- In the My Infrastructure tab, click Add System / Network Device.
- Enter Type a descriptive name for the server in the Display name in Uptime Infrastructure Monitor field.
- Enter Optional. Type a description of the system in the Description field (optional).
- Select Net-SNMP v2 or Net-SNMP v3 from the Type of System / Device dropdown list.
- Enter Type the host name of the system in the Host Name field.
- If you selected Net-SNMP v2 in step 4, enter type additional information in the following fields:
- SNMP Port
- . Type the port on which the Net-SNMP instance is listening.
- Read Community
...
- . Type a string that acts like a user ID or password and provides access to the Net-SNMP instance.
- If you selected Net-SNMP v3 in step 4, enter type additional information in the following fields:
- SNMP Port
- . Type the port on which the Net-SNMP instance is listening.
- Username
- . Type the name required to connect to the Net-SNMP instance.
- Authentication Password
...
- . Type the password required to connect to the Net-SNMP instance.
- Authentication Method
...
- . Optional. MD5 or SHA
...
- .
...
- Privacy Password
...
- . Type the password used to encrypt information traveling between
...
- UIM and the Net-SNMP instance.
...
- Privacy Type
...
- . Optional. Select the encryption protocol for information traveling between
...
- UIM and the Net-SNMP instance: DES or
...
- AES
...
- .
- Click Save and then Close.
...
- ,
...
- and
...
- In the My Infrastructure tab, click the name of the pSeries server that contains the LPAR that you want to monitor. A new window containing information about the system will appear.
- Click the Info tab and then click Logical Partitions. A list of LPARs will appear in the sub-panel.
- Click the Add to Uptime button beside the LPAR that you want to add. The Add System window will appear.
- If necessary, you can change any of the following options: Display name in Uptime
Description Group
Service Group
- Click Save to add the LPAR to Uptime Infrastructure Monitor.
...
Title
...
Creator
...
Modified
...
How to display the NetFlow dashboard using IE
...
...
Nov 19, 2015
...
/var/adm/messages kernel: cdrom: open failed
...
...
Nov 19, 2015
...
Suppress Connection Warnings from the Agent in /var/adm/messages
...
...
Nov 12, 2015
...
Monitor Disk Mounting in Active / Passive Cluster Nodes
...
...
- then click Close.