility, verify the following issues:
- The Precise communication port is open in both directions (between the Precise FocalPoint server and the target server).
- CLI can handle installation packages. For more information, see Installation packages on page 8. To install the servers with the CLI utility
Run the following command on the main Precise FocalPoint server:
Windows infra\bin\psin_cli.bat
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action list-required-files-for-new-server
-bits <new server bits (32/64)>
-os <os _type>
UNIX ./infra/bin/psin_cli.sh
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action list-required-files-for-new-server
-bits <new server bits (32/64)>
-os <os_type>
The CLI creates an XML file containing the list of required installation packages for the server.
Table 2-6 Server InstallationElement Description i3-user See Authenticate to CLI utility on page 8. i3-encrypted-password See Authenticate to CLI utility on page 8. action Always list-required-files-for-new-server.
Mandatory: Yesbits The OS bits in the new added server.
Values:32 or 64
Mandatory: Yesos The added server OS.
Values: See Operating System Type and Flavor on page 176.
Mandatory: Yes- On the new server create the installation folder and create new sub folder under it: distribution.
- Copy the files specified the XML file created in Step 1 to the new server in the
<precise_root>/distribution - Login to the server using the Precise user
CD <precise_root> - Run the following command:
Windows distribution\psin_ba_WIN.exe -s
UNIX ./distribution/psin_ba_<os_type> -s
For more information, see Operating System Type and Flavor on page 176.
Note the -s argument - For each of the other files you've copied, run the following command:
Windows infra\bin\psin_file_new.exe -manual -extract distribution\<the_file_name> -event install
UNIX ./infra/bin/psin_file_new -manual -extract distribution/<the_file_name> -event install - Create an XML file containing the relevant installation parameters. Place the file in <precise_root> folder on the target server. You can also set up this file in advance.
By default, installing an non-secured local server using the CLI is not enabled. To enable a non-secured CLI server installation, set the Precise registry parameter:
registry\products\infrastructure\setup\settings\enable-local-server-cli to true, and restart Precise FocalPoint. - Run the following command to execute the CLI utility installation script from the <precise_root> folder on the target server:
Windows infra\bin\psin_cli.bat
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup-server -parametersfile <server_installation_parameters_file_name>
UNIX ./infra/bin/psin_cli.sh
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup-server
-parametersfile <server_installation_parameters_file_name>
For Windows Server 2008 (Windows Longhorn) you must run this command using Administrator permissions: Click Start Menu, right-click Command Prompt, click Run as administrator, click Continue, to approve the operation. Run the command specified above.
Table 2-7 CLI utility installation script
Element | Description |
---|---|
i3-user | See Authenticate to CLI Utility on page 8. |
i3-encrypted-password | See Authenticate to CLI Utility on page 8. |
action | always setup-server Mandatory: Yes |
parametersfile | path to parameters file Mandatory: Yes |
About the server parameter file
You need to prepare the Server parameter file by creating an XML file with tags that represent the installation parameters and inserting the appropriate values.
The following is an example of a server parameter file:
<parameters>
<parameter name="setup-mode" value="install"/>
<parameter name="setup-process" value="server" />
<parameter name="installation-cd-path" value="d:\" />
<parameter name="handle-server-machine-name" value="poolserver5" />
<parameter name="server-machine-port-poolserver5" value="3002" />
<parameter name="server-machine-flavor-poolserver5" value="Windows" />
<parameter name="i3fp-server-machine-name" value="focalmachine" />
<parameter name="focalmachine-server-machine-port" value="20702" />
</parameters>
The following table describes the elements of the parameter file.
Table 2-8 Elements of the servers parameter file for product Collectors
Element | Description |
---|---|
setup-mode | Setup mode that is used. Values: install, edit, uninstall Mandatory: Yes |
setup-process | Setup process. Value: always server. Mandatory: Yes |
handle-server-machine-name | Name of the local server. Can be a fully qualified name or IP address. The server name must be recognized by the Precise FocalPoint server, for example, it should be registered in DNS. Values: String Mandatory: Yes |
server-machine-port-server-name | Port of the Precise Listener on the local server. Values: Numeric 1025–65535 Mandatory: Yes |
i3fp-server-machine-name | Name of the Precise FocalPoint server. Can be fully qualified name or IP address. The Precise FocalPoint server name must be recognized by the newly added server, for example, it should be registered in DNS. Values: String Mandatory: Yes |
server-machine-port-i3fp-server-name | Port of the Precise FocalPoint Listener. Replace i3fp-server-name with the name of Precise FocalPoint as shown in Precise GUI. Values: Numeric 1025–65535 Mandatory: Yes |
server-machine-use-communication-relay -server-name | The Communication Relay provides a solution to a firewall restrictions problem. For more details see the Precise Installation Guide. Value: (true/false) Mandatory: No. |
environment-name | Related application name. Values: String Mandatory: Yes, in case of federation installation. |
server-machine-service-authentication-user-server-name | User account name for Precise services on the server. Values: String Mandatory: Only if server-machine-service-authentication-mode-server-name is set to "user". |
server-machine-service-authentication-encrypted-password-server-name | Password for the user specified in server-machine-service-authentication-user-server-name. Values: Encrypted String Mandatory: Only if server-machine-service-authentication-mode-server-name is set to "user". Alternatively the server-machine-service-authentication-clear-password-server-name can be used, allowing you to specify a clear password instead of an encrypted string. For more information, see Encrypt command on page 148. |
server-machine-service-authentication-domain-server-name | Domain of user specified in server-machine-service-authentication-user-server-name. Values: String Mandatory: Only if server-machine-service-authentication-mode-server-name is set to "user". |
server-machine-service-unique-id-server-name | A unique services suffix used in the installation of all Precise agents allows installation of several Precise installations folders on the same server. Relevant only for Windows servers. Values: String Mandatory: No |
server-machine-service-authentication-mode-server-name | Server authentication mode. Precise services are using LocalSystem account. to specify other user account specify "user", and use: server-machine-service-authentication-user-server-name to specify the authentication details: Values: user or localsystem Mandatory: No |
server-machine-secured-protocol-server-name | The secured installation is using an existing security protocols and methods such as blowfish and SSH to ensure that the communication encryption keys are safely copied to the target server. Value: true, false Mandatory: No |
server-machine-security-clear-password-server-name | Security password. Value: String Mandatory: Only on secured remote Manual installation. |
server-machine-install-user-server-name | User name required to install the Precise Listener on the server. Will only be used during installation. Value: String Mandatory: Only on secured remote automatic installation. |
server-machine-install-encrypted-password-server-name | Password for the user, required for using Precise Listener services on the server. Values: Encrypted String Mandatory: Yes, unless you prefer to perform a manual server installation. Alternatively the server-machine-install-clear-password-server-name can be used, allowing you to specify a clear password instead of an encrypted string. For more information, see Encrypt command on page 148. |
server-machine-installation-folder-server-name | Indicates the folder in which Precise installation files are stored. Values: String Mandatory: Yes, unless you prefer to perform a manual server installation. |
server-machine-flavor-server-name | Type of server. Must be in one of the following servers: Windows, UNIX Values: String Mandatory: Yes |
server-machine-use-jre-server-name | Indicates whether a Java-based Listener will be installed on the server or not. A Java-based Listener is required for ShortTimeSlice support. Values: true, false. Default: true for servers whose OS supports JRE 1.6. You should use false if the server’s OS does not support JRE 1.6 or to reduce the memory footprint of the Precise Listener. Mandatory: No |
server-machine-bind-listener-address-server-name | Indicates whether the Precise Listener on this server should bind the specific server name or bind all the addresses on the given port. Values: true, false Mandatory: No |
server-machine-ssl-server-name | Indicates whether this Listener will function as an SSL Listener. An SSL Listener is necessary to communicate with remote monitored instances. Values: true, false Default: false Mandatory: No For more information, see J2EE Remote Instance Monitoring on page 112. |
server-machine-ssl-port-server-name | Indicates the SSL port this Listener will listen too. Values: Integer Default: 443 Mandatory: No For more information, see J2EE Remote Instance Monitoring on page 112. |
server-machine-consumer-server-name | Indicates whether this Listener will function as a consumer that will pull data from SSL Listeners. Values: true, false Default: false Mandatory: No For more information, see J2EE Remote Instance Monitoring on page 112. |
server-machine-consume-target-server-name | Indicates a target server that contains an SSL Listener. By setting this parameter, the installed server will consume remote data only from the specified target server. If this parameter is not specified and the server-machine-consumer-server-name is set to true, the installed server will consume data from all servers that contain SSL Listeners. This parameter should only be set if the server-machine-consumer-server-name is set to true and you want to pull data from a specific SSL Listener. The target server specified in this parameter must be defined as an SSL Listener. Values: String (server name). Mandatory: No For more information, see J2EE Remote Instance Monitoring on page 112. |
Installing secured servers with the Precise CLI utility
The server installation CLI described above, assumes it can use non-secured protocols such as telnet, and can transfer the communication encryption key as clear text over the network. If this is a problem, you can install the server using a secure CLI. The secured installation uses existing security protocols and methods such as blowfish and SSH to ensure that the communication encryption keys are safely copied to the target server. It’s possible that the secured server installation might require more manual action items than non-secure server CLI installation. You can use one of the following methods to perform secured server installation:
- Remote Automatic mode
- Local mode
Remote Automatic mode
This mode may be used only if the target server is a UNIX server that runs SSH (secured shell).
- Prepare the server parameters file and save it to the <precise_root> folder on the main Precise FocalPoint.
For more information, see Table 2-8 on page 22. Mandatory parameters for this installation method are:
server-machine-secured-protocol-server-name true server-machine-install-encrypted-password-server-name
server-machine-installation-folder-server-name
server-machine-flavor-server-name
server-machine-install-user-server-name
You must not supply:
server-machine-security-clear-password-server-name
- On the main Precise FocalPoint, run the following command from <precise_root> folder:
Windows infra\bin\psin_cli.bat
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <server_parameters_file_path>
UNIX ./infra/bin/psin_cli.sh
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <server_parameters_file_path>
Precise supports most of the common SSH for UNIX. If you are unable to install using the automatic mode, try the Local mode below.
Local mode
Use this mode for Windows server or when your server does not have SSH installed.
- Prepare server parameters file. For more information, see Table 2-8 on page 22.
Mandatory parameters for this installation are:
server-machine-secured-protocol-server-name true
On the main Precise FocalPoint server, run the following command from the <precise_root> folder:
Windows infra\bin\psin_cli.bat
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action secure-crypt-keys
-ba-secure-clear-password <security_password>
UNIX ./infra/bin/psin_cli.sh
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action secure-crypt-keys
-ba-secure-clear-password <security_password>
The command will generate a key file on the Precise FocalPoint server, under the products/i3fp/security/keys/ folder.
Table 2-9 Local modeElement Descriptions i3-user See Authenticate to CLI Utility on page 8. i3-encrypted-password See Authenticate to CLI Utility on page 8. action always secure-crypt-keys
Mandatory: Yes
ba-secure-encrypted-password Password used to encrypt the communication key, up to 8 characters.
Mandatory: Yes
Alternatively the i3clear-password can be used, allowing you to specify a clear password instead of an encrypted string.
- Copy and extract the server packages on the target server as specified in Installing Servers.
- Copy key file from:
products/i3fp/security/keys/keys/xml
on the main Precise FocalPoint to the target server, to the./infra
folder. - On the target server, run the following command from the <precise_root > folder:
Windows infra\bin\psin_infra.exe
-manual-extricate-crypt <security_password>
UNIX ./infra/bin/psin_infra
-manual-extricate-crypt <security_password>
The command will extricate the security keys on the target server. - On the target server, run the following command from the <precise_root> folder. For more information, see Installing Servers.
Windows infra\bin\psin_cli.bat
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup-server
-parametersfile <server_parameters_file_path>
UNIX ./infra/bin/psin_cli.sh
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup-server
-parametersfile <server_parameters_file_path>
Updating services Authentication using the Precise CLI Utility
To update the user authentication of your Precise Windows services, fill in the following authentication parameters and then run the server setup installation in edit mode.
server-machine-service-authentication-mode-server-name
server-machine-service-authentication-domain-server-name
server-machine-service-authentication-user-server-name
server-machine-service-authentication-encrypted-password-server-name
For parameter details, see Table 2-10 on page 28.
