Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Table 8-1 Data filtering configuration parameters

ParameterDescription
filteringEnabled

Activates and deactivates data filtering.

Type: Boolean

Default value: true

filteringMaxInvocationTrees

The maximum number of entry points to keep, based on service time.

Type: Integer

Default value: 100

Info

For more information, see About the data filtering stages.


filteringPercent

The minimum percent value of the entry point’s service time necessary to keep a node.

Type: Integer

Default value: 1

Info

For more information, see About the data filtering stages.


filteringThreshold

The minimum work time value (milliseconds) threshold to keep a node.

Type: Integer

Default value: 5

Info

For more information, see About the data filtering stages.


Keeping exceptions of filtered invocations

...

Anchor
Table82
Table82
Table 8-2 Configurable parameters in the findings-config.xml file

ParameterDescription
max-findings-to-display

The maximum number of findings to be displayed in the user interface.

Type: Integer

Default value: 7

timeout-in-seconds

The time limit (in seconds) that the findings query will run.

Type: Integer

Default value: 20

enabled   

 

The finding will only be displayed if it is enabled.

Type: Boolean

Default value: true

tab

The finding will only be displayed in the specific tab (activity or dashboard) if it is enabled.

Type: Boolean

Default value: true

topN-to-display

The maximum number of times a specific type of findings will be displayed (with different contexts).

Type: Integer

Default value: 2

thresholds

Each finding’s severity is calculated based on finding specific thresholds.

Type: Integer

Anchor
AboutConfigHTTP
AboutConfigHTTP
About configuring HTTP query parameters and Java method arguments capturing

...

Table 8-3 Minimum permissions for the <i3_root> directory for the application server user

DirectoryMinimum permissions
<i3_root>/distributionread, execute
<i3_root>/infraread, execute
<i3_root>/javaread, execute
<i3_root>/productsread, execute
<i3_root>/supportread, write, execute
<i3_root>/logsread, write, execute

The following table shows the minimum permissions that you can set for the application server user or group for the <i3_root>/products/j2ee directory.

Table 8-4 Minimum permissions for the <i3_root>/products/j2ee directory for the application server user

DirectoryMinimum permissions
<i3_root>/products/j2eeread, execute
<i3_root>/products/j2ee/archiveread, execute
<i3_root>/products/j2ee/cacheread, execute
<i3_root>/products/j2ee/configread, write, execute
<i3_root>/products/j2ee/installread, execute
<i3_root>/products/j2ee/libread, execute
<i3_root>/products/j2ee/samplesread, execute
<i3_root>/products/j2ee/supportread, execute
<i3_root>/products/j2ee/binread, execute
<i3_root>/products/j2ee/classesread, execute
<i3_root>/products/j2ee/etcread, write, execute
<i3_root>/products/j2ee/installedread, execute
<i3_root>/products/j2ee/logsread, write, execute
<i3_root>/products/j2ee/smartlinkread, write, execute
<i3_root>/products/j2ee/tacread, write, execute

Anchor
AboutMonitoringSettings
AboutMonitoringSettings
About monitoring settings for a J2EE remote instance

...

  1. Delete this node inside the InstrumenterConfigList.xml file.
  2. Restart the JVM.
Precise. Performance intelligence from click to storage. Learn more > >

...


IDERA Website | Products | Buy | Support | Community | About Us | Resources | Legal