Precise for J2EE v9.0 introduces the " Monitor Settings " dialog box to the user interface. This dialog box is recommended for configuring most of the common Precise for J2EE instrumentation. For details, see the About configuring Precise for J2EE settings section in the Precise for J2EE User Guide. In some cases, however, it may be preferable to manually perform specific instrumentation. This section describes these cases.

...

  1. Open the collector.xml file in the registry folder. Use this file to define a filter on an exception class name, using regular expressions.
  2. Edit the following tag:
    <exceptionFilterByName></exceptionFilterByName>
    The default filter tag is:
    <exceptionFilterByName>.*</exceptionFilterByName>
  3. Run the relevant CLI command as it appears in step 3 of Instance registry or Cluster registry.

Anchor
AboutConfiguringDataFiltering
AboutConfiguringDataFiltering
About configuring data filtering

To reduce the quantity of collected data and propagate mainly meaningful data, a filtering mechanism is used. This mechanism is used to filter nodes and invocations before loading the data into the PMDB.

...

ParameterDescription
max-findings-to-display

The maximum number of findings to be displayed in the user interface.

Type: Integer

Default value: 7

timeout-in-seconds

The time limit (in seconds) that the findings query will run.

Type: Integer

Default value: 20

enabled    


The finding will only be displayed if it is enabled.

Type: Boolean

Default value: true

tab

The finding will only be displayed in the specific tab (activity or dashboard) if it is enabled.

Type: Boolean

Default value: true

topN-to-display

The maximum number of times a specific type of findings will be displayed (with different contexts).

Type: Integer

Default value: 2

thresholds

Each finding’s severity is calculated based on finding specific thresholds.

Type: Integer

...

  1. Delete this node inside the InstrumenterConfigList.xml file.
  2. Restart the JVM.

...


Scroll Ignore
scroll-pdftrue
scroll-officetrue
scroll-chmtrue
scroll-docbooktrue
scroll-eclipsehelptrue
scroll-epubtrue
scroll-htmltrue
Newtabfooter
aliasIDERA
urlhttp://www.idera.com
 | 
Newtabfooter
aliasProducts
urlhttps://www.idera.com/productssolutions/sqlserver
 
Newtabfooter
aliasPurchase
urlhttps://www.idera.com/buynow/onlinestore
 | 
Newtabfooter
aliasSupport
urlhttps://idera.secure.force.com/precise/
 | 
Newtabfooter
aliasCommunity
urlhttp://community.idera.com
 
|
 
Newtabfooter
aliasResources
urlhttp://www.idera.com/resourcecentral
 | 
Newtabfooter
aliasAbout Us
urlhttp://www.idera.com/about/aboutus
 
Newtabfooter
aliasLegal
urlhttps://www.idera.com/legal/termsofuse