Installing a Tier with the Precise CLI utility
Once you installed the Precise framework, you can install the Tiers that comprise your Precise suite. Click on the relevant section below, for how to install your Tier using CLI:
- Installing Precise for Oracle with the Precise CLI utility
- Installing Precise for Storage with the Precise CLI utility
- Installing Precise for J2EE with the Precise CLI utility
- Installing Precise for Web with the Precise CLI utility
- Installing Precise for Microsoft .NET with the Precise CLI utility
- Installing Precise for SQL Server with the Precise CLI utility
- Installing Precise for SAP with the Precise CLI utility
- Installing Precise for Sybase with the Precise CLI utility
- Installing Precise for Sybase Replication Server with the Precise CLI utility
- Installing Precise for DB2 with the Precise CLI utility
- Installing a Tuxedo instance with the Precise CLI utility
- Installing a WebSphere MQ instance with the Precise CLI utility
- Installing an Oracle Applications instance with the Precise CLI utility
- Installing Other Tier Collectors with the Precise CLI utility
- Installing an OS instance with the Precise CLI utility
- Installing an extension for Siebel with the Precise CLI utility
- Installing Precise for vCenter Server with the Precise CLI utility
Installing Precise for Oracle with the Precise CLI utility
Before installing an Oracle instance with the Precise CLI utility, verify the following issues:
- The Precise for Oracle FocalPoint was installed.
- The Precise Listener on the target server on which the Precise for Oracle agent is to be installed was installed.
To install Precise for Oracle with the Precise CLI utility
- Create the Precise for Oracle parameter file and save it to the <precise_root> folder on the main Precise FocalPoint. For more information, see About the Precise for Oracle parameter file on page 28.
- Run the following command from the <precise_root> folder on the main Precise FocalPoint to execute the Precise CLI installation script.
Windows infra\bin\psin_cli.bat
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <precise_for_oracle_installation_parameters_file_name>
UNIX ./infra/bin/psin_cli.sh
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <precise_for_oracle_installation_parameters_file_name>
About the Precise for Oracle parameter file
You need to prepare the Precise for Oracle parameter file by creating an XML file with elements that represent the installation parameters and inserting the appropriate values.
The following is an example of a Precise for Oracle parameters file:
<parameters>
<parameter name="setup-process" value="apptier-OR"/>
<parameter name="setup-mode" value="install"/>
<parameter name="collector-server-machine-name" value="server5"/>
<parameter name="instance-name" value="ORCL"/>
<parameter name="oracle-home" value="C:\oracle\product\10.1.0\Db_1"/>
<parameter name="oracle-version" value="100"/>
<parameter name="oracle-port" value="1521"/>
<parameter name="oracle-dba-user" value="system"/>
<parameter name="oracle-dba-clear-password" value="dba"/>
<parameter name="oracle-connect-as" value="SYSDBA"/>
<parameter name="oracle-create-new-user" value="true"/>
<parameter name="oracle-i3-user" value="I3_OR_1234"/>
<parameter name="oracle-i3-clear-password" value="mypassword"/>
<parameter name="installation-cd-path" value="d:\"/>
</parameters>
The following table describes the updated elements of the parameter file. Element names marked with an asterisk (*) can be updated after installation.
Table 2-10 Elements of the Precise for Oracle parameter file
Element | Description |
---|---|
installation-cd-path | Indicates the absolute path to the folder where the Precise v9.6 download was downloaded to. Values: String Mandatory: Yes |
setup-process | Setup process. always apptier-OR Mandatory: Yes |
setup-mode* | Setup mode. Values: install, edit, uninstall Mandatory: Yes |
collector-server-machine-name | Name of the server on which the Precise for Oracle Collector will be installed. Values: String Mandatory: Yes |
environment-name | Name of the application. Values: String Mandatory: Yes, for a federation installation |
instance-name | Oracle instance name (SID). Values: String Mandatory: Yes |
oracle-home* | Full path of Oracle home. Values: String Mandatory: Yes |
oracle-version | Oracle instance version Values: 81, 90, 100, 110 The values represent the following versions: 81 = Version 8.1 Mandatory: Yes |
oracle-port* | Oracle instance Listener port. Values: Numeric Mandatory: Yes |
oracle-dba-user | User name for Oracle user with DBA privileges. Will only be used during installation. Values: String Mandatory: Yes |
oracle-dba-encrypted-password | Password for Oracle user with DBA privileges. Will only be used during installation. Values: Encrypted String Mandatory: Yes Alternatively the oracle-dba-clear-password can be used, allowing you to specify a clear password instead of an encrypted string. See Encrypt command on page 148. |
oracle-connect-as | Connection option for Oracle user with DBA privileges. When using a manual schema (see the "How to manually install Precise for Oracle database schemas" section in the Precise Installation Guide), this must be specified as Normal. Values: SYSDBA, Normal Mandatory: Yes |
network-ports | Oracle listener ports. Specify all the ports you want the Insight Savvy for Network to sample. At least one port must be specified. Values: port=x||port=y (for example: port=1111||port=2222) Mandatory: Yes if Install-network is ‘true’. |
oracle-create-new-user | Indicates whether the oracle-i3-user is an existing user or the installation should create a new user. Values: (true/false) Mandatory: Yes If an Oracle DB schema has been installed manually before the current collector installation, then this parameter should appear explicitly in the parameters file and its value must be "false". |
oracle-i3-user | User name of the Oracle user who owns the Precise for Oracle schema. Values: String Mandatory: Yes |
oracle-i3-encrypted-password | Password of the Oracle user who owns the Precise for Oracle schema. Values: Encrypted String See Encrypt command on page 148. Mandatory: Yes Alternatively the oracle-i3-clear-password can be used, allowing you to specify a clear password instead of an encrypted string. |
oracle-sap-system-name | The SAP system name. Values: String Mandatory: Yes, if install-sap-inter-point is true. |
oracle-sap-default-application-server | The Application server name used to create the first connection with the SAP system. Values: String Mandatory: Yes, if install-sap-inter-point is true. |
oracle-sap-system-number | The SAP system number. Values: String Mandatory: Yes, if install-sap-inter-point is true. |
oracle-sap-user | The SAP system user name. Values: String Mandatory: Yes, if install-sap-inter-point is true. |
oracle-sap-encrypted-password | The SAP system encrypted password. Values: Encrypted String Mandatory: Yes, if install-sap-inter-point is true. See Encrypt command on page 148. Alternatively the sap-clear-password can be used, allowing you to specify a clear password instead of an encrypted string. |
oracle-sap-client-id | The client ID used to create the first connection with the SAP system. Values: String Mandatory: Yes, if install-sap-inter-point is true. |
apptier-name | Name of the Tier. Values: String Mandatory: No |
install-alert-customized | Value: (true/false) Mandatory: No Set to true to in case you want to have customized alerts metrics for this instance. |
oracle-tablespace-name | Storage parameter for the Precise for Oracle schema. Indicates Tablespace name. Values: String Mandatory: No |
oracle-tablespace-file | Storage parameter for the Precise for Oracle schema. Indicates Tablespace datafile. Values: String Mandatory: No |
oracle-tablespace-temp-name | Storage parameter for the Precise for Oracle schema. Indicates Temporary tablespace name. Values: String Mandatory: No |
oracle-tablespace-temp-file | Storage parameter for the Precise for Oracle schema. Indicates Temporary tablespace file. Values: String Mandatory: No |
install-psoft-extension* | Installs the PeopleSoft extension Values: true, false Mandatory: No |
install-sap-inter-point | Indicates whether you want to install a SAP Interpoint. Values: true, false Mandatory: No |
oracle-history-size* | Oracle session information period (in hours). Values: 1, 2, 4, 8, 12, 24, 28 Mandatory: No |
oracle-collapse-statements* | Collapses statements with different constants in their text into single statements with bind variables. Values: true, false Mandatory: No |
install-storage-type* | Install Precise for Storage. Values: empty - for no Precise for Storage ORXP - for HP crosspoint storage Mandatory: No |
oracle-tablespaces-folder | Storage parameter for the Precise for Oracle schema. Indicates the folder in which datafiles are stored. Values: String Mandatory: No |
install-network* | Associates Oracle activity with network statistics. Values: true, false Mandatory: No |
oracle-cluster-name | Oracle instance cluster name Values: string Mandatory: No |
oracle-connection-pool-server | Server name used in the connection pool for the Oracle instance. In case this parameter is not supplied, the collector-server-machine-name is used. The Precise Oracle FocalPoint creates JDBC connections to the Oracle instance. Use this parameter in case you want the Oracle FocalPoint to connect to the instance using a server name different than the server name specified in collector-server-machine-name parameter. Value: String Mandatory: No |
Installing Precise for Storage with the Precise CLI utility
Installing Storage Tier Collectors on a server enables you to sample Storage instances on the server. Before installing Storage Tier Collector with the CLI utility, verify the following
- The Precise for Oracle FocalPoint or Precise for SQL Server FocalPoint is installed.
- The Precise Listener has been installed on the server where Precise for Storage agent is to be installed.
To install Precise for Storage with the Precise CLI utility
- Create the Precise for Storage parameter file and save it to the <precise_root> folder on the main Precise FocalPoint. You can also set up this file in advance. For more information, see About the Precise for Storage parameter file on page 32.
- Run the following command from the <precise_root> folder on the main Precise FocalPoint to execute the Precise CLI utility installation script.
Windows infra\bin\psin_cli.bat
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <precise_for_storage_installation_parameters_file_name>
UNIX ./infra/bin/psin_cli.sh
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <precise_for_storage_installation_parameters_file_name>
About the Precise for Storage parameter file
You need to prepare the Precise for Storage parameter file by creating an XML file with elements that represent the installation parameters and inserting the appropriate values.
The following is an example of a Precise for Storage parameters file:
<parameters>
<parameter name="setup-process" value="apptier-SM"/>
<parameter name="setup-mode" value="install"/>
<parameter name="collector-server-machine-name" value="sun3"/>
<parameter name="storage-type" value="EMC"/>
<parameter name="installation-cd-path" value="d:\"/>
</parameters>
The following table describes the updated elements of the parameter file.
Table 2-11 Elements of the Precise for Storage parameter file
Element | Description |
---|---|
installation-cd-path | Indicates the absolute path to the folder where the Precise v9.6 download was downloaded to. Values: String Mandatory: Yes |
setup-process | Setup process. always apptier-SM Mandatory: Yes |
setup-mode | Setup mode Values: install, edit, uninstall Mandatory: Yes |
collector-server-machine-name | Name of the server on which the Precise for Storage Collector will be installed. Values: String Mandatory: Yes |
environment-name | Name of the application. Values: String Mandatory: Yes, for a federation installation |
apptier-name | Name of the Tier. Values: String Mandatory: No |
emc-database-file | EMC Solution Enabler Database file location. Values: String Mandatory: No |
emc-gatekeeper-enabled | Enable remote gatekeeper. Values: true or false Mandatory: No |
emc-gatekeeper-ip | Remote gatekeeper server IP. Values: String Mandatory: Yes, if emc-gatekeeper-enabled is true. |
emc-gatekeeper-port | Remote gatekeeper server port. Values: Numeric Mandatory: Yes, if emc-gatekeeper-enabled is true. |
emc-asm-enabled | Enable Oracle ASM support for the EMC Storage agent. Values: true or false Mandatory: No |
emc-asm-instance | ASM instance name. Values: String Mandatory: Yes, if emc-asm-enabled is true. |
emc-asm-port | ASM instance port. Values: String Mandatory: Yes, if emc-asm-enabled is true. |
emc-asm-home | ASM instance home. Values: String Mandatory: No |
emc-asm-user | User name of an Oracle ASM user with DBA privileges. Values: String Mandatory: Yes, if emc-asm-enabled is true. |
emc-asm-encrypted-password | Password of an Oracle ASM user with DBA privileges. Values: Encrypted string Mandatory: Yes, if emc-asm-enabled is true. See Encrypt command on page 148. Alternatively the emc-clear-password can be used, allowing you to specify a clear password instead of an encrypted string. |
Installing Precise for J2EE with the Precise CLI utility
Installing J2EE Tier Collectors on a server enables you to sample a J2EE instance on the server. Before installing a J2EE Tier Collector with the Precise CLI utility, verify the following issues:
- The Precise Listener has been installed on the server where Precise for J2EE agent is to be installed. To install Precise for J2EE with the Precise CLI utility
- Create the Precise for J2EE parameter file and save it to the <precise_root> folder on the main Precise FocalPoint. You can also set up this file in advance. See About the Precise for J2EE parameter file on page 34.
- Run the following command from the <precise_root> folder on the main Precise FocalPoint to execute the Precise CLI utility installation script.
Windows infra\bin\psin_cli.bat
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <precise_for_j2ee_installation_parameters_file_name>
UNIX ./infra/bin/psin_cli.sh
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <precise_for_j2ee_installation_parameters_file_name>
About the Precise for J2EE parameter file
You need to prepare the Precise for J2EE parameter file by creating an XML file with elements that represent the installation parameters and inserting the appropriate values.
The following is an example of a Precise for J2EE parameters file:
<parameters>
<parameter name="setup-process" value="apptier-JE"/>
<parameter name="setup-mode" value="install"/>
<parameter name="instance-identifier" value="J2EE-Application"/>
<parameter name="collector-server-machine-name" value="sun3"/>
<parameter name="j2ee-type" value="JES"/>
<parameter name="j2ee-version" value="3"/>
<parameter name="j2ee-java-home" value="" />
<parameter name="is-cluster" value="false"/>
<parameter name="installation-cd-path" value="d:\"/>
</parameters>
The following table describes the updated elements of the parameter file.
Table 2-12 Elements of the Precise for J2EE parameter file
Element | Description |
---|---|
installation-cd-path | Indicates the absolute path to the folder where the Precise v9.6 download was downloaded to. Values: String Mandatory: Yes |
setup-process | Setup process. always apptier-JE Mandatory: Yes |
setup-mode | Setup mode Values: install, edit, uninstall Mandatory: Yes |
collector-server-machine-name | Name of the server on which the Precise for J2EE Collector will be installed. Values: String Mandatory: Yes |
instance-name | J2EE instance name. Values: String Mandatory: No. This parameter is only relevant when the setup-mode is uninstall. |
instance-identifier | Used to create the instance name. Values: String Mandatory: Yes |
is-cluster | Indicates that this instance is part of a cluster. Values: (true/false). Mandatory: Yes |
show-historical-data | Indicates if historical data from the deleted instance is shown (true) or deleted (false) Values: true/false Mandatory: No. This parameter is only relevant when the setup-mode is uninstall. |
j2ee-type | J2EE application server type. Values: WebLogic, WebSphere, JBoss, JEUS, JES, JRun, Tomcat, Resin, Oracle, SAP, Other Mandatory: Yes |
j2ee-version | J2EE application server version. Values: For WebLogic: 7.0, 8.1, 8.1 (Portal), 9.0, 9.1, 9.2, 9.2 (Portal), 10.0, 10.0 (Portal), 10.3, 10.3(Portal) For WebSphere: 5.0, 5.1, 5.1 (Portal), 6.0, 6.1 For JBoss: 3.2, 4.0 For JEUS: 4.2, 5.0 For JES: 2, 3 For JRun: 4.x For Tomcat: 4.x, 5.0, 5.5 For Resin: 2.1, 3.x For Oracle 9i AS: 1.0.2.2.2 (Release 1) 9.0.2.x (OC4Jstandalone) 9.0.2.x (Enterprise Edition) 9.0.3.0.0 (OC4J standalone) 9.0.3.0.0 (Enterprise Edition) 9.0.4 11.5.8 (Oracle Applications-Forms Listener Servlet Mode) 10.1.2 10.1.3 For Other: Other For SAP: 6.4 Mandatory: Yes |
j2ee-java-home | J2EE application server java home. Value: String Mandatory: Yes (can be empty) |
apptier-name | Name of the Tier. Values: String Mandatory: No |
install-alert-customized | Values: true/false Mandatory: No Set to true in case you want to have customized alerts metrics for this instance. |
environment-name | Name of the application. Values: String Mandatory: Yes, for a federation installation |
install-network* | Associates J2EE activity with network statistics. Values: true, false Mandatory: No |
network-ports | Network ports used by the J2EE instance, specify at least one port. Values: port=x||port=y (for example: port=1111||port=2222) Mandatory: Yes if install-network is set to true. |
j2ee-weblogic-started-by-node-manager | Indicates whether this is a managed WebLogic. Values: true/false Mandatory: Yes, if j2ee-type is WebLogic. |
Installing Precise for Web with the Precise CLI utility
Installing Web Tier Collectors on a server enables you to sample a Web instance on the server. Before installing a Web Tier Collector with the Precise CLI utility, verify the following issues:
- The Precise for Web FocalPoint is installed and running.
- The Precise Listener on the target server on which the Precise for Web agent is to be installed, was installed. To install Precise for Web with the Precise CLI utility
- Create the Precise for Web parameter file and save it to the <precise_root> folder on the main Precise FocalPoint. You can also set up this file in advance. See About the Precise for Web parameter file (Precise CLI utility) on page 37.
- Run the following command from the <precise_root> folder on the main Precise FocalPoint to execute the Precise CLI utility installation script. Use the Precise user that was created when the Precise server was defined.
Windows infra\bin\psin_cli.bat
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <precise_for_web_installation_parameters_file_name>
UNIX ./infra/bin/psin_cli.sh
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <precise_for_web_installation_parameters_file_name>
About the Precise for Web parameter file (Precise CLI utility)
You need to prepare the Precise for Web parameter file by creating an XML file with elements that represent the installation parameters and inserting the appropriate values.
Example:
<parameters>
<parameter name="setup-process" value="apptier-WW"/>
<parameter name="collector-server-machine-name" value="server1"/>
<parameter name="web-type" value="IIS"/>
<parameter name="instance-identifier" value="WEB1" />
<parameter name="is-cluster" value="false" />
<parameter name="web-real-name" value="Default Web Site" />
<parameter name="web-server-version" value="6.x" />
<parameter name="web-application-used" value="Web" />
<parameter name="install-filters" value="true" />
<parameter name="install-instrumentation" value="true" />
<parameter name="install-dynamic-instrumentation" value="true" />
<parameter name="web-collect-extended-information" value="false" />
<parameter name="web-ports" value="port=80;ip=server1;ssl=true"/>
<parameter name="web-iis-instance-number" value="1"/>
<parameter name="installation-cd-path" value="d:\"/>
</parameters>
Table 2-13 Elements of the Precise for Web parameter file
Element | Description |
---|---|
installation-cd-path | Indicates the absolute path to the folder where the Precise v9.6 download was downloaded to. Values: String Mandatory: Yes |
setup-process | Setup process. always apptier-WW Mandatory: Yes |
setup-mode | Setup Mode Values: install, edit, uninstall Mandatory: Yes |
collector-server-machine-name | Name of the server of the Collector. Values: String Mandatory: Yes |
instance-name | The unique name of the Web server instance as identified on the Web server. This unique name helps to distinguish between several instances. Values: String Mandatory: No. This parameter is only relevant when the setup-mode is uninstall. |
instance-identifier | Used to create the instance name. Values: String Mandatory: Yes |
is-cluster | Indicates that this instance is part of a cluster. Values: (true/false). Can only be set to true for WebLogic and WebSphere. Mandatory: Yes |
show-historical-data | Indicates if historical data from the deleted instance is shown (true) or deleted (false) Values: true/false Mandatory: No. This parameter is only relevant when the setup-mode is uninstall. |
web-type | Indicates type of server where the Web server instance is running. Values: IIS, Apache, iPlanet, WebLogic, WebSphere, Tomcat, Sun ONE, SAP WAS J2EE, Oracle AS, Other J2EE, Other. Mandatory: Yes |
web-configuration-file | The full path for a Web server configuration file. Values: String Mandatory: Yes for Web Servers - Apache, iPlanet, WebLogic, Sun ONE, WebSphere, Tomcat, Oracle AS. Mandatory: Web Servers - IIS, Other, Other J2EE, SAP WAS J2EE should all be specified as empty parameter. |
web-apache-configuration-file | The full path for an Apache HTTP Web server configuration file. Values: String Mandatory: Yes, only for Oracle AS servers. |
web-server-version | The Web server version. Values: String For IIS: Mandatory: Yes Versions: 5.x, 6.x For Other, Other J2EE, SAP WAS J2EE. Mandatory: No For Apache: Mandatory: Yes. Versions: 1.3.x, 2.0.x, 2.2.x For WebLogic: Mandatory: Yes. Versions: 8.x, 9.x, 10.x For WebSphere: Mandatory: Yes. Versions: 6.0, 6.1-6.x, 7.x For Tomcat: Mandatory: Yes. Versions: 5.x, 6.x For iPlanet: Mandatory: Yes Version: 6.x For Sun ONE: Mandatory: Yes Version: 6.1 For Oracle AS: Mandatory: Yes. Version: "9.0.4.0.1 - 10.1.3" (Notice the additional spaces) |
web-real-name | The IIS Web site name. Values: String Mandatory: Yes, only for IIS servers. |
web-iis-instance-number | The IIS Web site number. Values: String Mandatory: Yes, only for IIS servers. |
web-application-used | The application served by this Web server site. Values: Web Siebel PeopleSoft Mandatory: Yes |
web-application-used-version | The application version served by this Web server site. Values: String For PeopleSoft: Mandatory: Yes Values:
Values: Do not enter a value. For Siebel: Mandatory: Yes Values: "7.5 - 7.7" |
install-filters* | Indicates whether to install a filter on the Web server to collect server-side performance information. Values: true, false Mandatory: Yes Dependent on Web server type (some types do not support this, some force this installation). |
install-dynamic-instrumentation* | Indicates whether to perform dynamic instrumentation. Values: true, false Mandatory: Yes, only if "install-instrumentation" is true. Dependent on Web server type (some types do not support this, some force this installation). |
web-ports* | The ports to be used by the Web Tier Collectors. Use two pipelines "||" as a separator between the ports. Specify at least one port. Values: port=port number;ip=[ip value|ALL];host-header=host headers;ssl=[true|false] (for example: port=3333;ip=ALL;host-header=srv2;ssl=true||port=4444;ip=ALL;host-header=srv1;ssl=true). Mandatory: Yes, if install-network is true and is-cluster is false. |
web-server-bits | Web server bits. Values: 32, 64 Mandatory: Yes for Web Servers - Apache, iPlanet. |
web-server-root | The root of the Web site root. Mandatory: Yes, only for an Other Web server type. |
web-ssl-client-certification-path | Full path to the client certificate file. Values: String Mandatory: Yes if "web-ssl-use-client-certification" is true. |
web-server-i3-user-name | Web sever client name. Values: String Mandatory: Yes if "web-server-uses-authentication" is true. |
web-server-i3-password(encrypted) | Web server encrypted password. Values: String Mandatory: Yes if "web-server-uses-authentication" is true Alternatively the web-server-i3-clear-password can be used, allowing you to specify a clear password instead of an encrypted string. For more information, see Encrypt command on page 148. |
web-server-domain | Web server domain. Values: String Mandatory: Yes if "web-server-uses-authentication" is true. |
web-server-method | Web server method. Values: Basic, Digest, NTLM Mandatory: Yes if "web-server-uses-authentication" is true. |
web-ssl-client-certification-password (encrypted) | Encrypted password for the client certificate. Values: String Mandatory: No Alternatively the web-ssl-client-certification-clear-password can be used, allowing you to specify a clear password instead of an encrypted string. For more information, see Encrypt command on page 148. |
web-ssl-client-certification-key-path | Full path to the client certificate private key file Values: String Mandatory: No |
web-server-uses-authentication | Is the web server requires client authentication to establish a connection. Values: true\false Mandatory: No |
apptier-name | Name of the Tier for the added instance. Values: String Mandatory: No |
environment-name | Name of the application for the added instance. Values: String Mandatory: Yes, for a federation installation |
install-alert-customized | Value: true/false Mandatory: No Set to true to in case you want to have customized alerts metrics for this instance. |
web-site-name | Site name, sometimes called context root. Values: String Mandatory: No |
web-use-special-ssl-configuration | The only way to connect to the web server is using a secured connection (SSL). Values: true\false Mandatory: No |
web-special-ssl-ciphers | Cipher list. Values: Specify the ciphers to be used Comma separated. Mandatory: No |
web-ssl-use-client-certification | Specifies whether the web server requires the client certificate to have a certificate to establish a connection. Values: true\false Mandatory: No |
install-network | Indicates whether to correlate the data collected by the Web server filter with the data collected by the Insight Savvy for Network. Values: true, false Mandatory: No |
Installing Precise for Microsoft .NET with the Precise CLI utility
Installing Microsoft .NET Collectors on a server enables you to sample Microsoft .NET instances on the server. A Microsoft .NET Tier Collector can be installed only on servers running Microsoft .NET instances.
Before installing a Microsoft .NET Tier Collector with the Precise CLI utility, verify the following issues:
- The Precise Listener on the target server on which the Precise for Microsoft .NET agent is to be installed, was installed.
To install Precise for Microsoft .NET with the Precise CLI utility
- Create the Precise for Microsoft .NET parameter file and save it to the <precise_root> folder on the main Precise FocalPoint. For more information, see About the Precise for Microsoft .NET parameter file on page 42.
- Run the following command from the <precise_root> folder on the main Precise FocalPoint to execute the Precise CLI utility installation script. Use the Precise user that was created when the Precise server was defined.
Windows infra\bin\psin_cli.bat
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <precise_for_microsoft _.net_installation_parameters_file_name>
UNIX ./infra/bin/psin_cli.sh
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password>| -i3-clear-password <clear_password>}
-action setup
-parametersfile <precise_for_microsoft_.net_installation_parameters_file_name>
About the Precise for Microsoft .NET parameter file
You need to prepare the Precise for Microsoft .NET parameter file by creating an XML file with elements that represent the installation parameters and inserting the appropriate values.
The following table describes the updated elements of the Microsoft .NET parameter file. Parameters file example:
<root>
<parameter name="setup-process" value="apptier-DN"/>
<parameter name="collector-server-machine-name" value="serverwin1004"/>
<parameter name="instance-name" value="MyInstance"/>
<parameter name="type" value="web" />
<parameter name="application-name" value="IIS5" />
<parameter name="process-name" value="aspnet_wp.exe" />
<parameter name="installation-cd-path" value="d:\"/>
</root>
Table 2-14 Elements of the Precise for Microsoft .NET parameter file
Element | Description |
---|---|
installation-cd-path | Indicates the absolute path to the folder where the Precise v9.6 download was downloaded to. Values: String Mandatory: Yes |
setup-process | Setup process. always apptier-DN. Mandatory: Yes |
setup-mode | Setup mode. Values: install, edit, uninstall Mandatory: Yes |
collector-server-machine-name | Name of the server on which the Precise for Microsoft .NET Collector will be installed. Values: String Mandatory: Yes |
instance-name | The unique alphanumeric string used by Precise for Microsoft .NET and Insight to identify the monitored application instance. Values: String using English characters. Mandatory: Yes |
type | Indicates the type of the Microsoft .NET instance. Available types are as follows:
Mandatory: Yes |
application-name | If this instance is an ASP Microsoft .NET instance, the value for this field depends on the Internet Information Server (IIS) type: IIS5, or IIS6. For a regular Microsoft .NET instance the field should be left empty. Values: IIS5, IIS6, or empty Mandatory: Yes, for ASP Microsoft .NET instances. For all other instances, this must remain empty. |
process-name* | Indicates the name of the .NET process executable file. For a regular Microsoft .NET instance, the field should include the path and name of the Microsoft .NET executable file. For an ASP Microsoft .NET instance, the value for this field depends on the type of Internet Information Server (IIS) as follows:
process-name can only be updated after installation if the instance type is general. Values: String Mandatory: Yes |
apptier-name | Name of the Tier. Values: String Mandatory: No |
environment-name | Name of the application. Values: String Mandatory: Yes, for a federation installation. |
install-alert-customized | Values: true/false Mandatory: No Set to true to in case you want to have customized alerts metrics for this instance. |
application-pool | Specifies the application pool(s) to be monitored by this instance. Use "*" to specify multiple application pools for monitoring. Values: String Mandatory: No |
Installing Precise for SQL Server with the Precise CLI utility
Installing SQL Server Tier Collectors on a server enables you to sample SQL Server instances on the server. An SQL Server Tier Collector can be installed on Windows servers running SQL Server instances, or it can be installed on any Windows server and the SQL Server instances can be sampled remotely.
Before installing a SQL Server Tier Collector with the Precise CLI utility, verify the following issues:
- The Precise for SQL Server FocalPoint was installed.
- The Precise Listener on the target server on which the SQL Server Tier Collector is to be installed, was installed.
To install Precise for SQL Server with the Precise CLI utility
- Create the Precise for SQL Server parameter file and save it to the <precise_root> folder on the main Precise FocalPoint. You can also set up this file in advance. See About the Precise for SQL Server parameter file on page 44.
- Run the following command from the <precise_root> folder on the main Precise FocalPoint to execute the Precise CLI utility installation script. Use the Precise user that was created when the Precise server was defined.
Windows infra\bin\psin_cli.bat
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <precise_for_sql_server_installation_parameters_file_name>
UNIX ./infra/bin/psin_cli.sh
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password>| -i3-clear-password <clear_password>}
-action setup
-parametersfile <precise_for_sql_server_installation_parameters_file_name>
About the Precise for SQL Server parameter file
You need to prepare the Precise for SQL Server parameter file by creating an XML file with elements that represent the installation parameters and inserting the appropriate values in them.
The following is an example of a Sql Server instance parameters file:
<parameters>
<parameter name="installation-cd-path" value="d:\"/>
<parameter name="setup-process" value="apptier-SQ" />
<parameter name="setup-mode" value="install" />
<parameter name="collector-server-machine-name" value="server1" />
<parameter name="instance-name" value="SERVER1" />
<parameter name="sqlserver-authentication" value="sql" />
<parameter name="sqlserver-i3-user" value="sa" />
<parameter name="sqlserver-i3-clear-password" value="" />
</parameters>
The following table describes the updated elements of the parameter file. Field names marked with an asterisk (*) can be updated after installation.
Table 2-15 Elements of the Precise for SQL Server parameter file
Element | Description |
---|---|
installation-cd-path | Indicates the absolute path to the folder where the Precise v9.6 download was downloaded to. Values: String Mandatory: Yes |
setup-process | Setup process. always apptier-SQ Mandatory: Yes |
setup-mode | Setup mode. Values: install, edit, uninstall Mandatory: Yes |
instance-name | SQL Server instance name. (Must always be uppercase). Values: String Mandatory: Yes |
collector-server-machine-name | Name of the server on which the Precise for SQL Server Collector will be installed. Values: String Mandatory: Yes |
os-user | Specifies the Windows user that the SQL Server Collector should use. Values: String Mandatory: Only if the instance does not reside on the same server as the collector, or when the PMDB uses Windows authentication. |
os-domain | Specifies the Windows user’s domain that the SQL Server Collector should use. Values: String Mandatory: Only if the instance does not reside on the same server as the collector, or when the PMDB uses Windows authentication. |
os-encrypted-password | Specifies the Windows password that the SQL Server Collector should use. Values: Encrypted String. For more information, see Encrypt command on page 148. Mandatory: Only if the instance does not reside on the same server as the collector, or when the PMDB uses Windows authentication. Alternatively the os-clear-password parameter can be used, allowing you to specify a clear password instead of an encrypted string. |
sqlserver-authentication* | Specifies how the Collector will connect to the SQL Server instance. (Windows authentication/SQL authentication). Values: sql, nt Mandatory: Yes |
sqlserver-i3-user* | User name. Values: String Mandatory: Only mandatory if authentication is ‘sql’. |
sqlserver-i3-encrypted-password* | Password for SQL Server. Values: Encrypted String. Mandatory: Only mandatory if authentication is ‘sql’. For more information, see Encrypt command on page 148. Alternatively the sqlserver-i3-clear-password can be used, allowing you to specify a clear password instead of an encrypted string. |
install-storage-type* | Install Precise for Storage. Values: empty - for no Precise for Storage SQWIN - for Windows storage Mandatory: No |
install-psoft-extension* | Installs the PeopleSoft extension. Values: true, false Mandatory: No |
sqlserver-sap-system-name | The SAP system name. Values: String Mandatory: Yes, if install-sap-inter-point is true. |
sqlserver-sap-default-application-server | The Application server name used to create the first connection with the SAP system. Values: String Mandatory: Yes, if install-sap-inter-point is true. You can only specify one default-app-server and app-rout-string. |
sqlserver-sap-system-number | The SAP system number. Values: String Mandatory: Yes, if install-sap-inter-point is true. |
sqlserver-sap-user | The SAP system user name. Values: String Mandatory: Yes, if install-sap-inter-point is true. |
sqlserver-sap-encrypted-password | The SAP system encrypted password. Values: Encrypted String Mandatory: Yes, if install-sap-inter-point is true. For more information, see Encrypt command on page 148. Alternatively the sqlserver-sap-clear-password can be used, allowing you to specify a clear password instead of an encrypted string. |
sqlserver-sap-client-id | The client ID used to create the first connection with the SAP system. Values: String Mandatory: Yes, if install-sap-inter-point is true. |
install-sap-inter-point | Indicates whether you want to install SAP Interpoint Values: true, false Mandatory: No |
apptier-name | Name of the Tier. Values: String Mandatory: No |
environment-name | Name of the application. Values: String Mandatory: Yes, for a federation installation |
os-user | Specifies the Windows user that the collector should use. Values: String Mandatory: Must be specified if the PMBD uses Windows authentication. |
os-domain | Specifies the Windows user’s domain that the collector should use. Values: String Mandatory: Must be specified if the PMBD uses the Windows authentication. |
os-encrypted-password | Specifies the Windows password that the Collector should use. Values: Encrypted String. For more information, see Encrypt command on page 148. Alternatively the os-clear-password parameter can be used, allowing you to specify a clear password instead of an encrypted string. Mandatory: Must be specified if the PMBD uses Windows authentication. |
install-alert-customized | Values: true/false Mandatory: No Set to true to in case you want to have customized alerts metrics for this instance. |
Installing Precise for SAP with the Precise CLI utility
Installing SAP Collectors on a server enables you to sample a remote SAP system.
Before installing the SAP Tier Collector with the Precise CLI utility, verify the following issue:
- Precise for SAP FocalPoint was installed.
To install Precise for SAP with the Precise CLI utility
- Create the Precise for SAP parameter file and save it to the <precise_root> folder on the main Precise FocalPoint. You can also set up this file in advance. For more information, see About Precise for SAP parameter file on page 82.
- Run the following command from the <precise_root> folder on the main Precise FocalPoint to execute the Precise CLI utility installation script. Use the Precise user that was created when the Precise server was defined.
Windows infra\bin\psin_cli.bat
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <precise_for_sap_installation_parameters_file_name>
UNIX ./infra/bin/psin_cli.sh
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <precise_for_sap_installation_parameters_file_name>
About Precise for SAP parameter file
You need to prepare the Precise for SAP parameter file by creating an XML file with elements that represent the installation parameters and inserting the appropriate values.
The following table describes the updated elements of the parameter file. Element names marked with an asterisk (*), in this table, can be updated after installation.
Example:
<parameters>
<parameter name="setup-process" value="apptier-SP"/>
<parameter name="setup-mode" value="install"/>
<parameter name="instance-name" value="H47_TEST2" />
<parameter name="sap-system" value="H47" />
<parameter name="default-app-server" value="poolhp3" />
<parameter name="app-server-exist" value="true" />
<parameter name="app-rout-string-exist" value="false" />
<parameter name="app-rout-string" value="" />
<parameter name="db-system-number" value="00" />
<parameter name="sap-user" value="adm" />
<parameter name="sap-clear-password" value="precise" />
<parameter name="client-id" value="000" />
<parameter name="environment-name" value="Default" />
<parameter name="app-servers" value="host=poolhp3;routing-str=;port=00;name=poolhp3_H47_00" />
<parameter name="clients" value="lang=E;number=000||lang=E;number=001||lang=E;number=066||lang=E;number=100" />
<parameter name="installation-cd-path" value="d:\"/>
</parameters>
Table 2-16 Elements of the Precise for SAP parameter file
Element | Description |
---|---|
installation-cd-path | Indicates the absolute path to the folder where the Precise v9.6 download was downloaded to. Values: String Mandatory: Yes |
setup-process | Setup process. always apptier-SP Mandatory: Yes |
setup-mode | Setup mode. Values: install, edit, uninstall Mandatory: Yes |
instance-name | The unique name for the instance. This unique name helps to distinguish between several instances. Values: String Mandatory: Yes |
sap-clients | The SAP clients numbers and language that the SAP Collector should monitor. Use two pipelines "||" as a separator between the clients names. lang=E;number=000||lang=E;number=001||lang=E;number=066||lang=E;number=100 Value: String Mandatory: No If not specified, all clients detected will be monitored. |
sap-system | The SAP system name. Values: String Mandatory: Yes |
default-app-server* | The Application server name used to create the first connection with the SAP system. Values: String Mandatory: Yes, if app-rout-string is not provided. |
app-rout-string* | The Application server route string used to create the first connection with the SAP system. Values: String Mandatory: Yes, if default-app-server is not provided. |
sap-connection-type | The connection type to use when connecting to SAP Values: String (CustomApplicationServer/LogonGroup) Mandatory: No Default value: CustomApplicationServer |
sap-logon-group | Group/Server to use when connecting to SAP Values : String Mandatory: Yes, if sap-connection-type is LogonGroup |
db-system-number* | The SAP system number. Values: String Mandatory: Yes |
sap-user* | The SAP system user name. Values: String Mandatory: Yes |
sap-encrypted-password* | The SAP system encrypted password. Values: Encrypted String Mandatory: Yes. For more information, see Encrypt command on page 148. Alternatively the sap-clear-password can be used, allowing you to specify a clear password instead of an encrypted string. |
client-id* | The client ID used to create the first connection with the SAP system. Values: String Mandatory: Yes |
app-servers* | The Application servers that the SAP Collectors should monitor. Use two pipelines "||" as a separator between the Application server names. Format: name=application-server-name;host=host-name; routing-str=routing-string;port=port-number Values: String Mandatory: No If not specified, all application servers detected will be monitored. |
apptier-name | Name of the Tier. Values: String Mandatory: No |
environment-name | Name of an existing application. Values: String Mandatory: Yes |
Installing Precise for Sybase with the Precise CLI utility
Installing the Sybase Tier Collector on a server enables you to sample a Sybase instance on the server. A Sybase Tier Collector can be installed on Windows servers running Sybase instances, or it can be installed on any Windows server and sample the Sybase instance remotely.
Before installing the Sybase Tier Collector with the Precise CLI utility, verify the following issues:
- Precise for Sybase FocalPoint was installed.
- The Precise Listener was installed on the target server on which the Sybase Tier Collector is to be installed.
- The Precise Listener and all FocalPoints installed on the target server are running and accessible on the network. To install Precise for Sybase with the Precise CLI utility
- Create the Precise for Sybase parameter file and save it to the <precise_root> folder on the main Precise FocalPoint. You can also create this file in advance. See About the Precise for Sybase parameter file on page 84.
- Run the following command from the Precise root folder on the main Precise FocalPoint. This executes the Precise CLI utility installation script.
Windows infra\bin\psin_cli.bat
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <precise_for_sybase_installation_parameters_file_name>
UNIX ./infra/bin/psin_cli.sh
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password>| -i3-clear-password <clear_password>}
-action setup
-parametersfile <precise_for_sybase_installation_parameters_file_name>
About the Precise for Sybase parameter file
When you install Precise for Sybase with the Precise CLI utility, you must first create an XML file that contains all relevant installation parameters and their respective values. This file is referenced by the Precise CLI utility installation script during the installation process.
The following is an example of an Precise for Sybase parameters file:
<parameters>
<parameter name="setup-process" value="apptier-SY"/>
<parameter name="setup-mode" value="install"/>
<parameter name="apptier-name" value="Sybase"/>
<parameter name="environment-name" value="Default"/>
<parameter name="collector-server-machine-name" value="pifa102"/>
<parameter name="instance-server-machine-name" value="sun12"/>
<parameter name="sybase-instance-name" value="sun12_12_0"/>
<parameter name="sybase-port" value="5100"/>
<parameter name="sybase-i3-user" value="sa"/>
<parameter name="sybase-i3-encrypted-password" value="IE"/>
<parameter name="installation-cd-path" value="d:\"/>
</parameters>
The identity of a Sybase instance is determined by a concatenation of the instance-server-machine-name tag and the sybase-instance-name tag.
The following table describes the updated elements of the parameter file. Field names marked with an asterisk (*) can be updated after installation.
Table 2-17 Elements of the Precise for Sybase parameter file
Element | Description |
---|---|
installation-cd-path | Indicates the absolute path to the folder where the Precise v9.6 download was downloaded to. Values: String Mandatory: Yes |
setup-process | Setup process. always apptier-SY Mandatory: Yes |
setup-mode | Setup mode. Values: install, edit, uninstall Mandatory: Yes |
instance-server-machine-name | Name of the server that the Sybase instance is installed on. Values: String Mandatory: Yes |
sybase-instance-name | Name of the Sybase instance. Values: String Mandatory: Yes |
collector-server-machine-name | Name of the server on which the Precise for Sybase Collector will be installed. Values: String Mandatory: Yes |
sybase-port* | The number of the port that the Sybase instance is listening on. Values: Integer Mandatory: Yes |
sybase-i3-user | The name of the user. Values: String Mandatory: Yes |
sybase-i3-encrypted-password | The password for the user name. Values: Encrypted String. Mandatory: Yes. For more information, see Encrypt command on page 148. Alternatively the sybase-i3-clear-password can be used, allowing you to specify a clear password instead of an encrypted string. |
apptier-name | Name of the Tier. Values: String Mandatory: No |
environment-name | Name of the application. Values: String Mandatory: Yes, for a federation installation |
install-alert-customized | Values: true/false Mandatory: No Set to true to in case you want to have customized alerts metrics for this instance. |
Installing Precise for Sybase Replication Server with the Precise CLI utility
Installing the Sybase Replication Server Tier Collector on a server, enables you to sample a Sybase Replication Server instance on the server.
Sybase Replication Server Tier Collector can be installed on Windows servers running Sybase Replication Server instances, or it can be installed on any Windows server and sample the Sybase Replication Server instance remotely.
Before installing the Sybase Replication Server Tier Collector with the Precise CLI utility, verify the following issues:
- Precise for Sybase FocalPoint was installed.
- The Precise Listener was installed on the target server on which the Sybase Replication Server Tier Collector is to be installed.
- The Precise Listener and all FocalPoints installed on the target server are running and accessible on the network. To install Precise for Sybase Replication Server with the Precise CLI utility
- Create the Precise for Sybase Replication Server parameter file and save it to the <precise_root> folder on the main Precise FocalPoint. You can also create this file in advance. For more information, see About the Precise for Sybase Replication Server parameter file on page 86.
- With the user that you created when defining the Precise server, run the following command from the <precise_root> folder on the main Precise FocalPoint. This executes the Precise CLI utility installation script.
Windows infra\bin\psin_cli.bat
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <name_of_the_sybase_replication_server_parameters_file>
UNIX ./infra/bin/psin_cli.sh
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <name_of_the_sybase_replication_server_parameters_file>
About the Precise for Sybase Replication Server parameter file
When you install Precise for Sybase Replication Server with the Precise CLI utility, you must first create an XML file that contains all relevant installation parameters and their respective values. This file is referenced by the Precise CLI utility installation script during the installation process.
The following is an example of a Precise for Sybase Replication Server parameters file:
<root>
<parameter name="setup-process" value="apptier-RS"/>
<parameter name="sybase-replication-server-instance-name" value="POOLSUN1_1501_REP"/>
<parameter name="instance-server-machine-name" value="poolsun1"/>
<parameter name="collector-server-machine-name" value="pifa100"/>
<parameter name="sybase-replication-server-port" value="5006"/>
<parameter name="sybase-replication-server-i3-user" value="sa"/>
<parameter name="sybase-replication-server-i3-encrypted-password" value="IE"/>
<parameter name="sybase-replication-server-sql-ini-path" value="C:\\sybase\\ini\\sql.ini"/>
<parameter name="sybase-replication-server-rssd-instance" value="I4SQLV65_1502"/>
<parameter name="sybase-replication-server-rssd-database" value="POOLSUN1_1501_REP_RSSD"/>
<parameter name="sybase-replication-server-rssd-host" value="i4sqlv65"/>
<parameter name="sybase-replication-server-rssd-port" value="5001"/>
<parameter name="sybase-replication-server-rssd-i3-user" value="sa"/>
<parameter name="sybase-replication-server-rssd-encrypted-password" value="IE"/>
<parameter name="installation-cd-path" value="d:\"/>
</root>
The identity of a Sybase Replication Server instance is determined by a concatenation of the instance-server-machine-name tag and the sybase-replication-server-instance-name tag.
The following table describes the updated elements of the parameter file. Field names marked with an asterisk (*) can be updated after installation.
Table 2-18 Elements of the Sybase Replication Server parameter file
Element | Description |
---|---|
collector-server-machine-name | Name of the server on which the Sybase Replication Server Collector will be installed. Values: String Mandatory: Yes |
instance-server-machine-name | Name of the server that the Sybase Replication Server instance is installed on. Values: String Mandatory: Yes |
setup-mode | Values: install, edit, uninstall Mandatory: Yes |
setup-process | always apptier-RS Mandatory: Yes |
installation-cd-path | Indicates the absolute path to the folder where the Precise v9.6 download was downloaded to. Values: String Mandatory: Yes |
sybase-replication-server-instance-name | Name of the Sybase Replication Server instance. Values: String Mandatory: Yes |
sybase-replication-server-port* | The number of the port that the Sybase Replication Server instance is listening on. Values: Integer Mandatory: Yes |
sybase-replication-server-i3-user | The name of the user. Values: String Mandatory: Yes |
sybase-replication-server-i3-encrypted-password | The password for the user name. Values: Encrypted String. Mandatory: Yes. For more information, see Encrypt command on page 148. Alternatively the sybase-replication-server-i3-clear-password can be used, allowing you to specify a clear password instead of an encrypted string. |
sybase-replication-server-sql-ini-path | The path to Sybase Replication Server instance sql.ini file Values: String Mandatory: Yes |
sybase-replication-server-rssd-instance | Name of the Sybase Replication Server ASE instance. Values: String Mandatory: Yes |
sybase-replication-server-rssd-database | Name of the Sybase Replication Server ASE database. Values:String Mandatory: Yes |
sybase-replication-server-rssd-host | Name of the Sybase Replication Server ASE host Values: String Mandatory: Yes |
sybase-replication-server-rssd-port* | Port of the Sybase Replication Server ASE Values: Integer Mandatory: Yes |
sybase-replication-server-rssd-i3-user | The name of the Sybase Replication Server ASE user Values: String Mandatory: Yes |
sybase-replication-server-rssd-encrypted-password | The password of the user of Sybase Replication Server ASE Values: Encrypted String. Mandatory: Yes. For more information, see Encrypt command on page 148. Alternatively the sybase-replication-server-rssd-clear-password can be used, allowing you to specify a clear password instead of an encrypted string. |
apptier-name | Name of the Tier. Values: String Mandatory: No |
environment-name | Name of the application. Values: String Mandatory: Yes, for a federation installation |
install-alert-customized | Values: true/false Mandatory: No Set to true to in case you want to have customized alerts metrics for this instance. |
os-user | Specifies the Windows user that the collector should use. Values: String Mandatory: Must be specified if the PMBD uses Windows authentication. |
os-domain | Specifies the Windows user’s domain that the collector should use. Values: String Mandatory: Must be specified if the PMBD uses the Windows authentication. |
os-encrypted-password | Specifies the Windows password that the Collector should use. Values: Encrypted String. For more information, see Encrypt command on page 148. Alternatively the os-clear-password parameter can be used, allowing you to specify a clear password instead of an encrypted string. Mandatory: Must be specified if the PMBD uses Windows authentication. |
Installing Precise for DB2 with the Precise CLI utility
Installing DB2 Tier Collectors on a server enables you to monitor DB2 instances on the server. A DB2 Tier Collector should be installed for each DB2 instance on the server that will be monitored. Before installing a DB2 Tier Collector with the Precise CLI utility, verify the following issues:
- The Precise for DB2 FocalPoint was installed.
- The Listener on the target server on which the Precise for DB2 agent is to be installed was installed. To install Precise for DB2 with the Precise CLI utility
- Create the Precise for DB2 parameter file and save it to the <precise_root> folder on the main Precise FocalPoint. You can also set up this file in advance. For more information, see About the Precise for DB2 parameter file on page 84.
- Run the following command from the <precise_root> folder on the main Precise FocalPoint to execute the Precise CLI installation script:
Windows infra\bin\psin_cli.bat
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <precise_for_db2_installation_parameters_file_name>
UNIX ./infra/bin/psin_cli.sh
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <precise_for_db2_installation_parameters_file_name>
About the Precise for DB2 parameter file
You need to prepare the Precise for DB2 parameter file by creating an XML file with elements that represent the installation parameters and inserting the appropriate values.
The following is an example of a Precise for DB2 parameters file:
<parameters>
<parameter name="setup-process" value="apptier-UD"/>
<parameter name="setup-mode" value="install"/>
<parameter name="collector-server-machine-name" value="sun3"/>
<parameter name="db2-instance" value="db2inst1" />
<parameter name="db2-database" value="SAMPLE" />
<parameter name="db2-user" value="db2inst1" />
<parameter name="db2-clear-password" value="db2inst1" />
<parameter name="db2-port" value="60000" />
<parameter name="db2-partition" value="0" />
<parameter name="db2-tablespace" value="APM_DB2" />
<parameter name="db2-tablespace-container" value="APM_DB2" />
<parameter name="installation-cd-path" value="d:\"/>
</parameters>
The following table describes the elements of the Precise for DB2 parameter file. Element names marked with an asterisk (*) can be updated after installation.
Table 2-19 Elements of the Precise for DB2 parameter file
Element | Description |
---|---|
installation-cd-path | Indicates the absolute path to the folder where the Precise v9.6 download was downloaded to. Values: String Mandatory: Yes |
setup-process | Setup process. Values: apptier-UD Mandatory: Yes |
setup-mode | Setup mode. Values: install, edit, uninstall Mandatory: Yes |
collector-server-machine-name | Name of the server on which the Precise for DB2 Collector will be installed. Values: String Mandatory: Yes |
environment-name | Name of the application. Values: String Mandatory: Yes, for a federation installation. |
db2-instance | DB2 instance name. Values: String Mandatory: Yes |
db2-database | DB2 database name. Values: String Mandatory: Yes |
db2-partition | DB2 partition number. Values: Numeric Mandatory: Yes |
db2-dba-user | User name for DB2 user with DBA privileges. Will only be used during installation. Values: String Mandatory: Yes |
db2-encrypted-password | Password for DB2 user with DBA privileges. Will only be used during installation. Values: Encrypted String Mandatory: Yes. For more information, see Encrypt command on page 148. Alternatively the db2-clear-password can be used, allowing you to specify a clear password instead of an encrypted string. |
db2-port* | DB2 instance Listener port. Values: Numeric Mandatory: Yes |
db2-tablespace | Storage parameter for the Precise for DB2 schema. Indicates Tablespace name. Values: String Mandatory: Yes |
db2-tablespace-container | Tablespace container. Values: String Mandatory: Yes |
install-storage | Install Precise for Storage for Precise file systems and logical volumes. Values: true, false Mandatory: No, default is false. |
symmetric-api-path | EMC path. Value: String Mandatory:Yes if install storage is true |
install-sap-inter-point | Indicates whether you want to install sap interpoint. Values: true, false Mandatory: No |
db2-sap-system-name | The SAP system name. Values: String Mandatory: Yes, if install-sap-inter-point is true. |
db2-sap-default-application-server | The Application server name used to create the first connection with the SAP system. Values: String Mandatory: Yes, if install-sap-inter-point is true. |
db2-sap-system-number | The SAP system number. Values: String Mandatory: Yes, if install-sap-inter-point is true. |
db2-sap-user | The SAP system user name. Values: String Mandatory: Yes, if install-sap-inter-point is true. |
db2-sap-encrypted-password | The SAP system encrypted password. Values: Encrypted String Mandatory: Yes, if install-sap-inter-point is true. For more information, see Encrypt command on page 148. Alternatively the db2-sap-clear-password can be used, allowing you to specify a clear password instead of an encrypted string. |
db2-sap-client-id | The client ID used to create the first connection with the SAP system. Values: String Mandatory: Yes, if install-sap-inter-point is true. |
apptier-name | Name of the Tier. Values: String Mandatory: No |
install-alert-customized | Value: true/false Mandatory: No Set to true to in case you want to have customized alerts metrics for this instance. |
Installing a Tuxedo instance with the Precise CLI utility
Installing Tuxedo Collectors on a server enables you to sample Tuxedo instances on the server. A Tuxedo Tier Collector can be installed only on servers running Tuxedo instances.
Before installing a Tuxedo Tier Collector with the Precise CLI utility, verify the following issues:
- The Insight FocalPoint is installed.
- The Precise Listener on the target server on which the Tuxedo Collector is to be installed, was installed. To install Tuxedo instance with the Precise CLI utility
- Create the Tuxedo instance parameter file and save it to the <precise_root> folder on the main Precise FocalPoint. You can also set up this file in advance. For more information, see About Tuxedo Collector parameter file on page 84.
- Run the following command from the <precise_root> folder on the main Precise FocalPoint to execute the Precise CLI utility installation script. Use the Precise user that was created when the Precise server was defined.
Windows infra\bin\psin_cli.bat
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <insight_savvy_for_tuxedo_ installation_parameters_file_name>
UNIX ./infra/bin/psin_cli.sh
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <insight_savvy_for_tuxedo_ installation_parameters_file_name>
About Tuxedo Collector parameter file
You need to prepare the Insight Savvy for Tuxedo parameter file by creating an XML file with elements that represent the installation parameters and inserting the appropriate values.
The following is an example of a Tuxedo instance parameters file:
<parameters>
<parameter name="setup-process" value="apptier-TU"/>
<parameter name="setup-mode" value="install"/>
<parameter name="apptier-name" value="Tuxedo"/>
<parameter name="environment-name" value="Default"/>
<parameter name="collector-server-machine-name" value="pifa102"/>
<parameter name="tuxedo-domain" value="tux_aix1"/>
<parameter name="instance-name" value="myInstance"/>
<parameter name="tuxedo-directory" value="/Oracle2/Tuxedo/65"/>
<parameter name="tuxedo-config-file" value="/Oracle2/Tuxedo/65/apps/ simapp/tuxconfig"/>
<parameter name="tuxedo-version" value="65"/>
<parameter name="install-network" value="true"/>
<parameter name="installation-cd-path" value="d:\"/>
</parameters>
The following table describes the updated elements of the parameter file. Element names marked with an asterisk (*) in this table can be updated after installation.
Table 2-20 Elements of the Tuxedo Collector parameter file
Element | Description |
---|---|
installation-cd-path | Indicates the absolute path to the folder where the Precise v9.6 download was downloaded to. Values: String Mandatory: Yes |
setup-process | Setup process. Always apptier-TU Mandatory: Yes |
setup-mode | Setup mode. Values: install, edit, uninstall Mandatory: Yes |
collector-server-machine-name | Name of the server on which the Tuxedo Collector will be installed. Values: String Mandatory: Yes |
instance-name (component identifier field) | Name of the Tuxedo instance that will be installed. Values: String Mandatory: Yes |
show-historical-data | Indicates if historical data from the deleted instance is shown (true) or deleted (false) Values: true/false Mandatory: No. This parameter is only relevant when the setup-mode is uninstall. |
tuxedo-domain | Name of the Tuxedo domain where the Tuxedo Tier will be installed. Values: String Mandatory: Yes |
tuxedo-directory* | The installation home folder for the Tuxedo information system. Values: String Mandatory: Yes |
tuxedo-config-file* | The full binary path of the configuration file for the Tuxedo information system that is planned to be monitored. Values: String Mandatory: Yes |
tuxedo-version* | The BEA Tuxedo version. Precise supports BEA Tuxedo 6.4 to 9.0. Values: String (XY[_64]). XY are the two digits for the version number. Add "_64" for 64-bits domains. For example: for BEA Tuxedo version 7.1 32-bits use "71"; for 9.0 64-bits use "90_64" Mandatory: Yes |
install-network* | Associates a Tuxedo activity with network statistics. Values: true, false Mandatory: No |
apptier-name | Name of the Tier. Values: String Mandatory: No |
environment-name | Name of the application. Values: String Mandatory: Yes, for a federation installation |
install-alert-customized | Values: true/false Mandatory: No Set to true to in case you want to have customized alerts metrics for this instance. |
Installing a WebSphere MQ instance with the Precise CLI utility
Installing WebSphere MQ Collectors on a server enables you to sample WebSphere MQ instances on the server. A WebSphere MQ Tier Collector can be installed only on servers running WebSphere MQ instances.
Before installing a WebSphere MQ Tier Collector with the Precise CLI utility, verify the following issues:
- The Insight FocalPoint is installed.
- The Precise Listener on the target server on which the WebSphere MQ Tier Collector is to be installed, was installed.
To install the WebSphere MQ instance with the Precise CLI utility
- Create the WebSphere MQ instance parameter file and save it to the <precise_root> folder on the main Precise FocalPoint. You can also set up this file in advance. For more information, see About WebSphere MQ instance parameter file on page 83.
- Run the following command from the <precise_root> folder on the main Precise FocalPoint to execute the Precise CLI utility installation script. Use the Precise user that was created when the Precise server was defined.
Windows infra\bin\psin_cli.bat
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <insight_savvy_for_websphere_mq_ installation_parameters_file_name>
UNIX ./infra/bin/psin_cli.sh
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <insight_savvy_for_websphere_mq_ installation_parameters_file_name>
About WebSphere MQ instance parameter file
You need to prepare the WebSphere MQ instance parameter file by creating an XML file with elements that represent the installation parameters and inserting the appropriate values.
The following is an example of a WebSphere MQ instance parameters file:
<parameters>
<parameter name="setup-process" value="apptier-MQ" />
<parameter name="instance-name" value="mqTest" />
<parameter name="collector-server-machine-name" value="server1" />
<parameter name="mq-queue-manager-name" value="mqTest" />
<parameter name="mq-home-directory" value="D:\Program Files\IBM\WebSphere MQ" />
<parameter name="mq-library" value="D:\Program Files\IBM\WebSphere MQ\Exits" />
<parameter name="installation-cd-path" value="d:\"/>
</parameters>
The following table describes the updated elements of the parameter file. Element names marked with an asterisk (*), in this table, can be updated after installation.
Table 2-21 Elements of the WebSphere MQ instance parameter file
Element | Description |
---|---|
installation-cd-path | Indicates the absolute path to the folder where the Precise v9.6 download was downloaded to. Values: String Mandatory: Yes |
setup-process | Setup process. Always apptier-MQ Mandatory: Yes |
setup-mode | Setup mode. Values: install, edit, uninstall Mandatory: Yes |
collector-server-machine-name | Name of the server the MQ Tier will be installed on. Values: String Mandatory: Yes |
show-historical-data | Indicates if historical data from the deleted instance is shown (true) or deleted (false) Values: true/false Mandatory: No. This parameter is only relevant when the setup-mode is uninstall. |
instance-name | A unique name of the WebSphere MQ instance. This unique name helps to distinguish between several instances. Use the name of the corresponding Queue Manager. Values: String Mandatory: Yes |
mq-queue-manager-name | The Queue Manager that the WebSphere MQ Tier Collector will sample. Values: String Mandatory: Yes |
mq-home-directory* | The full folder path of the WebSphere MQ software component configuration, to be used with this instance. Values: String Mandatory: Yes |
mq-library* | The full folder path of the library where WebSphere MQ software components keep the API exits. Values: String Mandatory: Yes |
install-network* | Associates WebSphere MQ activity with network statistics. Values: true, false Mandatory: No, default is false |
network-ports* | WebSphere MQ listener ports. Use two pipelines "||" as a separator between the ports. Specify all the ports you want the Insight Savvy for Network to sample. At least one port must be specified. Values: port=x||port=y (for example: port=1111||port=2222) Mandatory: Yes if |
apptier-name | Name of the Tier. Values: String Mandatory: No |
environment-name | Name of the application. Values: String Mandatory: Yes, for a federation installation |
install-alert-customized | Values: true/false Mandatory: No Set to true to in case you want to have customized alerts metrics for this instance. |
Installing an Oracle Applications instance with the Precise CLI utility
Installing Oracle Applications Collectors on a server enables you to sample Oracle Applications instances on the server.
Before installing an Oracle Applications Tier Collector with the Precise CLI utility, verify the following issues:
- The Precise for Oracle FocalPoint and Precise for Oracle Collector are installed and running.
- The Precise Listener on the target server on which the Oracle Applications Tier Collector is to be installed, was installed.
- If Insight is to monitor the instance and the listener mode is Forms Servlet Mode, then the Precise for J2EE Collector must be installed to monitor the Oracle Applications forms JVM.
To install Oracle Applications Tier Collector with the Precise CLI utility
- Create the Oracle Applications Tier Collector parameter file and save it to the <precise_root> folder on the main Precise FocalPoint. You can also set up this file in advance. For more information, see About Oracle Applications Tier Collector parameter file on page 83.
- Run the following command from the <precise_root> folder on the main Precise FocalPoint to execute the Precise CLI utility installation script. Use the Precise user that was created when the Precise server was defined.
Windows infra\bin\psin_cli.bat
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <insight_savvy_for_oracle_applications_installation_ parameters_file_name>
UNIX ./infra/bin/psin_cli.sh
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <insight_savvy_for_oracle_applications_installation_ parameters_file_name>
About Oracle Applications Tier Collector parameter file
You need to prepare the Oracle Applications Tier Collector parameter file by creating an XML file with elements that represent the installation parameters and inserting the appropriate values.
The following is an example of an Oracle Applications Tier Collector parameters file:
<parameters>
<parameter name="setup-process" value="apptier-OA"/>
<parameter name="setup-mode" value="install"/>
<parameter name="collector-server-machine-name" value="sun3"/>
<parameter name="instance-server-machine-name" value="sun4"/>
<parameter name="instance-name" value="OA1"/>
<parameter name="oracle-instance-name" value="ORCL"/>
<parameter name="oa-form-mode" value="forms_listener"/>
<parameter name="installation-cd-path" value="d:\"/>
</parameters>
The following table describes the elements of the parameter file. Element names marked with an asterisk (*), in this table, can be updated after installation.
Table 2-22 Elements of the Oracle Applications Tier Collector parameter file
Element | Description |
---|---|
installation-cd-path | Indicates the absolute path to the folder where the Precise v9.6 download was downloaded to. Values: String Mandatory: Yes |
setup-process | Setup process. Always apptier-OA Mandatory: Yes |
setup-mode | Setup mode. Values: install, edit, uninstall Mandatory: Yes |
collector-server-machine-name | Name of the related Oracle instance server machine. Values: String Mandatory: Yes |
instance-server-machine-name | Name of the server of the OA instance. Values: String Mandatory: Yes |
oa-real-instance-name | Name of the real Oracle Applications instance. Values: String Mandatory: No |
oa-rac-instances* | Names of the Oracle Applications RAC instances. Use two pipelines "||" as a separator between the instances. Specify only additional oracle instances. Do not specify the oracle instance specified in "oracle-instance-name". (For example: name=ORA817;server=sun3||name=OR920;server=sun5) Mandatory: No |
instance-name | A unique name of the Oracle Applications instance. This unique name helps to distinguish between several instances. Values: String Mandatory: Yes |
oracle-instance-name | The Oracle database SID name. This instance must be monitored by the Precise for Oracle Collector. Values: String Mandatory: Yes |
oa-form-mode* | The Oracle Applications forms server component work mode:
Values: Mandatory: Yes |
j2ee-instance-name | The J2EE instance that should collect the Oracle Applications forms data. Values: String Mandatory: Yes, only if the listener is |
install-insight* | Indicates whether to use Insight to collect Oracle Applications data. Values: true, false Mandatory: No, default is false. |
apptier-name | Name of the Tier. Values: String Mandatory: No |
environment-name | Name of the application. Values: String Mandatory: Yes, for a federation installation |
network-ports | OA listener ports. Use two pipelines "||" as a separator between the ports. Values: port=x||port=y (for example: port=1111||port=2222) Mandatory: No |
install-alert-customized | Values: true/false Mandatory: No Set to true to in case you want to have customized alerts metrics for this instance. |
Installing Other Tier Collectors with the Precise CLI utility
Installing Other Tier Collectors on a server enables you to sample any Tier which provides service over TCP/IP in your application. You can monitor an application that is running with an Insight Savvy for Network locally. When you want to monitor an application remotely, the Insight Savvy for Network should be installed on the remote server.
Before installing an Other Tier Collector with the Precise CLI utility, verify the following issues:
- The Insight FocalPoint was installed.
- The Precise Listener on the server(s) on which the Insight Savvy for Network Collector is to be installed, was installed.
To install Other Tier Collectors with the Precise CLI utility
- Create the Other Tier Collectors parameter file and save it to the <precise_root> folder on the main Precise FocalPoint. You can also set up this file in advance. For more information, see About Other Tier Collectors parameter file on page 83.
- Run the following command from the <precise_root> folder on the main Precise FocalPoint to execute the Precise CLI utility installation script. Use the Precise user that was created when the Precise server was defined.
Windows infra\bin\psin_cli.bat
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <insight_savvy_for_other_ installation_parameters_file_name>
UNIX ./infra/bin/psin_cli.sh
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <insight_savvy_for_other_ installation_parameters_file_name>
About Other Tier Collectors parameter file
You need to prepare the Insight Savvy for Other parameter file by creating an XML file with elements that represent the installation parameters and inserting the appropriate values.
Example:
<parameters>
<parameter name="setup-process" value="apptier-OT" />
<parameter name="instance-name" value="Other_Instance" />
<parameter name="instance-server-machine-name" value="server1" />
<parameter name="other-protocol-type" value="normal"/>
<parameter name="other-apptier-type" value="FE" />
<parameter name="other-monitor-method" value="local" />
<parameter name="other-monitor-ports" value="static" />
<parameter name="other-static-ports" value="from=50;to=90||from=100;to=120" />
<parameter name="installation-cd-path" value="d:\"/>
</parameters>
The following table describes the elements of the parameter file. Element names marked with an asterisk (*) can be updated after installation.
Table 2-23 Elements of the Other Tier Collectors parameter file
Element | Description |
---|---|
installation-cd-path | Indicates the absolute path to the folder where the Precise v9.6 download was downloaded to. Values: String Mandatory: Yes |
setup-process | Setup process. Always apptier-OT Mandatory: Yes |
setup-mode | Setup mode. Values: install, edit, uninstall Mandatory: Yes |
instance-name (component identifier field) | The unique name of the Tier that the Insight Savvy for Other Tier will monitor (for example, Citrix_Production, AS400_DB). Values: String Mandatory: Yes |
other-apptier-type* | Indicates the position and role of the Tier in your application. The options are as follows:
Values: String Mandatory: Yes |
other-protocol-type* | The network protocol for the monitored application. Two protocol types are supported:
Values: String Mandatory: Yes |
other-monitor-method | The location from where the server is monitored. Two location types are available:
Values: local, remote Mandatory: Yes |
other-monitor-ports* | Other monitor ports. Values: static (if monitoring fixed ports), dynamic (if monitoring dynamic ports) Mandatory: Yes |
instance-server-machine-name | The name of the server where you will install the Other Tier. The server name or IP address will be valid if you previously defined this server as a Precise server. Values: String. Mandatory: Yes |
other-remote-servers* | The names of the servers where you want to monitor the remote Tier. These are names whose ports will be monitored separated by two pipelines "||". Format: remote-server=server-name||remote-server=server-name Values: String. Mandatory: Yes, only if |
other-static-ports* | The TCP/IP fixed port or ports listened to by the monitored application. Use two pipelines "||" as a separator between the port ranges as follows: from=80;to=90||from=100;to=120. Do not define if the dynamic Values: String Mandatory: No. |
other-dynamic-ports-include-programs* | The dynamic ports to be monitored; they are listened to by the monitored application. These are names of programs whose ports will be monitored. The program name will be matched against the first 9 characters of the names in the list separated by two pipelines "||". Format: program=program-name||program=program-name. Do not define if the Values: String. Mandatory: No. Up to three values can be defined. |
other-dynamic-ports-exclude-programs* | The dynamic ports, listened to by the monitored application, that should NOT to be monitored. These are names of programs whose ports will NOT be monitored. The program name will be matched against the first 9 characters of the names in the list separated by two pipelines "||". Format: program=program-name||program=program-name. Do not define if the Values: String. Mandatory: No. Up to three values can be defined. |
environment-name | Name of the application. Values: String Mandatory: Yes, for a federation installation. |
show-historical-data | Indicates if historical data from the deleted instance is shown (true) or deleted (false). Values: true/false Mandatory: No. This parameter is only relevant when the setup-mode is uninstall. |
Installing an OS instance with the Precise CLI utility
Installing OS Collectors on a server enables you to sample OS instances on the server.
Before installing an OS Tier Collector with the Precise CLI utility, verify the following issues:
- The Insight FocalPoint is installed.
- The Precise Listener on the target server on which the OS Collector is to be installed, was installed. To install OS Collectors with the Precise CLI utility
- Create the OS Collectors parameter file and save it to the <precise_root> folder on the main Precise FocalPoint.
- Run the following command from the <precise_root> folder on the main Precise FocalPoint to execute the Precise CLI utility installation script. Use the Precise user that was created when the Precise server was defined.
Windows infra\bin\psin_cli.bat
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <insight_savvy_for_os_installation_parameters_file_name>
UNIX ./infra/bin/psin_cli.sh
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <insight_savvy_for_os_installation_parameters_file_name>
About OS Collectors parameter file (Precise CLI utility)
You need to prepare the Insight Savvy for OS parameter file by creating an XML file with elements that represent the installation parameters and inserting the appropriate values.
The following is an example of an Insight Savvy for OS parameters file:
<parameters>
<parameter name="setup-process" value="apptier-OS"/>
<parameter name="setup-mode" value="install"/>
<parameter name="collector-server-machine-name" value="pifa102"/>
<parameter name="instance-name" value="pifa102"/>
<parameter name="installation-cd-path" value="d:\"/>
</parameters>
The following table describes the updated elements of the parameter file.
Table 2-24 Elements of the OS Collectors parameter file
Element | Description |
---|---|
installation-cd-path | Indicates the absolute path to the folder where the Precise v9.6 download was downloaded to. Values: String Mandatory: Yes |
setup-process | Setup process. always apptier-OS Mandatory: Yes |
setup-mode | Setup mode. Values: install, edit, uninstall Mandatory: Yes |
collector-server-machine-name | Name of the server on which the OS Collector will be installed. Values: String Mandatory: Yes |
instance-name | Name of the server on which the OS Collector will be installed. Values: String Mandatory: Yes |
environment-name | Name of the application. Values: String Mandatory: Yes, for a federation installation |
install-alert-customized | Values: true/false Mandatory: No Set to true to in case you want to have customized alerts metrics for this instance. |
show-historical-data | Indicates if historical data from the deleted instance is shown (true) or deleted (false) Values: true/false Mandatory: No. This parameter is only relevant when the setup-mode is uninstall. |
Installing an extension for Siebel with the Precise CLI utility
Installing Siebel Collectors on a server enables you to sample Siebel instances on the server. A Siebel Tier Collector can be installed on all servers.
Before installing a Siebel Tier Collector with the Precise CLI utility, verify the following issues:
- The Precise for Oracle FocalPoint and Precise for Oracle Collector instance or Precise for SQL Server FocalPoint and Precise for SQL Collector instance are installed and running.
- The Precise Listener on the target server on which the Insight Savvy for Siebel Collector is to be installed was installed.
To install Interpoint for Siebel
- Create the Interpoint for Siebel parameter file and save it to the <precise_root> folder on the main Precise FocalPoint. You can also set up this file in advance. For more information, see About the Interpoint for Siebel parameter file on page 83.
- Run the following command from the <precise_root> folder on the main Precise FocalPoint to execute the Precise CLI utility installation script.
Windows infra\bin\psin_cli.bat
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <interpoint_for_siebel_installation_parameters_file_name>
UNIX ./infra/bin/psin_cli.sh
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <interpoint_for_siebel_installation_parameters_file_name>
About the Interpoint for Siebel parameter file
You need to prepare the Interpoint for Siebel parameter file by creating an XML file with elements that represent the installation parameters and inserting the appropriate values.
The following is an example of an Interpoint for Siebel parameters file:
<parameters>
<parameter name="setup-process" value="apptier-SB"/>
<parameter name="setup-mode" value="install"/>
<parameter name="collector-server-machine-name" value="srv1"/>
<parameter name="instance-name" value="EnDev"/>
<parameter name="siebel-database-server-name" value="dbsrv2"/>
<parameter name="siebel-database-instance-name" value="SBLDB"/>
<parameter name="siebel-gateway-server" value="srv2"/>
<parameter name="siebel-path" value="d:\sea752\siebsrv"/>
<parameter name="siebel-user" value="sadmin"/>
<parameter name="siebel-encrypted-password" value="ICLFAHMGHKEAII"/>
</parameters>
The following table describes the updated elements of the parameter file. Element names marked with an asterisk (*) can be updated after installation.
Table 2-25 Elements of the Interpoint for Siebel parameter file
Element | Description |
---|---|
installation-cd-path | Indicates the absolute path to the folder where the Precise v9.6 download was downloaded to. Values: String Mandatory: Yes |
setup-process | Setup process. Values: apptier-SB Mandatory: Yes |
setup-mode | Setup mode. Values: install, edit, uninstall Mandatory: Yes |
collector-server-machine-name | Name of the server the Siebel Tier will be installed on. Values: String Mandatory: Yes |
instance-name | Indicates the Siebel connection name. This name must be unique. Values: String Mandatory: Yes |
siebel-database-server-name | The server on which the Precise for Oracle Collector is running. Values: String Mandatory: Yes If using an SQL Server, this field is not required. |
siebel-database-instance-name | Indicates the Oracle or SQL Server database instance name. Values: String Mandatory: Yes |
siebel-gateway-server* | Indicates the Siebel gateway name. Values: String Mandatory: Yes |
siebel-path* | Indicates the Siebel installation path. Values: String Mandatory: Yes |
siebel-user* | Indicates the Siebel user name. Values: String Mandatory: Yes |
siebel-encrypted-password* | Password for Siebel. Values: Encrypted String. For more information, see Encrypt command on page 148. Mandatory: Yes. Alternatively the siebel-clear-password can be used, allowing you to specify a clear password instead of an encrypted string. |
install-alert-customized | Values: true/false Mandatory: No Set to true in case you want to have customized alerts metrics for this instance. |
Installing Precise for vCenter Server with the Precise CLI utility
The installation of Precise for vCenter Server can be performed using AdminPoint and by using the Precise CLI utility. For information on installing Precise for vCenter Server using AdminPoint, see the Precise Installation Guide.
Before installing Precise for vCenter Server with the Precise CLI utility, verify the following issue:
- The server on which you install Precise for vCenter Server must contain a Precise Listener
To install Precise for vCenter Server
- Prepare XML parameters file to specify the Precise for vCenter Server installation parameters.
- Prepare the log in details for the server with VMware vCenter Server.
- On the FocalPoint, run the following command from the <precise_root> folder to install the CLI utility installation script:
Windows infra\bin\psin_cli.bat
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <precise_for_vcenter_server_installation_parameters_file_name>
UNIX ./infra/bin/psin_cli.sh
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action setup
-parametersfile <precise_for_vcenter_server_installation_parameters_file_name>
About the Precise for vCenter Server parameter file
You need to prepare the Precise for vCenter Server parameter file by creating an XML file with tags that represent the installation parameters and inserting the appropriate values.
The following is an example of a server parameters file:
<parameters>
<parameter name="setup-process" value="apptier-VC" />
<parameter name="setup-mode" value="install" />
<parameter name="collector-server-machine-name" value="inf-fw-10" />
<parameter name="instance-server-machine-name" value="phy-vmtest-db1" />
<parameter name="vmware-center-user" value="VCuser" />
<parameter name="vmware-center-clear-password" value="VCpassword" />
<parameter name="vmware-center-exclude-servers" value="server=vm*|server=inf-fw-20" />
<parameter name="vmware-center-port" value="443" />
<parameter name="vmware-center-use-ssl-configuration" value="true" />
<parameter name="vmware-center-ssl-use-certificate" value="true" />
</parameters>
The parameters file is an XML file containing a list of parameters for a Precise for vCenter Server installation.
Table 2-26 Elements of the Precise for vCenter Server parameter file
Element | Description |
---|---|
setup-process | Name of the setup process. Always apptier-VC Mandatory: Yes |
setup-mode | Must be in one of the following modes:
Mandatory: Yes |
collector-server-machine-name | Name of the server where Precise is located. The name must be written in lowercase letters only. Values: String Mandatory: Yes |
instance-server-machine-name | Name of the server where the vCenter Server is located. The name must be written in lowercase letters only. Values: String Mandatory: Yes |
vmware-center-user | Name of the user who has permissions for the vCenter Server. Values: String Mandatory: Yes |
vmware-center-encrypt-password | Password of the user who has permissions for the vCenter Server. Values: Encrypted string Mandatory: Yes. Alternatively the vmware-center-clear-password can be used, allowing you to specify a clear password instead of an encrypted string. For more information, see Encrypt command on page 148. |
vmware-center-exclude-servers | Names of the servers that are excluded from the VCenter Server. Values: String separated by |. For example server=vm*|server=inf-fw-20 Mandatory: No |
vmware-center-port | Port of the vCenter Server instance. Values: Numeric Mandatory: Yes |
vmware-center-use-ssl-configuration | Indicates if SSL configuration is used. Values: (true/false). The default setting is true. Mandatory: No |
vmware-center-ssl-use-certificate | Indicates if an SSL server certificate needs to be used. Values: (true/false). The default setting is false. Mandatory: No. |
show-historical-data | Indicates if historical data from the deleted instance is shown (true) or deleted (false) Values: true/false Mandatory: No. This parameter is only relevant when the setup-mode is uninstall. |
Extricate command
Extricate CLI allows you to fetch installation related parameters. For example, if you have installed an Oracle instance in Precise, you can run extricate CLI to find all Oracle instance installation parameters. You can then use these parameters for informative purpose, and/or use the parameters to edit and modify the instance settings using CLI edit mode. For more information, see Edit & uninstall.
To use extricate CLI you should identify the related installation. This includes the following:
- For Framework installation - supply the Precise FocalPoint server name parameter and setup-process=framework
- For Precise FocalPoint installation - supply the Precise FocalPoint product code and server name parameters and setup-process=focal-<PRODUCT_CODE> (see Product Codes on page 175.)
- For instance installation - supply the instance name, and instance/collector server name parameters and setup-process=apptier-<TECHNOLOGY_CODE> (see Technology Codes on page 174.)
Windows infra\bin\psin_cli.bat
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action extricate
[-parametersfile <path_to_input_parameters_file>] [-parameter <name=value>]
[-output-file <file>]
UNIX ./infra/bin/psin_cli.sh
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action extricate
[-parametersfile <path_to_input_parameters_file>] [-parameter <name=value>]
[-output-file <file>]
For example:
infra\bin\psin_cli.bat
-i3-user admin
-i3-clear-password admin
-action extricate
-parameter setup-process=apptier-OR
-parameter collector-server-machine-name=poolsun5
-parameter instance-name=ORCL
The output will be done to an XML parameters file which is created by the CLI.
Table 2-27 Elements of the Extricate command parameters file
Element | Description |
---|---|
i3-user | See Authenticate to CLI Utility on page 8. |
i3-encrypted-password | See Authenticate to CLI Utility on page 8. |
action | Values: always extricate Mandatory: Yes |
parameter | Specify parameters to identify the related installation. Mandatory: Yes |
parameters-file | Specify the parameters to identify the related installation. The parameters can be specified in the command line as arguments and in a parameters file in the following format: <parameters> |
output-file | Path to a file that will be created. The file will contain the installation related parameters that are extracted. Values: String Mandatory: No. If this is omitted, the CLI utilities will set the path for the output file and will notify you of its location. |
Edit & uninstall
Using CLI you can install, edit, and uninstall components in Precise. Editing an installation allows you to modify its settings. For example - change Precise password used for Oracle instance, or change instrumentation folders for Web instance.
To edit an installation
Use the Extricate command. For more information, see Extricate command.
Update the related parameters in the parameters file. Run CLI setup using parameter setup-mode=edit. For more information, see Installation with Precise CLI on page 9.
To uninstall an installation
Prepare an input XML file with the required parameters to identify the installation. For more information, see Extricate command.
Run CLI setup using parameter setup-mode=uninstall. For more information, see Installation with Precise CLI on page 9.
Installing a new instance while keeping historical data from an old instance
There are cases in which you want to install a new instance and use the historical data from an old instance (this might be required in case you have moved or renamed your instance).To do so, use the old instance ID for the new installed instance. The following procedure describes how to do this.
Data related to deleted instances may be deleted permanently by the PMDB maintenance process. If you intend to use the deleted instance's data, you should check that it is not deleted by the PMDB. You can see if the check box of the purge parameter in the PMDB Maintenance (Weekly) process is not marked.
Old instance data is kept as part of the related FocalPoint schema. This means that the instance historical performance data is only kept while the FocalPoint is installed. If you uninstall the related FocalPoint, you no longer can recover the instance historical performance data.
To install a new instance using an uninstalled instance ID
Trying to install an instance, while using an ID that was not deleted will cause an error (You will also get this error when you try to install an instance with an ID of an unmonitored instance). Therefore, if the old instance is not yet uninstalled, uninstall it now without historical data using the GUI or CLI.
From the <precise_root> folder on the main Precise FocalPoint, run the following query command to retrieve the instance ID:
Windows infra\bin\psin_cli.bat
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action get-instance-id
-technology <technology_code>
-instance <instance_name>
-server <server_name>
UNIX ./infra/bin/psin_cli.sh
-i3-user <user_name>
{-i3-encrypted-password <encrypted_password> | -i3-clear-password <clear_password>}
-action get-instance-id
-technology <technology_code>
-instance <instance_name>
-server <server_name>
Table 2-28 Elements of the Retrieve instance ID query commandElement Description i3-user See Authenticate to CLI Utility on page 8. i3-encrypted-password See Authenticate to CLI Utility on page 8. action always get-instance-id
Mandatory: Yes
technology Values: Technology code. For more information, see Technology Codes on page 174.
Mandatory: Yes
instance The instance name.
Values: String
Mandatory: Yes
server The instance server name.
Values: String
Mandatory: Yes
- If there are several instances with the same name, the CLI utility will provide the latest instance ID in the output. A non-deleted instance will appear as installed.
- Create CLI parameters file to install the new instance. Add the
recovered-instance-id
parameter to the parameters file with the instance ID that was detected and run the CLI to install the new instance. For more information, see Installing a Tier with the Precise CLI utility.
Precise. Performance intelligence from click to storage. Learn more > >
Windows | i nf r a\bin\ p sin_cli.bat |
UNIX | ./in f ra/bin/ p sin _ cli.sh |
Values: true/false
Mandatory: No
Set to true to in case you want to have customized alerts metrics for this instance.
Indicates whether to use Insight to collect Oracle Applications data.
Values: true, false
Mandatory: No, default is false.